• Title/Summary/Keyword: Generation Quantity

Search Result 313, Processing Time 0.022 seconds

Characteristics of Water Surface Discharge due to Water Conductivity (수증 전도도 변화에 따른 수표면 방전의 특성)

  • 박승록;김진규;김형표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.44-48
    • /
    • 2004
  • A silent type ozone generator using water surface electrode was proposed. And it was investigated experimentally that a variation of water conductivity affected to water surface discharge. Important factors affecting to water surface discharge are ions in discharge space and ions and polarized molecules in water and so on. In this study, It was intended to change the characteristics of discharge by controlling the number of ions in water. The number of ions in water could be controlled by changing the water conductivity. Water conductivity was controlled by quantity of inserted NaCl to distilled water. At this time, current-voltage characteristics and characteristics of ozone generation quantity were investigated in each case. As a result, when NaCl was inserted in distilled water, more stable discharge was generated. As the quantity of NaCl was increased, discharge starting voltage could be lowered.

Evaluation of Long-term Contracts for Market Power Mitigation in Generation Markets (발전력 시장에서의 시장지배력 억제를 위한 장기 계약량 산정에 관한 연구)

  • Song Kwang Jae;Hur Don;Nam Young Woo;Park Jong Keun;Jeong Hae Seong;Yoon Yong Tae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.38-42
    • /
    • 2005
  • Restructuring of the electric power industry has brought the issue of market competitiveness to surface. Recent years have witnessed the appearance of a particular seller or group of sellers exercising market power in electricity supply. In fact, much scholarly work has been done on how to identify and mitigate such abuse by market management rules. In this paper we assess the possible market power on the basis of pivotal supplier test and propose the method to determine the reasonable quantity of long-term contracts which can play a crucial role in mitigating the market power for a pivotal player. Furthermore the market efficiency is guaranteed by making long term contracts with a pivotal player up to the quantity to ensure that the pivotal player has no incentive to abuse the pivotal quantity in the electricity market.

Ni Electroplating in the Emulsions of Supercritical $CO_2$ Formed by Ultrasonar (초음파를 이용한 초임계 이산화탄소 에멀젼내 Ni 전해도금)

  • Koh M. S.;Joo M. S.;Park K. H.;Kim H. D.;Kim H. W.;Han S. H.;Sato Nobuaki
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.6
    • /
    • pp.344-349
    • /
    • 2004
  • Emulsions were formed through putting small quantity of nickel electroplating solution into supercritical carbon dioxide, and then electroplating in the $sc-CO_2$ emulsions was conducted. It is an environmental-friendly technology that can solve the treatment of a large quantity of toxic plating wastewater, which is a big problem in the existing wet plating, and also can reduce secondary waste generation fundamentally. Supercritical carbon dioxide emulsions enhanced by ultrasonic horn were formed by non-ionic surfactant and nickel solution. Plating condition within emulsions was set up as 120bar and $55^{\circ}C$ through measurement of electrical conductivity following the pressure change. Experiments were conducted respectively against supercritical carbon dioxide emulsions electroplating and general chemical electroplating, and then their results were compared and analyzed. As the experiment result utilizing emulsions, plating surface was formed very evenly even with a small quantity of electroplating solution, and fine particles were plated compactly without any pinhole or crack due to hydrogenation, which occurs in general electroplating. Used electroplating solution can be reused through recovery process. Therefore, this technology will be able to be applied as new clean technology in electro-plating.

On the Performance Improvement of the Diesel Engine by Uitrasonic Treatment of Fuel Oil (연료유의 초음파 처리에 의한 디젤기관의 성능향상에 관한 연구)

  • 양정규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.2
    • /
    • pp.191-196
    • /
    • 1992
  • This paper is an experimental study to investigate utility of ultrasonic treatment of fuel oil in diesel engine. Experiment was carrid out to clarify the effect of ultrsonic vibration on the characteristics of maximum pressure, fuel consumption ratio, smoke, BMEP and torque. The result obtained are as follows: 1. In the case of given ultrsonic vibration, the maximum pressure is increased in all experimental conditions. 2. In the case of given ultrsonic vibration, the decrease effect of fuel consumption rate is increased at low rpm. 3. The generation quantity of soots is increased according to load. In the case of given ultrsonic vibration, the decreased quantity of soots does not very according to load. 4. In the case of given ultrsonic vibration, the BMEP and torque are increased at low load.

  • PDF

Characteristics of a Superposed Discharge Type Ozonizer(III) (중첩방전형 오존방생기의 특성(III))

  • Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In;Kim, Gi-Chae;Lee, Dong-Heon;Kim, Geum-Young;Lee, Chun-Ha;Jeun, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1815-1817
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer(IESDO) has been designed and manufactured. IESDO is equipped with three electrodes(central, internal and external electrodes), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. This paper describes the following characteristics : (1) The characteristics of discharge with variation of output voltage of AC H.V source, quantity of supplied gas and discharge voltage (2) the characteristics of ozone generation with variation of quantity of supplied gas, discharge power, operating number of IESDO.

  • PDF

A Characteristics of UV images and PD quantity at Needle-Plane electrodes (침대평판 전극에서의 부분방전량과 자외선 이미지 특성)

  • Shong, Kil-Mok;Kim, Young-Seok;Park, Sang-Taek
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.101-104
    • /
    • 2009
  • In this paper, it's described the techniques for the analysis of corona generated in open live parts of electric facilities. At needle-plane electrodes, when the voltage increased($0{\sim}70kV$, ramping 10kV) using the high voltage generation system(HIPOTRINICS $0{\sim}200kV$, USA), it's generated the partial discharge. There are compared between UV detected image and PD quantity. As these results, UV areas and gains are normalized. And electric facilities are evaluated the 5 steps such as 'good', 'recognition', 'check', 'inspection', 'change(replacement)'.

  • PDF

A Study on the Prediction of HLW Temperature from Natural Ventilation Quantity using CFD (전산유체학을 이용한 고준위 방사성 폐기물 처분장의 자연환기량에 의한 온도예측)

  • Roh, Jang-Hoon;Yu, Yeong-Seok;Jang, Seung-Hyun;Park, Seon-Oh;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.22 no.6
    • /
    • pp.429-437
    • /
    • 2012
  • This study predicted temperature in the disposal tunnels using computational fluid dynamics based on natural ventilation quantity that comes from high altitude and temperature differences that are the characteristics of high level waste repository. The result of the previous study that evaluated quantitatively natural ventilation quantity using a hydrostatic method and CFD shows that significant natural ventilation quantity is generated. From the result, this study performed the prediction of temperature in disposal tunnels by natural ventilation quantity by the caloric values of the wastes, at both deep geological repository and surface repository. The result of analysis shows that deep geological repository is effective for thermal control in the disposal tunnels due to heat transfer to rock and the generation of sufficient natural ventilation quantity, while surface repository was detrimental to thermal control, because surface repository was strongly affected by external temperature, and could not generate sufficient natural ventilation quantity. Moreover, this study found that in the case of deep geological repository with a depth of 200 m, the heatof about $10^{\circ}C$ was transferred to the depth of 500 m. Thus, it is considered that if the high level waste repository scheduled to be built in the country is designed placing an emphasis on thermal control, deep geological repository rather than surface repository is more appropriate.

Estimation of Methane Generation Rate and Potential Methane Generation Capacity at Cheongju Megalo Landfill Site Based on LandGEM Model (LandGEM 모델을 이용한 청주권 생활폐기물 매립장의 매립지가스 발생상수 및 메탄 잠재발생량 산정)

  • Hong, Sang-Pyo
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.6
    • /
    • pp.414-422
    • /
    • 2008
  • Methane is a potent greenhouse gas and methane emissions from landfill sites have been linked to global warming. In this study, LandGEM (Landfill Gas Emission Model) was applied to predict landfill gas quantity over time, and then this result was compared with the data surveyed on the site, Cheongju Megalo Landfill. LandGEM allows the input of site-specific values for methane generation rate (k) and potential methane generation capacity $L_o$, but in this study, k value of 0.04/yr and $L_o$ value of $100\;m^3$/ton were considered to be most appropriate for reflecting non-arid temperate region conventional landfilling like Cheongju Megalo Landfill. Relatively high discrepancies between the surveyed data and the predicted data about landfill gas seems to be derived from insufficient compaction of daily soil-cover, inefficient recovery of landfill gas and banning of direct landfilling of food waste in 2005. This study can be used for dissemination of information and increasing awareness about the benefits of recovering and utilizing LFG (landfill gas) and mitigating greenhouse gas emissions.

Estimation of Community-Based Unused Biomass Generation (지역단위 미이용 바이오매스 발생량 추정)

  • Choi, Eun-Hee;Lee, Mun-Yong;Yoon, Young-Man;Kim, Chang-Hyun;Yoon, Sung-Yee
    • Korean Journal of Organic Agriculture
    • /
    • v.20 no.4
    • /
    • pp.447-458
    • /
    • 2012
  • This study was carried out to evaluation of biomass generation mechanisms and to propose the estimation method of biomass generation. Agricultural by-product biomass is generated during crops cultivation and after harvest. However these are not uniformly generated yearly and these depending on the seasons. For planning of biomass utilization, accurate information of the biomass resources is needed, especially characteristic and productivity of biomass are necessary. Agricultural by-product biomass are generated in a wide area being scattered and it is one of the major reason why agricultural biomass utilization is not activated compared with other waste biomass. In this study, estimation and evaluation biomass generation is achieved in specific spatial and temporal boundary, A-city in Gyeongi-do and september to November respectively. Quantity and quality of by-product biomass show big difference depending on the crop species and cultivation periods and these difference bring up that accurate biomass estimation should be considered during planning of biomass utilization and technology selecting for biomass converting to energy and other forms.

Ozone Generation Characteristics by according to the Coaxial Electrode Geometry (동축형 전극구조 변화시의 오존생성 특성)

  • 조국희;이홍식;이형호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.68-74
    • /
    • 2000
  • In this paper the concentration, yield and generation quantity of the ozone by the superposition discharge according to the coaxial electrodes geometry is described. In order to improve the ozone generation, a new type of ozonizer is proposed, where a silent discharge and a surface discharge are generated in the separated discharge spaces at the same time. To investigate the ozone generation dependency on electrode geometry, a few discharge tubes with different geometry were fabricated. In our experiment, the 60[Hz] one phase voltage is applied to the discharge tube which has three electrodes. And three kinds of discharges, two silent discharges and a surface discharge are superposed in the same space of the ozonizer. As a result, the followings are obvious. When two kinds of discharges are superposed under the condition using 3 electrode-3gap discharge tube, the maximum ozone efficiency is obtained.

  • PDF