• Title/Summary/Keyword: Ghost cell

Search Result 64, Processing Time 0.025 seconds

Fine Needle Aspiration Cytology of Pilomatrixoma - Two Cases Report - (모기질세포종의 세침흡인 세포학적 소견 - 2예 보고 -)

  • Paik, Seung-Sam;Kim, Dong-Hoon;Lee, How-Jin;Jang, Se-Jin;Park, Moon-Hyang;Lee, Jung-Dal
    • The Korean Journal of Cytopathology
    • /
    • v.8 no.2
    • /
    • pp.155-159
    • /
    • 1997
  • Pilomatrixoma is a benign skin appendage tumor of hair matrix cell origin. The cytological appearance of this tumor may cause problems when attempting to establish a differential diagnosis with other neoplasms. Herein we report the aspiration cytology findings of two cases of pilomatrixoma. One case was diagnosed as atypical cell clusters initially and the other was diagnosed as pilomatrixoma. On cytologic examination, both cases showed clusters of tightly arranged basaloid cells with an uniform appearance, scanty cytoplasm and round hyperchromatic nuclei. There were histiocytes and multinucleated foreign body giant cells merged with the amorphous opaque orangeophilic materials of "ghost cells". The differential diagnosis with other neoplasms is discussed.

  • PDF

A Study on Performance of Protective Gloves to Isocyanate Toxicity (이소시안화물 독성에 대한 보호장갑의 성능 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.62-69
    • /
    • 2008
  • As the concerns of dermal exposure of spray painters to isocyanates in the automobile industry, glove performance was examined like permeation rate and breakthrough time including fatigue test. Methylene chloride was used as the solvent for derivatization of the isocyanates with a 97.5% recovery. Ghost wipe pads were used to wipe the surface of the glove material after chemical penetration through the glove material placed under a disposable test cell. Several solvents were tested, such as thinner(xylene, toluene) and cleaning agent(acetone) by using a standard permeation test cell(AS/NZS standard 2161. part 10.3). Solvents accelerate chemical permeation through the gloves more quickly than pure HDI hardener products. The longest breakthrough times were from Nitrosolve gloves, not detected in 8 hours, compared with others like Latex, Neoprene, TNT and Dermo Plus. Therefore Nitrosolve gloves could be recommended as personal protective equipment in crash repair shops. In addition, revised exposure limit of korean regulation should be suggested for employee to minimize the risk of health symptoms.

CALCIFYING ODONTOGENIC CYST ASSOCIATED WITH ODONTOMA : CASE REPORT (치아종을 동반한 석회화 치성낭에 관한 증례 보고)

  • Lee, Seon-Suk;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.109-115
    • /
    • 2006
  • The calcifying odontogenic cyst (COC) predominantly affected Maxillary anterior segment and it is developmental cyst. But COC showed diverse terminology or classification, clinicopathologic features as well as its biologic behavior COC usually presents as slowly enlarging but otherwise symptomless swelling. Association with impacted teeth and odontoma is described in $24{\sim}30%$. The epithelial lining of COC(ghost cell) appears to have ability to induce the formation of dental tissues in the asjcents connective tissue wall. This case is a COC associated with a odontoma involving an impacted left maxillary canine in 14-year-old female child. Radiographic examination revealed a well-demarcated radiolucent lesion partially occupied by a radiopaque mass, involving the left canine. The histologic sections showed cystic cavity lined with ameloblastic epithelium containing ghost cell masses with regular and irregular shape odontoma. The final pathologic diagnosis was calcifying odontogenic cyst with odontoma(Type IB by Preatorius). Enucleation and elimination of the included tooth were performed. Now endodontic treatment was preformed on the 1st premolar of the upper left jaw, which had a lesion. And the patient and their parents want to have the orthodontic treatment performed and would like to keep the space maintainer.

  • PDF

A Design of Ferrite Electromagnetic Wave Absorber for Anechoic Chamber (전파무향실용 페라이트 전파흡수체의 설계)

  • 이창우;김동일;김하근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.11a
    • /
    • pp.408-413
    • /
    • 1998
  • Electromagnetic wave absorbers for anechoic chamber are needed to broaden the useful frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve it the alone requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer(practically use urethane foam, etc.) on the ferrite tile. Therefore, an air layer is formed between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 600 MHz in bandwidth. Accordingly, in this paper, a broadened electromagnetic wave absorber will be designed, which has the reflection characteristics less than -20 dB from 30 MHz to 6000 MHz in the bandwidth. Then we will design a super broadband electromagnetic wave absorber by inserting square Ferrite Cylinders Type with the thickness less than 11 m and with the frequency band from 30 MHz to 6000 MHz under the above tolerance limits. The purpose of this research is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for prevention TV ghost, etc.

  • PDF

Two cases report of Calcifying Odontogenic Cyst (석회화치성낭의 두 증례보고)

  • Lee, Byung-Do;Lee, Wan;Paeng, Jun-Young;Lee, Jun;Choi, Moon-Ki;Son, Hyun-Jin
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.169-173
    • /
    • 2009
  • The calcifying odontogenic cyst (COC) is a rare disorder of the jaws and shows various radiographic features. The purpose of this study is to describe the different radiographic appearances of 2 cases of COC. Case 1 was located in the posterior maxilla extending into maxillary sinus, showing unilocular radiolucency with a well-defined margin. Cortical bone expansion and thinning were prominent. Root resorption of adjacent teeth was apparent. Case 2 showed unilocular radiolucency with a calcified material. Calcification was supposed to be dystrophic dental hard structures, detected at the periphery of the lesion. Ghost cell and proliferation of ameloblastoma-like tissues were common features for these two lesions on histopathological findings. This reports presented common and atypical radiographic features of the COC.

  • PDF

A Design of Ferrite Electromagnetic Wave Absorber Three Layered Type with Wide-Band Characteristics. (광대역 특성을 갖는 3층형 페라이트 전파흡수체의 설계)

  • 이창우;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.4
    • /
    • pp.51-57
    • /
    • 1998
  • According to the rapid development of the electric industry, the demand of the frequency allocation and the usage of electromagnetic wave are increased due to automation of modem society. Electromagnetic wave absorbers for anechoic chamber are needed to broaden the effective frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve the above requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the effective frequency bandwidth by the way of forming air layer(practically in urethane foam, etc.) on the ferrite tile. Therefore, an air layer is formed between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 400 MHz in bandwidth. In this paper, a broadband electromagnetic wave absorber are designed, which has the reflection characteristics less than -20 dB from 30 MHz to 8,000 MHz in the bandwidth. A super broadband electromagnetic wave absorber is achieved by inserting square Ferrite Cylinders Type with the thickness less than 23.5 mm and with the frequency band from 30 MHz to 8,000 MHz under the above tolerance limits. The purpose of this research is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell and also a wall material for preventing TV ghost, etc.

  • PDF

Design of Ferrite Electromagnetic Wave Absorber for Anechoic Chamber (전파무향실용 페라이트 전파흡수체의 설계)

  • 김동일;이창우;김하근;전상엽;정세모
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • Electromagnetic wave absorbers for anechoic chamber are needed to broaden the useful frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve the above requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer. Therefore, an air layer is formed absorber between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 450 MHz in frequency band, far narrower than the aimed bandwidth. The purpose of this paper is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for prevention of TV ghost, etc. Accordingly, in this paper, a broadened electromagnetic wave absorber is designed, which has the reflection characteristics less than -20 dB from 30 MHz to 5,430 or 8,000 MHz in the bandwidth. Then we will design a super broadband electromagnetic wave absorber by inserting square Ferrite Cylinders Type with the thickness less than 23.5 m in three-layed type and with the frequency band from 30 MHz to 5,430-8,000 MHz under the above tolerance limits.

  • PDF

USEFULNESS OF $^{18}F$-FDG PET/CT IN THE EVALUATION OF CERVICAL LYMPH NODE METASTASIS IN PATIENTS WITH ORAL CANCER (구강암 환자에서 $^{18}F$ FDG-PET/CT의 경부 림프절 전이 평가 유용성)

  • Yu, Min-Gi;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.213-220
    • /
    • 2009
  • Purpose: The present study was aimed to examine the usefulness of 18F-FDG PET/CT in the evaluation of cervical lymph node metastasis in patients with oral cancer. Materials and methods: Twenty-two patients who underwent neck dissection to treat oral cancer were subjected for examination. The cervical node metastasis was evaluated by means of clinical examination, CT scan, PET, and histologic examination. By comparing the results of each examination modality with those of histologic examination, it's sensitivity, specificity, positive predictive value, and negative predictive value were determined. Results: The oral cancer was more frequent in males with a ratio of 2.14:1. The sixth decade showed the highest incidence in age distribution with mean of $56{\pm}16$. Histologic findings showed that squamous cell carcinoma was the most common (15 patients), and mucoepidermoid carcinoma (3), malignant melanoma (2), and adenoid cystic carcinoma and ghost cell odontogenic carcinoma (1 each), in order. In most cases, wide surgical excision of the primary cancer and neck dissection was performed, followed by reconstruction with free flaps when necessary. When comparing the results of each examination modality with those of the histologic examination, clinical examination showed sensitivity, specificity, positive predictive value, and negative predictive value at 11%, 85%, 33%, and 58%, respectively. CT scans showed at 67%, 77%, 67%, and 77%, while $^{18}F$-FDG PET/CT at 78%, 77%, 70%, and 83%, respectively. Conclusions: These results suggest that PET is more useful, compared with clinical examination and CT scans, in the evaluation of cervical lymph node metastasis in patients with oral cancer.

Tumor-Suppressing Effects of Saponin-SOD in Nude Mice (Saponin-SOD가 SNUC-4 Cell에 의해 유발편 대장암 Nude Mice의 암 성장 억제 효과)

  • 박수진;강명화
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.14 no.4
    • /
    • pp.338-342
    • /
    • 2004
  • This study was performed to measure the antioxidant effects of red ginseng extracts which antioxidation had been promoted through enzyme hydrolysis. In order to observe their tumor-suppressing effects, an anti-cancer medicine and Saponin-SOD, which was a highly antioxidant beverage made from red ginseng saponin adding SOD-like rice (with embryo buds) extracts, were administered to nude mice with large intestine cancer induced. There was a significant increase in the content of phenolic compounds as the enzyme was added. The red ginseng extracts showed a high electron-donating ability with the passage of time. The electron-donating ability was particularly high in the enzyme-treated red ginseng extract, and also observed as high in Saponin-SOD. The lipid-peroxide generation was inhibited depending on the concentration of Saponin-SOD added; the addition of 0.625% Saponin-SOD served to decrease the inhibition level up to 65% compared with the case of no addition (100%). As a result, it could be assumed that Saponin-SOD would strongly inhibit the oxidation of ghost membrane. After the cancer was induced in nude mice through the injection of SNUC-4 cell, there was a significant inhibition in the growth of tumors in nude mice into which Saponin-SOD were injected; the growth of tumors was gradually decreasing with the passage of time after the cancer induction. In particular, when Saponin-SOD was administered together with an anti-cancer medicine, the synergic effect was observed. In conclusion, Saponin-SOD, when used with an anti-cancer medicine, is expected to reduce the amount of free radical and lipid peroxide, which are known to cause harmful effects occurring from the internal application of medicine.

  • PDF

A Study on Broad-Band Design of Electromagnetic Wave Absorber in Ferrite Cylinder Insertion Type (페라이트 기둥 삽입형 전파흡수체의 광대역 설계에 관한 연구)

  • 이창우;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 1999
  • With a rapid progress in electronic industry we enjoy various conveniences of life. As many kinds of information equipments are supplied even to most of individuals as to be called an information society, we are exchanging much information with one another surprisingly. Consequently the occupation density of microwave frequency band is highly increased, and electromagnetic environment is getting more seriously bad. It often gives fatal blow to even human life and thus becomes serious social problems. Electromagnetic wave absorbers for anechoic chamber are needed to broaden the effective frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve it the alone requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer(practically use urethane foam, etc.) on the ferrite tile. Therefore, an air layer is formed between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 400 MHz in bandwidth. Accordingly, in this paper, a broadened electromagnetic wave absorber are designed, which has the reflection characteristics less than -20 dB from 30 MHz to 6,000 MHz in the bandwidth. Then we achieved the goal by design the inserting square Ferrite Cylinders with the thickness less than 17.5 mm on existing grid type Ferrite absorber. The purpose of this research is on the development of very wide-band electromagnetic absorber for a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for preventing TV ghost, etc.

  • PDF