• Title/Summary/Keyword: Ghost removal

Search Result 9, Processing Time 0.019 seconds

Noise removal or video sequences with ,3-D anisotropic diffusion equation (3차원 이방성확산 방정식을 이용한 동영상의 영상잡음제거)

  • Lee, Seok-Ho;Choe, Eun-Cheol;Gang, Mun-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.2
    • /
    • pp.79-86
    • /
    • 2002
  • Nowadays there is a trend to apply the diffusion equation to image Processing. The anisotropic diffusion equation is highly favoured as a noise removal algorithm because it can remove noise while enhancing edges. However if the two dimensional anisotropic diffusion equation is applied to the noise removal of video sequences, flickering artifact due to the luminance difference between frames and ghost artifact due to the interfiltering between frames occur. In this paper the two dimensional anisotropic diffusion equation is extended to the sequence axis. The Proposed three dimensional anisotropic diffusion equation removes noise more efficiently than the two dimensional equation, and furthermore removes the flickering and ghost artifact as well.

Removal Method of Signal Interference between Ultrasound Sensors (초음파 센서 간 신호 간섭 제거 방법)

  • Im, Hyungchul;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.584-590
    • /
    • 2021
  • This paper proposes a removal method of signal interference between ultrasound sensors where ghost signals due to interference are excluded and correct signal is recognized in distance mensurement using ultrasound sensors. The proposed method detects and excludes ghost signals when previous measured distance is compared to current measured distance and the distance difference exceeds a threshold. The threshold is fixed in conventional methods, so ghost signals cannot be correctly excluded when ultrasound sensor or target object move rapidly. On the contrary, to improve accuracy, the threshold is not fixed in the proposed method, and the threshold is adpatively determined based on the relative velocity when ultrasound sensor or target object move. Experiments of distance measurement with ultrasound signal interference are carried out where multiple ultrasound sensors of same type are exploited with maximum interference, and the results show that the proposed method efficiently exclude ghost signals.

Solid Reconstruction from a Set of the Orthogonal Three Views (삼면도로부터 솔리드의 자동생성에 관한 연구)

  • 박시형;이성수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.683-686
    • /
    • 1995
  • The automatic solid reconstruction is one of the important problems in CAD. Nowadays solid reconstruction has been done many areas, we will proposed this algorithm contribute to that development. this paper presents the algorithm to automatically reconstruct the soild form a set of the orthogonalal three views.

  • PDF

Hole-Filling Method Using Extrapolated Spatio-temporal Background Information (추정된 시공간 배경 정보를 이용한 홀채움 방식)

  • Kim, Beomsu;Nguyen, Tien Dat;Hong, Min-Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.8
    • /
    • pp.67-80
    • /
    • 2017
  • This paper presents a hole-filling method using extrapolated spatio-temporal background information to obtain a synthesized view. A new temporal background model using non-overlapped patch based background codebook is introduced to extrapolate temporal background information In addition, a depth-map driven spatial local background estimation is addressed to define spatial background constraints that represent the lower and upper bounds of a background candidate. Background holes are filled by comparing the similarities between the temporal background information and the spatial background constraints. Additionally, a depth map-based ghost removal filter is described to solve the problem of the non-fit between a color image and the corresponding depth map of a virtual view after 3-D warping. Finally, an inpainting is applied to fill in the remaining holes with the priority function that includes a new depth term. The experimental results demonstrated that the proposed method led to results that promised subjective and objective improvement over the state-of-the-art methods.

Broadband Seismic Exploration Technologies via Ghost Removal (도깨비파 제거를 통한 광대역 탄성파 탐사 기술)

  • Choi, Woochang;Pyun, Sukjoon
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.3
    • /
    • pp.183-197
    • /
    • 2018
  • In the delineation of geological structures using seismic exploration, it is very important to improve resolution of seismic data as well as accurate velocity model building and subsurface imaging. The resolution of seismic data can be enhanced by employing high-frequency energy sources or by applying deconvolution techniques in data processing. In marine seismic exploration, however, the main reason for degradation of resolution is the loss of specific frequency components due to ghosts. If we remove the ghosts, we can obtain broadband seismic data by avoiding frequency loss, and thus providing high-resolution subsurface images. Although ghosts can be properly filtered out in the data processing step, more effective broadband seismic technologies have been developing through the evolution of seismic instruments and the innovation of survey design. Overseas exploration companies developed brand-new configurations of receivers such as over/under streamer and variable-depth streamer, or ghost removal techniques using dual-sensor streamer to serve high-resolution imaging technologies. Unfortunately, neither broadband seismic instrument nor processing technique has been studied in Korea. In this paper, we introduce fundamental theories and current status of broadband seismic technologies to assist domestic researchers to study those technologies.

CALCIFYING ODONTOGENIC CYST ASSOCIATED WITH UNERUPTED TOOTH : REPORT OF A CASE (미맹출치를 동반한 Calcifying Odontogenic Cyst)

  • Ryu, Sun-Youl;Chung, Jung-Jae;Chung, Jong-Chull;Park, Jun-Ah;Choi, Hong-Ran
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.2
    • /
    • pp.105-112
    • /
    • 1993
  • A case of calcifying odontogenic cyst associated with an unerupted tooth which appeared in the left maxillary sinus of a 16-year-old woman, was reported. Clinical examination revealed painless swelling on the left maxillary posterior region and the cheek. Radiographically, this lesion showed a monolocular radiolucent shadow with calcified materials and unerupted maxillary second premolar. Histological examination revealed cystic structure with presence of the ghost cells, calcified tissue and unerupted tooth. This lesion was classified as Type IB of COC according to classification of the Praetorius. After surgical removal of the cyst, the wound healed uneventfully and the lesion is now free of symptoms.

  • PDF

Numerical Study of Droplet Motion in a Microchannel with defferent contact angles (접촉각에 따른 마이크로채널 내에서의 액적 거동에 대한 수치적 연구)

  • Choi, Ji-Young;Son, Gi-Hun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.656-657
    • /
    • 2008
  • The droplet dynamics in a hydrophilic/hydrophobic microchannel, which is applicable to a typical proton exchange membrane fuel cell (PEMFC), is studied numerically by solving the equations governing conservation of mass and momentum. The liquid-gas interface or droplet shape is determined by a level set method which is modified to treat contact angles. The matching conditions at the interface are accurately imposed by incorporating the ghost fluid approach based on a sharp-interface representation. The effects of contact angle, inlet flow velocity, droplet size and side wall on the droplet motion are investigated parametrically. Based on the numerical results, the droplet dynamics including the sliding and detachment of droplets is found to depend significantly on the contact angle. Also, a droplet removal process is demonstrated on the combination of hydrophilic and hydrophobic surfaces.

  • PDF

Range Design of Pulse Repetition Frequency for Removal of SAR Residual Image (영상레이더 잔상 제거를 위한 펄스 반복 주파수의 범위 설계)

  • Kim, Kyeong-Rok;Heo, Min-Wook;Kim, Tu-Hwan;Ryu, Sang-Burm;Lee, Sang-Gyu;Lee, Hyeon-Cheol;Kim, Jae-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1653-1660
    • /
    • 2016
  • The synthetic aperture rardar (SAR) is an active sensor using microwaves. It transmits a microwave signal, called a chirp pulse, and receives the reflected signal in a moving platform such as satellite and unmanned aerial vehicle. Since this sensor uses microwaves that can penetrate the atmosphere, SAR generates the images regardless of light and weather conditions. However SAR operates on the moving platform, the Doppler shift and the side-looking observation method should be considered. In addtion, a residual image or ghost image can be occurred according to selection of the pulse repetition frequency (PRF). In this paper, a range design of the PRF for the L-band spaceborne SAR system is studied for prevention of SAR image distortion. And the system is studied for prevention of SAR image distortion. And the system parameter and the PRF are calibrated iteratively according to the proposed system design procedure and design constraints. The MATLAB based on SAR system simulator has been developed to verify the validity of calculated PRF. The developed simulator assumes that SAR sensor is operated by the PRF calculated from the design. The results of the simulator show that the targets in image has a valid peak to side-lobe ratio (PSLR) so that the PRF can be used for the spaceborne SAR sensor.

Na, K-ATPase Activity in the Aged Erythrocytes of Hypertensive Rats (고혈압쥐 노화 적혈구에서의 Na, K-ATPase에 관한 연구)

  • Park, Chang-Kil;Hur, Gang-Min;Seok, Jung-Ho;Lee, Jae-Heun
    • The Korean Journal of Pharmacology
    • /
    • v.27 no.1
    • /
    • pp.33-43
    • /
    • 1991
  • To study the age dependent change of Na, K-ATPase in the erythrocyte of hypertensive rat, 1-kidey 1-clip hypertensive rat was made by the removal of right kidney and partial ligation of left renal artery. After 4 weeks, aged erythrocyte fraction was separated by density gradient centrifugation, and Na, K-ATPase activity and $^3H-ouabain$ binding with ghost cell membrane and ouabain sensitive Rb-uptake with whole cell were measured. 1) In the hypertensive rats, blood pressure was significantly increased to 165.5/119.0 mmHg (systolic/diastolic). Mean corpuscular volume and membrane protein(mg) per $10^9RBC$ were decreased and hemoglobin content was increased in the aged erythrocyte. 2) Na, K-ATPase activity in the solution containing 110 mM NaCl and 10 mM KCI, was decreased in hypertensive rat, and decreased in aged erythrocyte of both group. 3) Ouabain sensitive Rb-uptake by low RbCl concentration(4 mM) was slightly decreased in aged erythrocyte compared to that in young erythrocyte of each group, but slightly increased in young erythrocyte in hypertensive rat compared to that in normotensive rat. 4) Ouabain sensitive Rb-uptake by high RbCl concentration(16 mM) was decreased about 30% to 50 % in aged erythrocyte in both group. And in hypertensive rat, especially in young erythrocyte it was significantly decreased compared to that in normotensive rats. 5) $^3H-ouabain$ binding at 0.13 or $1{\times}10^-6M$ ouabain concentration was slightly decreased in aged erythrocyte of normotensive rat, and significantly decreased in aged erythrocyte of hypertensive rats. 6) $^3H-ouabain$ binding at 6 or $64{\times}10^-6M$ ouabain concentration is slightly decreased in aged erythrocyte of both group, but significantly decreased in young and aged erythrocyte of hypertensive rats compared to that of normotensive rats. The present results suggest that (1) in the young erythrocyte of hypertensive rat, the alterations of Na-pump activity that slightly increased in weak stimulation and inhibited in strong stimulation, may be related to increased molecular activity and the decrease in the number of low affinity site without change in high affinity site, (2) in the aged erythrocyte of normotensive rat, inhibited Na-pump may be related to the change in molecular activity of pump. (3) And in the aged erythrocyte of hypertensive rat, it may be related to the decrease in the number of high and low affinity site as well as the change in molecular activity

  • PDF