• Title/Summary/Keyword: Glass Filter

Search Result 222, Processing Time 0.022 seconds

Exposure Assessment of Solvents and Toluene Diisocyanates among Polyurethane Waterproofing Workers in the Construction industry (건설현장 우레탄 방수작업자의 휘발성 유기화합물 및 톨루엔 디이소시아네이트 노출평가)

  • Park, Hyunhee;Hwang, Eunsong;Ro, Jiwon;Jang, Kwangmyung;Park, Seunghyun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.134-152
    • /
    • 2020
  • Objectives: The objective of this study was to evaluate volatile organic compounds (VOCs) and toluene diisocyanates (TDIs) exposure among polyurethane waterproofing workers in the construction industry. Methods: Task-based personal air samplings were carried out at seven construction sites using organic vapor monitor for VOCs (n=88) and glass fiber filters coated with 1-(2-pyridyl)piperazine(1-2PP) for TDIs (n=81). The concentration of VOCs and TDIs were shown for four different work types(mixing paint, primer roller painting, urethane resin spread painting, painter assistant) at five different worksites (rooftop, ground parking lot, piloti, bathroom, and swimming pool). The two TDI sampling methods (filter vs impinger) were evaluated in parallel to compare the concentrations. Results: The geometric mean(GM) concentration of VOCs Exposure Index (EI) was highest for primer roller painting (1.4), followed in order by, urethane resin spread painting (0.85), mixing paint (0.53), and painter assistant (0.35) by work types. The GM of VOCs EI was highest for bathroom (1.4) followed in order by, swimming pool (0.85), piloti (0.89), ground parking lot (0.82) and rooftop (0.57) by worksites. The GM of 2,4-/2,6-TDI concentration was 0.052 ppb and 0.432 ppb each. There was no statistical difference in TDIs concentrations among worksites. The concentration of 2,6-TDI was ten times higher than that of 2,4-TDI. The concentration of 2,6-TDI by impinger method was 5.7 times higher than that by filter method. Conclusions: In this study, we found 38.6% of the VOCs samples exceeded the occupational exposure limits and 19.8% of the 2,6-TDI samples exceeded 1 ppb among polyurethane waterproofing workers. The most important determinants that increase the concentration of VOCs and TDIs was indoor environment and primer painting work.

Change in Quality of Mixed Juice of Fruits and Vegetables by Aseptic Treatment and Packing with Nitrogen Gas during Storage (제균처리와 질소가스포장에 따른 혼합과채주스의 저장 중 품질 변화)

  • Kim, Su-Yeun;Yoon, Young-Bean;Choi, Eon-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.1271-1277
    • /
    • 2000
  • The extracts from tomatoes, apples, carrots, mallows, watercreses+pine needles, Angelica keiskei Koiz, jujubes and lemons were selected and mixed at the ratio of 3 : 3 : 3 : 1/2 : 1/2 : 1/2 : 1/2 : 1/5 on the basis of sensory evaluation. The mixed extracts were divided into three lots and treated as follows. The first lot was heated for 15 sec at $96^{\circ}C$ without centrifugation and filtration, the second filtered through a ultramembrane filter. For the third one, the ultrafiltrate combined with autoclaved retentates on the membrane filter and the previous centrifugal precipitation. The mixed juices were stored in the glass bottles with atmosphere or in film package with nitrogen gas. And then they were stored at $4^{\circ}$ and $20^{\circ}C$. During storage the treated juices showed $pH\;4.07{\sim}4.10$, titratable acidity $66.35{\sim}84.08$, soluble solid $7{\sim}9^{\circ}Brix$, reducing sugar $5.42{\sim}6.97%$, glucose $1.96{\sim}2.30%$ and fructose $3.46{\sim}4.14%$. The ultrafiltered juices showed yellow color, different from orange color of other treatment lots. Peroxidase activity and microbial population were inhibited by thermal treatment and ultrafiltration. The browning effects of the mixed juice of fruits and vegetables during storage were caused by ascorbic acid oxidation and non-enzymatic browning reaction, which could be reduced by change and packing with nitrogen gas instead of atmosphere inside bottles.

  • PDF

Source Identification of Ambient Size-by-Size Particulate Using the Positive Matrix Factorization Model on the Border of Yongin and Suwon (PMF 모델을 이용한 용인-수원경계지역에서의 부유분진의 크기별 오염원 확인)

  • Oh, Mi-Seok;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.2
    • /
    • pp.108-121
    • /
    • 2009
  • The suspended particulate matters have been collected on membrane filters and glass fiber filters by an 8-stage cascade impactor for 2 years (Sep. 2005${\sim}$Sep. 2007) in Kyung Hee University-Global Campus located on the border of Yongin and Suwon. The 20 chemical species (Al, Mn, Si, Fe, Cu, Pb, Cr, Ni, V, Cd, Ba, $Na^+$, ${NH_4}^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, ${NO_3}^-$, and ${SO_4}^{2-}$) were analyzed by an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on these chemical information, the PMF receptor model was applied to identify the source of ambient size-by-size particulate matters. The receptor modeling is the one of the statistical methods to achieve resonable air pollution management strategies. A total of 10 sources was identified in 9 size-ranges such as long-range transport, secondary aerosol, $NH_{4}NO_{3}$ related source, coal combustion, sea-salt, soil, oil combustion, auto emission, incineration, and biomass burning. Especially, the secondary aerosol source assorted in fine and coarse modes was intensively studied.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Collecting of Hanji Fibrous Sludge with Surfactant (계면활성제를 이용한 한지 섬유질 슬러지의 제거)

  • Choi, Hee-Seon;Kim, Tai-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.167-172
    • /
    • 2001
  • The technique that could collect efficiently the hanji fibrous sludge from wastewater using surfactants was developed. When fibrous sludge of which concentration was about 80mg/L, was floated and collected, the optimum concentration of sodium oleate, the pore size of glass filter and the air flow rate were 10mg/L, $5-10{\mu}m$ and 200mL/min., respectively. The behavior of sodium oleate might be interfered by polyvalent cations such as $Ca^{2+}$. But when the concentration of $Ca^{2+}$ was less than 100mg/L, the interference effect did not appear. And when a typical cationic surfactant, cetyltrimethylammonium bromide(CTAB), was used, the collecting yield was less than that of sodium oleate, and the amount of foam was higher than sodium oleate. When 1mg/L of CTAB was added to the hanji sludge sample contained 1mg/L of $PAMID^{(R)}$, a dispersant, fibrous sludge was effectively coagulated, the flotation time was very short and the collecting yield was above 95%. But in the case, sodium oleate was inefficient.

  • PDF

Occurrence of Phthalates in Indoor Dust from Children's Facilities and Apartments in Seoul

  • Kim, Ho-Hyun;Lim, Young-Wook;Yang, Ji-Yeon;Shin, Dong-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.382-391
    • /
    • 2009
  • The aim of the study was to assess the levels in typical central borough of phthalate exposure by monitoring children's facilities (19 kindergartens and 21 elementary schools) and households (17 old apartments and 22 new apartments) via sampling indoor floor dust. A vacuum cleaner specifically prepared for sampling dust was attached to a filter of a vacuum cleaner dust collecting container. During the sample preparation process, containers made of glass were used and analysis was performed using GC-MSD. The mean concentration of DEHP was $412{\mu}g/g$, DnBP was $24{\mu}g/g$, and BBzP was $10{\mu}g/g$ dust. The indoor characteristics including floor, wall materials, years after construction, water leakage history for the past three years, and ventilation were also examined to categorize phthalate esters from the dust samples. From the flooring and wallpaper materials of kindergartens and elementary schools, DEHP in the dust sample appeared at a statistically significant level (p<0.05) when PVC materials were present. DEHP in the indoor dust also increased significantly (p<0.01) during the construction period. The daily intake of DEHP measured from indoor dust was 0.08~$19.7{\mu}g/kg/day$ for children and 0.02~$1.1{\mu}g/kg/day$ for adults (women). The results clearly revealed that phthalate exposure is greater in children than in adults (women) due to the indoor dust.

Simultaneous Determination of Residual Synthetic Antimicrobials in Animal Muscles by High Performance Liquid Chromatography (액체 크로마토그라피를 이용한 동물 근육조직 중의 합성항균제 동시 분석)

  • 정규생;채명식;김창동;김종배
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.1
    • /
    • pp.25-35
    • /
    • 1993
  • This study is conducted to deyelop more conyenient simultaneous determination method by HPLC for mixed antimicrobial agents (sulfamerazine; SMR, sulfamethazine; SMT, sulfamonomethoxine; SMMX, sulfadimethoxine; SDMX, sulfaquinoxaline; SQX, furazolidone; FZ, zolene; ZOL and ethopabate; EPB in muscles of boline, pork and chicken. The drugs were extracted by dichloromethane and water. The extract, after solyent eyaporation, was partitioned in hexane/water and water/dichloromethane. The dichloromethane layer was filtrated with anhydrous $Na_5S0_4\;in\;_3G_3$ glass filter and was eyaporated to dryness. The residue was dissoIYed in mobile phase. The test solution analyzed by HPLC. The chromatograpic conditions were as follows; Column-Spheri 5 RP-8($4.6{\times}220,\;5\;{\mu}$), Wayelength-270 nm, Mobile phase-acetonitrile: 0.005 M oxalic acid (22 : 78). The ayerage recoyeries of drugs from muscles of boline, pork and chicken spiked standard solution were approximately 74~99%, 73~99% and 75~96%, respectiyely. The limits of detection were 5 ppb for SMR, SMT, SMMX, SDMX and EPB, and 8 ppb for SQX, FZ and ZOL.

  • PDF

Development of a Flatbed Scanner for Reflection Infrared Photography (반사 적외선 사진을 위한 평판 스캐너의 개발)

  • Choi, Young-Ho;Hwang, Min-Ku;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.57-66
    • /
    • 2011
  • At this time, digital cameras are used in art and forensic science. However, the digital camera has some limitations which need to understand of photograph and lighting. It is a useful paper to make an infrared flatbed scanner. The following processes offer an infrared flatbed scanner development. First, the infrared flatbed scanner changes visible fluorescent lamp to infrared LED. Second, it equips a long-pass filter, which is available to pass over 810nm wavelength, on the glass to complete the optimal infrared flatbed scanner. In addition, it must copy from digital camera to computer directly. The infrared digital camera has disadvantage to always irradiate infrared lamp. Because of difference between visible length and infrared length characteristic, they have different focal distance. This devised scanner for solving mentioned problems does not need to irradiate infrared lamp, and there is not a problem about focal point because the depth of field of flatbed scanner is minimum 2mm. Lastly, the infrared flatbed scanner can make high resolution which is 12,800dpi unlike digital camera. Accordingly, the infrared scanner looks forward to be used in many field of study.

Comparison of Mutagenic Activities of Various Ultra-Fine Particles

  • Park, Chang Gyun;Cho, Hyun Ki;Shin, Han Jae;Park, Ki Hong;Lim, Heung Bin
    • Toxicological Research
    • /
    • v.34 no.2
    • /
    • pp.163-172
    • /
    • 2018
  • Air pollution is increasing, along with consumption of fossil fuels such as coal and diesel gas. Air pollutants are known to be a major cause of respiratory-related illness and death, however, there are few reports on the genotoxic characterization of diverse air pollutants in Korea. In this study, we investigated the mutagenic activity of various particles such as diesel exhaust particles (DEP), combustion of rice straw (RSC), pine stem (PSC), and coal (CC), tunnel dust (TD), and road side dust (RD). Ultra-fine particles (UFPs) were collected by the glass fiber filter pad. Then, we performed a chemical analysis to see each of the component features of each particulate matter. The mutagenicity of various UFPs was determined by the Ames test with four Salmonella typhimurium strains with or without metabolic activation. The optimal concentrations of UFPs were selected based on result of a concentration decision test. Moreover, in order to compare relative mutagenicity among UFPs, we selected and tested DEP as mutation reference. DEP, RSC, and PSC induced concentration-dependent increases in revertant colony numbers with TA98, TA100, and TA1537 strains in the absence and presence of metabolic activation. DEP showed the highest specific activity among the particulate matters. In this study, we conclude that DEP, RSC, PSC, and TD displayed varying degrees of mutagenicity, and these results suggest that the mutagenicity of these air pollutants is associated with the presence of polycyclic aromatic hydrocarbons (PAHs) in these particulate matters.

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.