• 제목/요약/키워드: Geothermal heat exchange system

검색결과 53건 처리시간 0.026초

수치 시뮬레이션을 이용한 수직밀폐형 지열시스템의 채열특성에 관한 연구 (Study on the characteristic of heat exchange for vertical geothermal system using the numerical simulation)

  • 남유진;오진환
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.66-72
    • /
    • 2014
  • Ground source heat pump system can achieve high efficiency of performance by utilizing annually constant underground temperature to provide heat source for space heating and cooling. Generally, the depth of constant-temperature zone under the ground depends on surface heat flux and soil properties. The deeper the ground heat exchanger is installed, the higher the heat exchange rate can be acquired. However, in order to optimally design the system, it is necessary to consider both the installation cost and the system performance. In this study, performance analysis of ground source heat pump system according to the depth has been conducted through the case study.

열교환기의 흐름개선을 통한 고효율 지열 히트펌프 시스템에 관한 연구 (A Study on High Efficiency Geothermal Heat Pump System by Improving Flow of Heat Exchanger)

  • 안성환;최재상;김상범;안형환
    • 한국가스학회지
    • /
    • 제21권4호
    • /
    • pp.42-46
    • /
    • 2017
  • 화석연료의 무분별한 사용으로 인한 이산화탄소의 대기 중 방출은 지구의 연평균 기온을 상승시키는 원인으로 작용하고 있다. 이를 해결하기 위한 대체에너지로써 지열은 연중 일정한 온도를 갖는 무한자원이다. 지열에너지를 널리 보급하기 위해서는 히트펌프의 성능과 지중열교환기의 열교환 효율이 매우 중요하다. 이에 본 연구는 히트펌프의 성능을 증가시키기 위해 팽창변을 이중으로 구성하고 지중열교환기의 열교환 효율을 높이기 위해 입출관과 유입관 사이에 간격유지부재를 사용하여 실험하였다. 실험한 결과 팽창변을 이중으로 구성하였을 때 냉난방 능력이 최대 11.4%가 증가됨을 얻을 수 있었고, 간격유지부재를 사용 시 열교환 효율이 17.5% 향상되었다. 이러한 결과를 토대로 지열시스템의 설치 시 히트펌프의 성능과 지중열교환기의 열교환 효율의 상승으로 인해 설치비용이 많이 절감될 것으로 판단된다.

현장타설말뚝형 에너지 파일의 시공형태별 지중 열교환량에 관한 연구 (The Effect of Construction Methods on Geothermal Exchange Rates of Cast-in-place Energy Piles)

  • 박용부;남유진;심영종;손정락
    • 토지주택연구
    • /
    • 제3권2호
    • /
    • pp.169-175
    • /
    • 2012
  • 최근, 지열 냉난방 시스템의 초기 공사비를 절감하기 위해 연구되고 있는 에너지 파일의 열교환량을 산정하기 위해 2종류(부속연결형, 슬링키형)의 현장타설말뚝형(PRD, 시공심도 4.5m, 직경 1,200mm) 에너지 파일을 시험시공하고 수치 시뮬레이션에 의해 효율을 상호 비교하였다. 상호 비교결과에 의하면 지중 교환량은 운전시작과 함께 채열에 의한 지중온도의 저하에 의해 점점 감소하였고 부속연결형의 평균 열원수의 온도차는 난방운전에서 $0.37^{\circ}C$, 냉방운전에서 $0.34^{\circ}C$로 나타났다. 또, 부속연결형의 난방운전시 열교환량 231.4W/m보다 냉방운전의 방열량은 252.2W/m로서 9% 높았고 슬링키형은 난방 기간 평균 열교환량이 168.0W/m로 부속연결형에 비해 약 27% 낮은 열교환량을 얻었다.

지중온도회복을 고려한 지열 히트펌프 시스템의 운전방법 검토 (Study on the Operation Method of Ground Source Heat Pump System Considering Recovery of Ground Temperature)

  • 배상무;전재영;권영식;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.24-30
    • /
    • 2020
  • Ground source heat pump (GSHP) systems are actively introduced as cooling and heating conditioning systems of buildings due to annual stable performance and easily maintenance. However, ground temperature imbalance is occurred when the GSHP is used for a long period. Therefore, in this study, we proposed the operation method of the system that considered the recovery time of heat source temperature. The entering water temperature (EWT) and heat exchange rate (HER) were comparatively analyzed according to the continuous and intermittent operation. Furthermore, the underground thermal environment was evaluated by numerical analysis model. As the result, the intermittent operation was a maximum of 12.3% higher HER during the heating period than the continuous operation. In addition, the overall ground heat source temperature at the intermittent operation was higher than it at the continuous operation.

열교환방식에 따른 지열히트펌프의 난방특성에 관한 연구 (A Study on Heating Characteristics of Ground Source Heat Pump with Variation of Heat Exchange Methods)

  • 차동안;권오경;박차식
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2012
  • The objective of this study is to investigate the influence on the heating performance for a water-to-water 10RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The heating capacity and COP of the heat pump increased with increasing ground heat source temperature. As a result, compared to a refrigerant switching method, the water switching method with counter flow improves the heating capacity and COP by approximately 5% in average, respectively.

지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구 (A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;박경순
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

열응답 실험 해석 및 국내 현황 (Thermal Response Test (TRT) interpretation and the status in Korea)

  • 심병완;최충현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.168.2-168.2
    • /
    • 2010
  • The growing market for geothermal heat pump system requires great consideration of quality control and assurance in design and construction. The borehole heat exchanger of GHP system should be sustainable, economical and ecological. Thermal Response Test (TRT) is a useful method for site investigation to obtain reliable data for a optimal system design from the technical and economical aspect. Intensive researches combined with exchange of experiences on an international level within the IEA ECES Annex 21 improved the technology. Major subjects on the interpretation of TRT are development of improved evaluation models, evaluation of the TRT with respect to geological layers and investigation of the influence of ground water. Current status of TRT in South Korea, as well as a new version of the Korean TRT standard test procedure was presented. TRT is mostly used for governmental supported projects with corresponds to more than 100 GCHP systems per year. More than 200 tests are applied, mostly on single U-tube heat exchangers (about 95%). Bentonite is the most common grouting to be used. KIGAM (Korea Institute of Geoscience & Mineral Resources) is also keeping a GIS geological and geothermal database. In the institute also laboratory measurements of rock properties are carried out. About 90% of the laboratory measurements of the rock heat conductivity shows higher values than the in-situ TRT.

  • PDF

출구 온도를 고려한 수평형 지중열교환기의 매설 지침에 관한 연구 (A Study on Burial Guideline of Horizontal Geothermal Heat Exchanger based on Exit Temperature)

  • 조성우;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.553-558
    • /
    • 2014
  • Geothermal energy can be used with a geothermal heat pump or an earth-to-air heat exchange system (EAHES), which is referred to as a "cooling tube" in Korea. In this study, we suggest EAHES burial guidelines in terms of the parameters of buried pipe length and air velocity regarding the exit air temperature of EAHES. The exit air temperature for EAHES in three regions (Changwon, Busan and Seoul) was calculated with variation in buried pipe length and air velocity at ${\Phi}100mm$ and ${\Phi}200mm$. In conclusion, variation in the buried pipe length is more effective than that of air velocity to achieve the required exit air temperature.

태양열 및 지열 이용 히트펌프 시스템의 성능예측 시뮬레이션에 관한 연구 (Study on the Performance Prediction Simulation of the Heat Pump System using Solar and Geothermal Heat Source)

  • 남유진;까오신양
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.75-81
    • /
    • 2014
  • Recently, the use of renewable energy has been attracted due to the interest in energy-saving and the reduction of CO2 emission. In order to reduce the energy consumption of the cooling and the heating in the field of the architectural engineering, heat pump systems using renewable energy have been developed and used in various applications. In many researches, integrated heat pump systems are suggested which use solar and geothermal heat as the heat source for cooling and heating. However, it is still difficult to predict the performance of the systems, because the characteristic of heat exchange in each system is complicated and various. In this system, the performance prediction simulation of the heat pump was developed using a dynamic simulation model. This paper describes the summary of the suggested systems and the result of the simulation. The average temperature of the heat source, heating loads and COP were calculated with the cases of different local conditions, different system composition and different operation time by TRNSYS 17.

지열-열펌프 시스템의 온실냉방 및 육묘 효과 (Effect of Greenhouse Cooling and Transplant Quality Using Geothermal Heat Pump System)

  • 이재한;이용범;권준국;강남준;김학주;최영하;박진면;이한철
    • 생물환경조절학회지
    • /
    • 제15권3호
    • /
    • pp.211-216
    • /
    • 2006
  • 지열을 이용한 열펌프 시스템이 온실의 냉방과 과채류의 묘소질에 미치는 영향을 구명하였다. 온실 내 기온은 주간에는 차광구에 비해서 포그+차광구가 $3{\sim}4^{\circ}C$ 낮았고, 야간에는 지열-펌프+차광구가 차광 및 포그+차광구에 비해 $5{\sim}7^{\circ}C$ 낮았다. 오이, 고추 및 토마토 묘의 초장은 차광이나 차광+포그구에 비해 지열-열펌프+차광구가 가장 짧았고, 엽면적과 건물중은 지열-열펌프+차광구가 다른 처리에 비해 약간 작았다. 결과적으로 건묘지수는 지열을 이용하여 냉방을 한 지열+차광구는 포그+차광구 및 차광구에 비해 모두 높게 나타났다.