부하를 분담하고 있는 디젤발전기의 무한대 모선과의 병렬운전 시스템 (Parallel Running System of the Loaded Diesel Generator to Infinite Bus)

  • 천행춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.1017-1025
    • /
    • 2004
  • Generally generator is connected to the bus with no load. After the connection to the bus. the frequency of generator system with no load has to be increased for preventing the reverse power. But in a few case of parallel running with infinite bus system, we have to synchronize the loaded generator to the infinite bus. The frequency of generator system with load has to be lowered for prevention of load shift to the bus system. The blackout of infinite bus decreases the parallel running generator's frequency because of load increasing. In this paper we propose a method that the generator with load maintains the frequency constantly after the blackout of infinite bus. With the constant speed control and load control method of parallel running system to the infinite bus we apply the method to the industrial generating system.

LNGC용 Power Generator 모델링 및 시뮬레이션 (Power Generator Modeling and Simulation for LNGC)

  • 황준태;홍석윤;권현웅;이광국;송지훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.297-299
    • /
    • 2016
  • 본 논문에서는 MATLAB/SIMULINK 기반의 LNG 선박용 Power Generator 모델링을 수행하고 시뮬레이션 결과 모니터링이 가능한 인터페이스를 구현하였다. Power Generator의 주요 구성은 기계적 동력을 공급하는 엔진부(Diesel 엔진, Turbine 엔진)와 기계적 동력을 받아 전력을 생산 및 공급을 하는 동기발전기가 있다. 또한, 단일 용량을 초과하는 전체 부하를 공유하기 위해 병렬 연결된 Generator의 Load Sharing과 선박의 가상 부하에 따른 시뮬레이션을 수행하였다. 시뮬레이션 결과와 가상 부하에 따른 예상 결과의 비교를 통해 Power Generator 모델링의 신뢰성을 검증하였다.

  • PDF

부하차단시험에 의한 서인천복합화력 발전기.제어계의 모델링 및 검증 (Modeling and verification of generator/control system of Seo-Inchon combined-cycle plant by load rejection test)

  • 최경선;문영환;김동준;추진부;류승헌;권태원
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.501-510
    • /
    • 1996
  • The gas-turbine generator of Seo-Incheon combined-cycle plant was tested for derivation of a model for dynamic analysis. Load rejection and AVR step test was performed to get the dynamic response of generator. The parameters of generator/control system model were determined by these measured data. No-load saturation test was performed for the saturation characteristics of the generator under steady state. V-curve test was also performed so as to find exact generator parameters. Q-axis parameters of generator was derived by measuring power angle. AVR and governor constants have been tuned by their oscillatory period and setting time characteristics. The derived parameters of generator control system is verified by one-machine infinite bus system simulation. (author). 7 refs., 20 figs., 5 tabs.

  • PDF

부성부하와의 발진을 고려한 단극발전기 시스템 설계 (A Design of Homopolar Generator System Considering Instability with Negative Characteristics Load)

  • 김인수;성세진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.449-451
    • /
    • 2008
  • This paper studies the instability between homopolar generator and constant power load with negative impedance characteristics, provides the design method of homopolar generator system which overcomes the instability. In case of magnitude and phase of impedance of source and load mismatch, control instability of source can occur. For the safety of phase of load impedance, the gain of P, I controller with sufficient phase margin is applied through analysis on the simulation model of generator system, and the gain limit of load impedance is ensured by limitation of the gain margin of generator system. The stability of power system can be increased by considering and analyzing the impedance of source and load.

  • PDF

직통직권 발전기에 의한 직통분권 전동기의 특성해석 (Analysis of D-C Shunt Motor Characteristics, driving D-C Series Generator)

  • 이승원;한송엽
    • 전기의세계
    • /
    • 제16권1호
    • /
    • pp.7-13
    • /
    • 1967
  • There are many kinds of motors operating by rated voltage which is constant. In this paper, the characteristics of separately excited direct current motor is analyzed when its terminal voltage is varied as its load current. As for this source, direct current generator of a series field is used, and it is driven at constant speed by a primemover. The induced voltage of the generator is propotional to its load current but it saturates as its load current is large. The charateristics of motor is studied by analog computer because of the nonlinearity of generator. The results are as follows: (1) The load current and the rotor speed of motor increase as the load of motor increases. But the speed of rotor decreases for the influence of the saturation of the iron of generator field when its load current is large. (2) Decreasing the inertia of motor and increasing the inductance of the armature circuit improve the stability of motor and the region of stable state. (3) By changing the field current of the motor, the speed and the direction of rotor can be controlled in wide range.

  • PDF

Load Test Simulator Development for Steam Turbine-Generator System of Nuclear Power Plant

  • Jeong, Chang-Ki;Kim, Jong-An;Kim, Byung-Chul;Choi, In-Kyu;Woo, Joo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1384-1386
    • /
    • 2005
  • This paper focuses on development of load test simulator of a steam turbine-generator in a nuclear power plant. When load is taken off from electrical power network, it is very difficult to effectively control the steam flow to turbine of the nuclear turbine-generator, because of disturbances, such as electrical load and network unbalance on electrical network. Up to the present time, the conventional control system has been used for the load control on nuclear steam generator, owing to the easy control algorithms and the advantage which have been proven on the nuclear power plant. However, since there are problems with stability control during low power and start-up, only a highly experienced operator can operate during those procedures. Also, a great deal of time and an expensive simulator is needed for the training of an operator. The KEPRI is developed simulator for 600MW nuclear power plant to take a test of generator load rejection, throttle valve, and turbine load control. Total load test is implemented before start up.

  • PDF

불평형 부하 운전시 3상 유도발전기 특성 해석 (Characteristics Analysis of 3-phase Induction Generator at the Unbalanced Load Operation)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제56권3호
    • /
    • pp.123-128
    • /
    • 2007
  • Hydro power supplies no pollution energy, mainly induction generator has been applied at the small capacity power station. The generating power of small hydro-electric power station connects on the 22.9kV distribution system or low voltage system in the case of three-phase four-wire supply system. There are side effects of various kinds in the 3-three phase 4-wire distribution system mixing 1-phase load and 3-phase load. This system generates the voltage unbalance by unbalanced load operating condition. They have various serious effects on generator and connection system. In this paper, we analyzed what kind of operation characteristic are happened in the induction generator by customer load variation at the 3-three phase 4-wire distribution system.

우리나라 계통의 주파수응답특성에 의한 발전기정수 산정에 관한 연구 (Assessment of the Generators Constant from Frequency Response Properties of Korean Power System)

  • 정봉상;전영환;김일동;양정재
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.688-693
    • /
    • 2009
  • The response characteristics of power system frequency are determined by generator droop characteristics and load damping properties. The characteristics of governor droops are termed by generators constant, while those of load damping by load constant. In this paper, the generator constant and the load constant are assessed by measured data at the event of generator trips.

3D electromagnetic design and electrical characteristics analysis of a 10-MW-class high-temperature superconducting synchronous generator for wind power

  • Kim, J.H.;Park, S.I.;Le, T.D.;Kim, H.M.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권2호
    • /
    • pp.47-53
    • /
    • 2014
  • In this paper, the general electromagnetic design process of a 10-MW-class high-temperature superconducting (HTS) synchronous generator that is intended to be utilized for large scale offshore wind generator is discussed. This paper presents three-dimensional (3D) electromagnetic design proposal and electrical characteristic analysis results of a 10-MW-class HTS synchronous generator for wind power. For more detailed design by reducing the errors of a two-dimensional (2D) design owing to leakage flux in air-gap, we redesign and analyze the 2D conceptual electromagnetic design model of the HTS synchronous generator using 3D finite element analysis (FEA) software. Then electrical characteristics which include the no-load and full-load voltage of generator, harmonic contents of these two load conditions, voltage regulation and losses of generator are analyzed by commercial 3D FEA software.

피드포워드 제어기를 사용한 동기발전기의 과도특성 개선 (Improvement of Transient Performance of Synchronous Generator using Feedforward Controller)

  • 안영주
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.57-62
    • /
    • 2018
  • A brush-less type synchronous generator driven by an internal-combustion engine is used for emergency electric source. These types of generators have to maintain a certain range of output voltage even under the sudden load change conditions such as full load application and removal. This paper describes a method for suppressing the output voltage of a synchronous generator that operates excessively when the load fluctuates. The method used in this paper is a feedforward control method in which the main voltage control consists of a feedback loop using a typical PID controller and the load current is detected as a disturbance element and compensated directly. A feedforward system is constructed in which the load current is regarded as disturbance, and the appropriate feedforward controller configuration and parameters are found through simulation. Finally, it can be seen through the experiment that the feedforward control is performed properly. It can be seen that the generator terminal voltage is recovered to the steady state in a short period of time as compared with the existing PID control method even when the entire load of the generator is changed.