• Title/Summary/Keyword: Glass fibers

Search Result 360, Processing Time 0.024 seconds

Fabrication and Applications of Polyphenylene Sulfide (PPS) Composites: A Short Review (폴리페닐렌설파이드(PPS) 복합소재 제조 및 응용)

  • Choi, Minsik;Lee, Jungrok;Ryu, Seongwoo;Ku, Bon-Cheol
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.91-100
    • /
    • 2020
  • Polyphenylene sulfide (PPS) is a semi-crystalline engineering thermoplastic resin that has outstanding thermal stability, mechanical strength, inherent flame retardancy, chemical resistance, and electrical properties. Due to these outstanding properties, it is preferred as a matrix for composite materials. Many studies have been conducted to produce composites with carbon fibers and glass fibers to improve mechanical properties and provide functionality of PPS. In this review paper, we report a brief introduction to the fabrication and applications of PPS composites with carbon nanotubes, graphene, carbon fibers, and glass fibers.

Thermal Characteristics of Hybrid Composites for Application to Surfboard (서프보드 적용을 위한 하이브리드 복합재료의 열적 특성)

  • Kim, Yun-Hae;Lee, Jin-Woo;Park, Chang-Wook;Park, Soo-Jeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.351-355
    • /
    • 2014
  • Today, carbon fibers are used as heating elements. Carbon fibers are generally used to reinforce composite materials because they are lightweight and have a high strength and modulus. Carbon fiber reinforced composite materials are used for aerospace, automobile, and wind turbine blade applications. This work explored the possibility of using carbon fiber reinforced composite materials as self heating materials. The temperatures of the carbon fiber reinforced composites were measured. These results verified that the carbon fiber reinforced composite materials could be used as heating elements. A glass fiber was laminated using various methods. The thermal characteristics of the composites were evaluated. This confirmed that the generation of heat varied according to the lamination thicknesses of the carbon fiber and glass fiber. As the number of carbon fiber laminations increased, the heat-generating temperature increased. In contrast, as the number of glass fiber laminations increased, the amount of heat decreased. The generation of heat and ability to remain warm could be controlled by controlling the carbon fiber and glass fiber laminations.

Impact Properties of Glass/Kevlar Hybrid Composites (유리/케블라 하이브리드 구조로 강화된 복합재료의 충격 거동)

  • Joo, Ki-Ho;Ryou, Han-Sun;Chung, Kwan-Soo;Kang, Tae-Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.191-194
    • /
    • 2005
  • Impact properties of glass/Kevlar hybrid composites which have 3-D braided structures were studied. Results were compared to those of composites made of only glass fibers where the same epoxy resin were used as matrix. Absorbed impact energies evaluated through the combination of the data from the impact tester and high speed camera were compared to each other. In order to see the difference between the damaged area distribution CCD camera captures were performed.

  • PDF

The Study on Physical Properties and Applicability of Material of Polyamide-66/Glass Fiber Blends Composition to the Eyewear Frame (Polyamide-66/Glass fiber 블렌드 조성물의 물리적 특성 및 안경테 소재로써의 적용성에 관한 연구)

  • Son, Jin-Young;Lee, Ji-Eun;Choi, Kyung-Man;Bae, Yu-Hwan;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.365-371
    • /
    • 2013
  • Purpose: In this study, we evaluated the physical and thermal properties of the compositions made by blending glass fiber (GF) of different contents into glass fiber polyamide-66, and investigated if the compositions applying to the glasses frame to replace the TR-90, which is polyamide-12 resin used as an injection-type spectacle frame material. Methods: To investigate the characteristics change of polyamide-66 (PA-66) compositions with the change of the content of glass fibers, we produced a composition of the content by using a twin-screw extruder. The mechanical strength of the composition production was measured and coating properties as well as cutting processability were evaluated. We evaluated the applicability of the glasses frame by comparison the results of new compositions with characterizations of traditional TR. Results: For the results of the characterization of Polyamide-66/GF composition, we found that the higher increase of content of the glass fiber, the less mold shrinkage rate, and the mechanical strength was increased. Tensile strength increased from $498kg/cm^2$ for 0 wt% of the content of the glass fibers to $849kg/cm^2$ for 30 wt% of the content of the glass fibers. As a result of a coating evaluation, the strength of coating was 4B in the GF 5wt% and 5B, which was extremely good coating characteristics, in the over than GF 5 wt%. Conclusions: In case that 30 wt% of the glass fiber was blended, the mechanical strength was greatly improved, the hardness was increased, injection temperature increased due to increase of the viscosity, and the flow mark of the product may occur. The paint coating of PA-66 blended with glass fiber was all excellent. With general evaluating physical properties and workability properties it was determined that around 10 wt% of the content of the glass fibers was possible to apply a spectacle frame.

Recycling of Separate Glass Fiber from Waste Printed Circuit Boards Using Attrition Mill and DMF (어트리션 밀과 DMF 용매를 이용한 폐 인쇄회로기판에서 분리된 재생 유리섬유의 재활용)

  • Kim, Jong-Seok;Lee, Jae-Cheon;Jeong, Jin-Ki
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.894-899
    • /
    • 2012
  • In recent years, recycling process has come to be necessary for separating metals, glass fibers and polymer from WPCBs (waste printed circuit boards) due to an increasing amount of electronic device waste. In this study, dimethylformamide (DMF) and attrition mill reactor were used to separate the component such as metals, glass fiber and epoxy resin from WPCBs. Separation of glass fiber from WPCBs was carried out under stirring rates 300~600 revolution per minute (rpm) for 1~2 h as the various agitator. The recycled glass fibers (RGF) were analyzed by thermogravimetric analyzer (TGA) for degree of separation of epoxy resin in the WPCBs. The degree of separation of epoxy resin of WPCBs increased in attrition mill agitator as a mechanochemical process for recycling WPCBs. The RGF separated in the WPCBs was applied as a reinforcement in the RGF/unsaturated polyester composites to reuse as a reinforcement.

Medical Surveillance of Glass Fiber Workers in Korea (유리섬유 제조업체 근로자의 건강장해)

  • Lee, Se-Wi;Kim, Kyoo-Sang;Choi, Jung-Keun;Kim, Yang-Ho;Kang, Seong-Kyu;Choi, Kyuong-Suk;Moon, Young-Hahn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.2 s.53
    • /
    • pp.187-198
    • /
    • 1996
  • The industrial use of MMMF(man-made mineral fibers), has been increasing, particularly since the banning of most asbestos products. Fibrous minerals can cause health abnormalities currently associated with occupational exposure to glass fiber. This study was conducted to evaluate health risks of glass fiber manufactory workers within the country. We examined questionaries, physical examination including auscultation, chest x-ray, pulmonary function test for 488 male workers, to go through their dermal itching symptoms and respiratory evaluation. we had the results as follows. 1. In 45% of the workers itching had been expressed at their entrance. At that time we was investigating, 18.5% had itching, and most of them complained it when they fall asleep and night. The Sequent itching site is waist and groin, upper and lower extremity in order, and it had been expressed mainly during summer and winter. 2. As the results of ventilatory functions test, 6.0% were obstructive type, 1.0% were restrictive type. So, glass fiber exposures should be controlled or elimination by protective devices in the workplace. 3. The means of FVC, $FEV_1,\;FEV_1%$ were in normal range. As the comparison of ventilatory functions by age groups, MMF was decreased significantly for the group, 50 years old and more than other groups. And the comparison by the serving periods at glass fiber producing factory, MMF was decreased for the workers had worked for $11\sim15$ years. Therefore, MMF be more sensitive index in the evaluation of ventilatory impairments caused by glass fiber workers.

  • PDF

Preparation and Properties of Glass Fiber-Reinforced Poly(olefin ketone) Composites (유리섬유 강화 폴리올레핀케톤 복합재료의 제조 및 특성에 대한 연구)

  • Cho, Hae-Souk;Chung, Jae-Seung;Baek, Seung-Jo;Choi, Won Jae;Kim, Jin-joo;Yoon, Sung Kyun;Lee, Jong-Chan
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.339-343
    • /
    • 2012
  • Poly(olefin ketone) terpolymer having excellent mechanical properties was synthesized and composite materials of poly(olefin ketone) containing polyurethane/amino silane functionalized glass fibers were prepared. The compatibilities between the functionalized glass fiber and the polymer were characterized by observing the fracture surfaces of the composites using scanning electron microscopy (SEM). Mechanical properties of composites with different contents, diameters, lengths, and binders of glass fibers were also studied using universal testing machine (UTM). The introduction of suitably functionalized glass fiber into the poly(olefin ketone) produces composite materials having excellent mechanical properties and they are very promising alternative materials for the engineering plastic applications.

Drilling Characteristics of Glass Fiber Reinforced Polyester (유리섬유 강화 폴리에스터의 드릴가공 특성)

  • 김성일
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.90-95
    • /
    • 2000
  • Today fiber composite materials are routinely used in such wide applications as ships automobiles aircraft space vehi-cles containers sporting goods and appliances. The current knowledge of machining glass fiber reinforced polyester com-posites unfortunately is inadequate for its optimum utilization in many applications. Therefore This paper deals with drilling characteristic of glass fiber reinforced polyester composites. In the drilling of glass fiber reinforced polyester the quality of the cut surfaces is strongly dependent on the drilling parameters. drilling tests were carried out on glass fiber reinforced polyester using standard HSS tools. The material containing random chopped strand fibers and woven roving was fabricated by hand lay-up The entrance and exit surface of the holes was examined. The cutting force was also mea-sured to analyze the drilling characteristics,.

  • PDF

S-2 Glass Fiber (Super Tensile Strength 유리섬유 방사연구)

  • Sung, Wan;Lee, Jae-Rak;Chang, Haeng-Jong;Kim, Yeong-Geun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.212-215
    • /
    • 2000
  • For the production of high strength constructional glass reinforced plastics and various composite materials continuous glass fibers of high strength and increased modulus of elasticity are used. As is known, the glasses with highest strength were obtained in magnesia alumosilicate and magnesia lime-alumosilicate systems when introducing oxides of titanium and zirconium, boric anhydride, etc. in some cases. The experimental investigations have shown that some glass compositions are characterized by the ratio viscosity/crystallization which is favourable for glass fiber drawing process that permits the attainment of high strength level at the conditions of high temperature glass melting and formation.

  • PDF

Effect of Sampling and Analytical Methods on the Fibrous Materials from the Ground Water (시료 채취 조건 및 검사방법에 따른 지하수내 섬유상 물질 검출 양상에 관한 연구)

  • Kim, Ji-Yong;Kim, Jung Ran;Cheong, Hae-Kwan;Lim, Hyun-Sul;Paik, Nam-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.209-222
    • /
    • 1997
  • Authors surveyed the ground water near the waste disposed from a fiberglass production factory to confirm the presence of glassfiber in the water and to determine the effect of sampling conditions and storage on the recovery of fibrous materials in the ground water. Sample was collected at every 4 hours for 48 hours consecutively. After finishing the 48 hours sample, water sampling was done from each tap after repeated turning on and off the water for 30 seconds at each time. Sample was collected in the two 1.5 liter polyethylene bottle after vigorously shaking the bottle with the same water several times with the flowing tap water. At each paired sample, one bottle was stored stand still at room temperature, and the other sample was filtered immediately after sampling. Water was filtered on the Mixed Cellulose Ester filter with negative pressure. Each sample was divided into upper and lower layer. The other bottle was stored at room temperature standstill for 7 days and filtered in the same fashion as the other pair of sample did. Each MCE filter was divided into 4 pieces and one piece was treated with acetone to make it transparent. Each prepared sample was observed by two researchers under the light and polarizing microscopy, scanning electron microscopy and energy dispersive X-ra microanalysis. Fibers were classified by the morphology and polarizing pattern under the polarizing microscope, and count was done. 1. There was a significant fluctuation in number of the fibers, but there was no specific demonstrable pattern. 2. Non-polarizing fibers frequently disappeared after 7 days's storage. But cluster of fibers were found at the wall of the same container by scratching technique. 3. Polarizing fibers were usually found in between the filter and the manicure pasted area. Possible explanations for this phenomenon will be that either these fibers are very light or have electronic polarity. Hence, these fibers are not able to be attached on the surface of slide glass. 4. Under the scanning electron microscopic examination, the fibers which are not refractive under the light microscopy were identified as glassfiber. Other fibers which is refractive under the polarizing microscopy were identified as magnesium silicate fibers. It is strongly suggested that development of standardized method of sample collection and measurement of fibrous material in the water is needed.

  • PDF