• Title/Summary/Keyword: Generator set

Search Result 388, Processing Time 0.022 seconds

A Study for Development the Air Cleaner Using Air Ionizing Phenomena and Optical Catalizer (공기전리 현상과 광촉매를 이용한 공기정화 장치 개발에 관한 연구)

  • Shim, Chung-Han;Lee, Won-Dae;Lee, Dong-Hoon;Jung, Yong-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.28-33
    • /
    • 2006
  • The rapidly advanced industrial society takes advantage of high-technology, but it also suffered from the side effects such as various diseases by contamination. Of these problems, air pollution is considered as the most important problem nowadays. Air contamination is not only limited outdoors, but it also causes more serious effect in our indoor air environment. Depending on the notion that indoor air effects physical health seriously, the needs of the air cleaner is more earnest. Therefore, the main purpose of this study is to develop the air cleaner to meet the standard and get rid of poisonous and harmful material from the atmosphere by using a Corona Discharge. According to the purpose of this study, We set the negative ion generator, the UV, $TiO_{2}$ optical catalyzer, the electrical dust collector and the air filter in series order. It emits a lot of negative ions. We use these ions to purify harmful factors and contaminated materials. We collect the dust using static power that comes from the discharge of corona. At the same time, we try to develop the air cleaner to keep the air quality to meet the standard and kill the various viruses using UV LED and $TiO_{2}$ optical catalyzer. In this study, we use the UV LED that is smaller and efficient than a existing UV lamp. What is more, the UV LED has a features that a stabilizer occupying much space is not needed any more.

A design of Hybrid power generation system for Ocean facilities (해양시설물용 하이브리드 발전시스템 설계)

  • Jung, Sung-Young;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.33 no.6
    • /
    • pp.381-385
    • /
    • 2009
  • Generally power system of ocean facility composes a solar generation system.The power to be generated by the solar system is changed according to the amount of sunlight of weather conditions. Output power of solar system is decreased with weather condition such as cloudy day and rainy day. And the power shortage of the ocean facility can occur due to the lack of solar energy. To solve this problem, this paper proposes the power control system for solar-wave hybrid system Wave generation system consists of wells turbine and permanent magnet synchronous generator(PMSG). This propose system set the specific area and measures the solar generation power and wave generation power. As a result of experiment, the solar power is a more static source than wave power, but the wave power provides energy during periods of no sunshine. The power characteristic of propose hybrid system have been obtained high reliability than a solar generation system.

A Study on the Feasibility of IGCC under the Korean Electricity Market (국내 전력거래제도하에서 IGCC 사업성 확보를 위한 정책 제언)

  • Ko, Kyung-Ho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.1
    • /
    • pp.118-127
    • /
    • 2011
  • An IGCC was evaluated as one of the next generation technologies that would be able to substitute for coal-fired power plants. According to "The 4th Basic Plan of Long-term Electricity Supply & Demand" which is developed by the Electricity Business Acts, the first IGCC will be operated at 2015. Like other new and renewable energy such as solar PV, Fuel cell, The IGCC is considered as non-competitive generation technology because it is not maturity technology. Before the commercial operation of an IGCC in our electricity market, its economic feasibility under the Korean electricity market, which is cost-based trading system, is studied to find out institutional support system. The results of feasibility summarized that under the current electricity trading system, if the IGCC is considered like a conventional plant such as nuclear or coal-fired power plants, it will not be expected that its investment will be recouped within life-time. The reason is that the availability of an IGCC will plummet since 2016 when several nuclear and coal-fired power plants will be constructed additionally. To ensure the reasonable return on investment (NPV>0 IRR>Discount rate), the availability of IGCC should be higher than 77%. To do so, the current electricity trading system is amended that the IGCC generator must be considered as renewable generators to set up Price Setting Schedule and it should be considered as pick load generators, not Genco's coal fired-generators, in the Settlement Payment.

Development of RF Ion Source for Neutral Beam Injector in Fusion Devices

  • Jang, Du-Hui;Park, Min;Kim, Seon-Ho;Jeong, Seung-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.550-551
    • /
    • 2013
  • Large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER plasmas. Negative hydrogen (deuterium) ion sources are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF ion sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck- Institute for Plasma Physics, Garching) for ASDEX-U and W7-AS neutral beam injection (NBI) systems. In recent, the first NBI system (NBI-1) has been developed successfully for the KSTAR. The first and second long-pulse ion sources (LPIS-1 and LPIS-2) of NBI-1 system consist of a magnetic bucket plasma generator with multi-pole cusp fields, filament heating structure, and a set of tetrode accelerators with circular apertures. There is a development plan of large-area RF ion source at KAERI to extract the positive ions, which can be used for the second NBI (NBI-2) system of KSTAR, and to extract the negative ions for future fusion devices such as ITER and K-DEMO. The large-area RF ion source consists of a driver region, including a helical antenna (6-turn copper tube with an outer diameter of 6 mm) and a discharge chamber (ceramic and/or quartz tubes with an inner diameter of 200 mm, a height of 150 mm, and a thickness of 8 mm), and an expansion region (magnetic bucket of prototype LPIS in the KAERI). RF power can be transferred up to 10 kW with a fixed frequency of 2 MHz through a matching circuit (auto- and manual-matching apparatus). Argon gas is commonly injected to the initial ignition of RF plasma discharge, and then hydrogen gas instead of argon gas is finally injected for the RF plasma sustainment. The uniformities of plasma density and electron temperature at the lowest area of expansion region (a distance of 300 mm from the driver region) are measured by using two electrostatic probes in the directions of short- and long-dimension of expansion region.

  • PDF

Effects of Additives and Ignition Support Material on HTPB Fuel Grains for Solid Fuel Ramjet (고체연료 램젯용 HTPB 연료그레인에 첨가제와 점화보조제가 미치는 영향)

  • Jung, Woosuk;Baek, Seungkwan;Jung, YeonSoo;Kwon, Taesoo;Park, Juhyun;Kim, Incheol;Kwon, Sejin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.957-967
    • /
    • 2017
  • Firing test of the fuel grain for solid fuel ramjet with additives and ignition support material was conducted. Fuel grain consist of HTPB mixed with AP particle 15 wt.%, Boron particle 5 wt.%. To cause the short ignition delay, ignition support consist of $NC/BKNO_3$ and composite propellant was coated to the fuel grain. An oxidant gas having a controlled temperature, pressure and oxygen composition close to the air condition in the ramjet combustor was supplied using the Ethanol blended $H_2O_2$ gas generator. Gas was set to flow at a mass flow rate of 150 g/s and mass flux of $200kg/m^2s$ in the grain port. Through the test, ignition support operated well and ignition delay of 0.5. During the test, stable chamber pressure with 8 bar and high combustion efficiency of 0.86 was confirmed.

  • PDF

A Study on the Development of Oxygen Cluster Ion Generator for Sterilization of Bio Clean Room(BCR) (Bio Clean Room(BCR)의 멸균을 위한 산소 클러스터이온 발생 장치 개발에 관한 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • Bio Clean Room(BCR) and pharmaceutical product manufacturing facilities require careful assessment of many factors, including HVAC, controls, room finishes, process equipment, room operations, and utilities. Flow of equipment, personnel, and product must also be considered along with system flexibility, redundancy, and maintenance shutdown strategies. It is important to involve designers, operators, commissioning staff, quality control, maintenance, constructors, validation personnel, and the production representative during the conceptual stage of design. Critical variables for room environment and types of controls vary greatly with the clean space's intended purpose. It is particularly important to determine critical parameters with quality assurance to set limits and safety factors for temperature, humidity, room pressure, and other control requirements. In this paper, oxygen cluster ion equipment was utilized in order to enhance the indoor air quality and to prevent the airborne infection of ward in hospital. Moreover, the performance test of the equipment was also performed in order to develop the optimal sterilization system of BCR using the equipment.

An Enhancement of Learning Speed of the Error - Backpropagation Algorithm (오류 역전도 알고리즘의 학습속도 향상기법)

  • Shim, Bum-Sik;Jung, Eui-Yong;Yoon, Chung-Hwa;Kang, Kyung-Sik
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.7
    • /
    • pp.1759-1769
    • /
    • 1997
  • The Error BackPropagation (EBP) algorithm for multi-layered neural networks is widely used in various areas such as associative memory, speech recognition, pattern recognition and robotics, etc. Nevertheless, many researchers have continuously published papers about improvements over the original EBP algorithm. The main reason for this research activity is that EBP is exceeding slow when the number of neurons and the size of training set is large. In this study, we developed new learning speed acceleration methods using variable learning rate, variable momentum rate and variable slope for the sigmoid function. During the learning process, these parameters should be adjusted continuously according to the total error of network, and it has been shown that these methods significantly reduced learning time over the original EBP. In order to show the efficiency of the proposed methods, first we have used binary data which are made by random number generator and showed the vast improvements in terms of epoch. Also, we have applied our methods to the binary-valued Monk's data, 4, 5, 6, 7-bit parity checker and real-valued Iris data which are famous benchmark training sets for machine learning.

  • PDF

A Study on the Improvement of Voltage Measuring Method of 22.9 kV-y Distribution Lines (22.9 kV-y 배전선로의 전압계측방법 개선에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.293-299
    • /
    • 1998
  • An objective of this study is to develop a voltage measuring device that uses a gas-filled switch (GS) on 22.9 kV-y extra-high voltage distribution lines. The voltage measuring device proposed in this paper is a kind of capacitive divider which consists of a detecting electrode attached outside of the bushing of GS, an impedance matching circuit, and a voltage buffer. It can be easily installed in an established GS without changing the structure. For the calibration and application investigations, the voltage measuring device was set up in the 25.8 kV 400 A GS, and a step pulse generator having 5 ns rise time is used. As a result, it was found that the frequency bandwidth of the voltage measuring device ranges from 1.35 Hz to about 13 MHz. The error of voltage dividing ratio which is evaluated by the commercial frequency voltage of 60 Hz was less than 0.2%. In addition, voltage dividing ratio in the commercial frequency voltage and in a non-oscillating impulse voltage were compared, and their deviation were less than 0.7%.

  • PDF

Electromagnetic Retarder's Modeling and Voltage Control (전자기형 리타더의 모델링 및 전압제어)

  • Jung, sung-chul;Lee, ik-sun;Ko, jong-sun
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.171-173
    • /
    • 2016
  • 일반적으로 대형 버스 및 트럭 등 같은 경우, 부하가 아주 크다. 또한 내리막길이나 장거리 운행 시에 잦은 제동으로 인하여 마찰을 이용한 기존 방식의 브레이크들은 브레이크 파열 및 페이드 현상 때문에 제동 안전성에 문제가 있다. 이러한 제동 부담을 분담하기 위해 현재 보조브레이크(리타더)가 필수적이며, 엔진 계통의 보조브레이크가 아닌 비접촉식 브레이크 같은 친환경 보조브레이크가 요구되고 있다. 그리고 차량 제동시 발생하는 기계에너지를 전기에너지로 회생하여 에너지효율을 향상시키려는 연구가 현재 활발히 진행되고 있다. 본 논문에서는 와전류를 이용한 전자기형 리타더에서 발생되는 전기에너지를 회수하기 위한 전압 제어 방법을 다룰 것이다. 리타더의 제동에너지를 전기에너지로 회생하기 위해 L-C 공진회로로 구성하였다. 리타더를 자여자 유도발전기(Self-Excited Induction Generator)로 모델링 하였고 이를 토대로 시뮬레이션 및 실험을 진행하였다. 자여자 유도발전기의 구동 조건에 대해서 언급하고 이를 파라미터에 따라 3-D map으로 만들었다. 또 회로 중의 FET 게이트에 전압을 인가하는 제어장치의 구동펄스에 따라 바뀌는 공진회로의 전압을 분석하였으며, 이 전압을 제어하기 위하여 PI 제어기를 이용한 알고리즘을 제안하였다. 이 전압을 3상 AC/DC컨버터를 통과한 후 DC/DC컨버터를 통하여 차량 내부의 배터리에 충전되는데 제어를 위해 3상 AC/DC에서의 전압 리플을 MA(Moving Average) 방식의 필터를 사용하여 DC/DC컨버터의 입력에 맞도록 제어하였다. 이와 같이 전자기형 리타더에서 유도되는 전압을 제어기의 제어 펄스에 따라 제어할 수 있으며 Matlab Simulink를 이용하여 리타더의 모델과 그 제어기의 타당성을 보였다. 또 실제 M-G Set 실험을 통하여 그 연관성을 확인하였다.

  • PDF

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.