• 제목/요약/키워드: Generator Protection

검색결과 271건 처리시간 0.031초

D-q Equivalent Circuit-based Protection Algorithm for a Doubly-fed Induction Generator in the Time Domain

  • Kang, Yong-Cheol;Kang, Hae-Gweon;Lee, Ji-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.371-378
    • /
    • 2010
  • Most modern wind turbines employ a doubly-fed induction generator (DFIG) system due to its many advantages, such as variable speed operation, relatively high efficiency, and small converter size. The DFIG system uses a wound rotor induction machine so that the magnetizing current of the generator can be fed from both the stator and the rotor. We propose a protection algorithm for a DFIG based on a d-q equivalent circuit in the time domain. In the DFIG, the voltages and currents of the rotor side and the stator side are available. The proposed algorithm estimates the instantaneous induced voltages of magnetizing inductance using those voltages and currents from both the stator and the rotor sides. If the difference between the two estimated induced voltages exceeds the threshold, the proposed algorithm detects an internal fault. The performance of the proposed algorithm is verified under various operating and fault conditions using a PSCAD/EMTDC simulator.

d-q 등가회로를 이용한 이중여자 유도발전기 보호 (Protection for DFIG using the d-q Equivalent Circuit)

  • 강용철;이지훈;강해권;장성일;김용균;박군철
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2173-2178
    • /
    • 2008
  • A doubly-fed induction generator(DFIG) system has been widely used in the modem wind turbines due to variable-speed operation, high efficiency and small converter size. It is well known that an inter-turn fault of a generator is very difficult to be detected. The DFIG system uses a wound rotor induction machine so that the magnetizing current of the generator can be fed from both the stator and the rotor. This paper proposes a protection algorithm for a DFIG using the d-q equivalent circuit in the time domain. In the case of a DFIG, the voltages and currents of the rotor side as well as the voltages and currents of the stator are available. The proposed algorithm estimates the instantaneous(i.e., converted into the stationary frame) induced voltages from the rotor and the stator sides. If the difference between the two estimated induced voltages exceeds the threshold, the proposed algorithm detects the inter-turn fault. The algorithm can detect a inter-turn fault of a winding. The performance of the proposed algorithm is validated using a PSCAD/EMTDC simulator under inter-turn fault conditions and normal operating conditions such as an external fault and the change of the wind speed.

발전기의 고장 판별을 위한 웨이브릿 변환의 적용 (Application of Wavelet Transform for Fault Discriminant of Generator)

  • 박철원
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.35-40
    • /
    • 2015
  • Generators are the most complex and expensive single element in a power system. The generator protection relays should to minimize damage during fault states and must be designed for maximum reliability. A conventional CDR(Current Differential Relaying) technique based on DFT(Discrete Fourier Transform) filter have the disadvantages that the time information can lead to loss in the process of converting the signal from the time domain to the frequency domain. A WT(Wavelet transform) and WT analysis is known that it is possible with the local analysis of the fault and transient signal. In this paper, to overcome the defects in the DFT process, an application of WT for fault detection of generator is presented. This paper describes an selection of mother Wavelet to detect faults of generator. Using collected data from the fault simulation with ATPdraw, we analyzed the several mother Wavelet through the course of MLD(multi-level decomposition) using MATLAB software. Finally, it can be seen that the proposed technique using detail coefficient of Daubechies level 2 which can be fault discriminant of generator.

Protection for a Wind Turbine Generator in a Large Wind Farm

  • Zheng, Tai-Ying;Kim, Yeon-Hee;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.466-473
    • /
    • 2011
  • This paper proposes a protection algorithm for a wind turbine generator (WTG) in a large wind farm. To minimize the outage section, a protection relay for a WTG should operate instantaneously for an internal fault or a connected feeder fault, whereas the relay should not operate for an internal fault of another WTG connected to the same feeder or an adjacent feeder fault. In addition, the relay should operate with a delay for an inter-tie fault or a grid fault. An internal fault of another WTG connected to the same feeder or an adjacent feeder fault, where the relay should not operate, is determined based on the magnitude of the positive sequence current. To differentiate an internal fault or a connected feeder fault from an inter-tie fault or a grid fault, the phase angle of the negative sequence current is used to distinguish a fault type. The magnitude of the positive sequence current is then used to decide either instantaneous operation or delayed operation. The performance of the proposed algorithm is verified under various fault conditions with EMTP-RV generated data. The results indicate that the algorithm can successfully distinguish instantaneous operation, delayed operation, or non-operation depending on fault positions and types.

EMP 방호성능 시험용 통합형 E1 펄스 발생장치 분석 및 성능 개선 (Analysis and Performance Improvement of Integrated E1 Pulse Generator for EMP Protection Performance Test)

  • 김영진;강호재;정영경;윤동기;박용배
    • 한국전자파학회논문지
    • /
    • 제29권6호
    • /
    • pp.415-423
    • /
    • 2018
  • 본 논문에서는 HEMP(High-altitude Electromagnetic Pulse)와 같은 외부전자파 환경에 노출된 EMP 방호시설에 연결된 전송선로에 유기된 HEMP 위협에 대한 전도성 방호 성능 평가를 위한 E1 펄스에 대해 연구한다. 기존 E1 펄스 발생장치는 Marx Generator 고전압 승압 방식을 사용하지만, 본 연구에서는 광대역 출력전압(30~350 kV) 가변이 용이한 Tesla Transformer 방식을 사용한다. E1 펄스 발생장치의 구성 요소인 제어기, 전원장치, 고전압 승압장치, 펄스성형장치도 각각 분석한다. Tesla Transformer를 이용한 E1 펄스는 시뮬레이션을 통해 성능을 예측하고, 실제 개발된 장비를 이용하여 결과를 검증한다.

교류발전기 보호를 위한 고장검출 알고리즘의 비교 분석 (A Comparative Analysis of fault Detection Algorithm for AC Generator Protection)

  • 박철원;신광철;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.75-77
    • /
    • 2007
  • Current percentage differential relaying has been recognized as the principal basis of main protection for stator windings of AC generator. The DWT has merit of obtaining frequency characteristics in time domain. In order to compensate for DFT's defects, we proposed fault detection algorithm using DWT. This paper describes a comparative analysis about conventional DFT-based DFR and advanced DWT-based relaying.

  • PDF

분산형전원이 도입된 배전계통에 대한 ISLANDING DETECTION METHOD (Islanding Detection Method of Embedded Generator connected to Power Distribution System)

  • 황진수;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.522-524
    • /
    • 2000
  • The installation of small sized Embedded Generator(EG) in parallel with the utility supply was required several technical complications for protection of the system. One of the most important protection is to provide protection against islanding and out of synchronism reclosing with the utility source. This paper explains several current methods of detecting 'Loss Of Mains'(LOM). But they have not proved completely dependable, in particular when the islanded load's capacity matches that of the EG. A new loss of mains protection algorithm is presented in this paper which based on measurement of the reactive power and node voltage for detecting the islanding condition even though the EG operate in the capacity.

  • PDF

마코프 모델을 이용한 방사선 방어의 최적화 (Optimization of Radiation Protection Using Markov Model)

  • 정진엽;이건재
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.1-9
    • /
    • 1989
  • 방사선 방어를 위한 방안을 결정하는데 도움을 주기 위해서는 각종 방사선 방어 최적화 방안들 사이에 정량적인 비교를 할 수 있는 해석적 방법이 필요하다. 본 논문에서는 발전소에서 행해지고 있는 검사, 시험 및 보수가 방사선 방어에 미치는 영향을 평가할 수 있는 동적 마코프 모델의 개념을 도입하였다. 마코프 모델의 응용을 다루기 위해 예로 든 증기발생기 전열관 파열에서는 고리 2호기와 외국의 자료에 기초해 비용과 피폭 선량을 줄이기 위한 증기발생기의 최적 검사주기를 산출하였으며 그 결과 피폭 선량은 비용에 비해 그 기여도가 매우 낮은 것으로 나타났다. 예제 계산이 이용된 마코프 모델은 자료를 좀 더 보강함으로써 국내 발전소에도 쉽게 적용할 수 있으며 방사선 방어의 최적화를 위한 여러 가지 대안의 비교 우위를 평가하는 데에도 이용할 수 있다.

  • PDF

하이브리드형 고효율 자가 발전기를 위한 시스템에 관한 연구 (A hybrid study on self-generators based on system for high-efficiency)

  • 정양권;엄태현;김기훈;황훈
    • 한국전자통신학회논문지
    • /
    • 제6권6호
    • /
    • pp.897-902
    • /
    • 2011
  • 본 연구는 용접기와 발전기를 통합하여 필요에 따라 발전기로 사용하다가 용접기로 사용할 수 있도록 시스템을 구성하는 것이다. 이와 같이 통합 시스템을 제안하기 위해서는 급속충전이 진행되지 않도록 전력 상태 정보를 관리하는 시스템 구성이 가장 중요하다. 가장 이상적인 충전은 임의로 전류를 조절하는 것이 가장 이상적이다. 충전은 가급적 적은 전류로 오래하면 좋지만 본 연구에서는 용접기와 발전기를 가장 이상적으로 융합하여 필요에 따라서 발전기 또는 용접기로 활용할 수 있는 시스템을 제안하고자 한다. 특히 사용자의 부주의로 인한 손상이 발생할 수 있게 되므로 회로 단락 보호, 과부하 보호, 역극성 보호, 자동 충전 조정 기능을 포함한 시스템에 관한 것이다.