• Title/Summary/Keyword: Generation Interval

Search Result 242, Processing Time 0.027 seconds

GENERATION OF AN IMPERVIOUS MAP BY APPLYING TASSELED-CAP ENHANCEMENT USING KOMPSAT-2 IMAGE

  • Koh, Chang-Hwan;Ha, Sung-Ryong
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.378-381
    • /
    • 2008
  • The regulating and relaxing targets in the Land Use Regulation and Total Maximum Daily Loads are influenced by Land cover information. For the providing more accurate land information, this study attempted to generate an impervious surface map using KOMPSAT-2 image which a Korea manufactured high resolution satellite image. The classification progress of this study carried out by tasseled-cap spectral enhancement through each class extraction technique neither existing classification method. KOMPSAT-2 image of this study is enhanced by Soil Brightness Index(SBI), Green vegetation Index(GVI), None-Such wetness Index(NWI). Then ranges of extracted each index in enhanced image are determined. And then, Confidence Interval of classes was determined through the calculating Non-exceedance Probability. Spectral distributions of each class are changed according to changing of Control coefficient(${\alpha}$) at the calculated Non-exceedance Probability. Previously, Land cover classification map was generated based on established ranges of classes, and then, pervious and impervious surface was reclassified. Finally, impervious ratio of reclassified impervious surface map was calculated with blocks in the study area.

  • PDF

A Study on Forecasting Method for a Short-Term Demand Forecasting of Customer's Electric Demand (수요측 단기 전력소비패턴 예측을 위한 평균 및 시계열 분석방법 연구)

  • Ko, Jong-Min;Yang, Il-Kwon;Song, Jae-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • The traditional demand prediction was based on the technique wherein electric power corporations made monthly or seasonal estimation of electric power consumption for each area and subscription type for the next one or two years to consider both seasonally generated and local consumed amounts. Note, however, that techniques such as pricing, power generation plan, or sales strategy establishment were used by corporations without considering the production, comparison, and analysis techniques of the predicted consumption to enable efficient power consumption on the actual demand side. In this paper, to calculate the predicted value of electric power consumption on a short-term basis (15 minutes) according to the amount of electric power actually consumed for 15 minutes on the demand side, we performed comparison and analysis by applying a 15-minute interval prediction technique to the average and that to the time series analysis to show how they were made and what we obtained from the simulations.

Optimal Operation by integrating Sihwa Power into NamSihwa Systems (시화조력발전 연계에 의한 남시화 계통의 최적 운영 방안)

  • Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.120-126
    • /
    • 2009
  • This paper presents an optimal operating scheme by integrating Sihwa tidal power into NamSihwa systems. For optimal operation of NamSihwa systems, the sea levels of 1 minute interval using cubic interpolation based on the forecasted levels of high and low water are calculated. Especially, it is compared by three schemes to purchase total power from transmission system to purchase total power from tidal power system in time period that can generate tidal power and to purchase total power by comparing purchase costs from transmission system and tidal power system. The scheme may contribute to energy save in Korea that natural resources are lacking.

A case study on the implementation and performance evaluation of profibus network in automation systems (자동화 시스템에서 Profibus 네트워크 인터페이스 구현 및 성능 평가)

  • Kim, Ki-Am;Hong, Seung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.1
    • /
    • pp.113-122
    • /
    • 1998
  • This paper presents an implementation method of Profibus interface software using FMS(Fieldbus Message Specification). The Profibus interface software is implemented on PC which is widely used as an industrial computer as well as a commercial embedded controller called IUC(Intelligent Universal Controller). In order to enable the Profibus interface software to handle many application tasks and communication services, two kinds of real-time/multi-tasking operating system, OS-9 and CTask, are utilized. We also develop an experimental model of Profibus-based automation system, and evaluate the performance of the Profibus network. Through experiments, the user layer level message latency is measured with respect to the change of message length, message generation interval and TRT(Target Rotation Time). The results of experiment are compared with those of a simulation model which comprises only the physical and data link layers of Profibus. The results of this study shows that the message latency in the user layer level occupies fairly a large part of the total message latency.

  • PDF

Effect of Ophthalmic Fluoroquinolones on Bacterial Conjunctivitis: Systematic Review (세균성결막염에 대한 안과용 플루오로퀴놀론계 항균제의 효과: 체계적문헌고찰)

  • Sohn, Hyun-Soon
    • YAKHAK HOEJI
    • /
    • v.55 no.1
    • /
    • pp.22-31
    • /
    • 2011
  • This systematic review was conducted to assess the clinical effect of ocular fluoroquinolones used for the treatment of bacterial conjunctivitis. A literature search for randomized controlled clinical trials registered up to January 2010 based on PubMed database, using the following search terms: conjunctivitis and fluoroquinolones (besifloxacin, moxifloxacin, gatifloxacin, levofloxacin, lomefloxacin, ciprofloxacin and ofloxacin) were performed. Pooled data on the clinical resolution and bacterial eradication rates derived from selected 16 studies were reported as the relative risk (RR) and 95% confidence interval (95% CI) compared with placebo. Early clinical resolution and microbiological eradication rates in placebo were 28% and 62% respectively. Fluoroquinolones were significantly effective comparing to placebo: early RR 1.94 (95% CI 1.60~2.34) and late RR 1.30 (1.19~1.43) in clinical resolution rates, and early RR 1.75 (1.58~1.94) and late RR 1.28 (1.18~1.39) in microbiological eradication rates. Besifloxacin, ciprofloaxain and moxifloxacin in clinical resolution, and besifloxacin and levofloxacin in microbiological eradication showed higher RRs than pooled overall fluoroquinolones' RRs. New quinolones had higher antibacterial potencies for all pathogens isolated from bacterial conjunctivitis and resistant isolates than old generation quinolones. In conclusion, ocular 7 fluoroquinolones were all effective than placebo for bacterial conjunctivitis and there were differences between quinolones in early and late clinical resolutions and microbiological eradications, and no differences in safety comparing to placebo.

The Analysis of maximum output power of PV module by solar cell Interval (PV모듈에서 태양전지의 간격에 따른 전기적 출력 특성 분석)

  • Lee, Jin-Seob;Kang, Gi-Hwan;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.13-14
    • /
    • 2008
  • In this paper, we analyze the electrical characteristics of PV depending on distance among solar cells before and after lamination process. From the result, the PV module's maximum power increases about 3.37% when solar cells's distance is 10mm. And the maximum power increases up to 8.42% when solar cells's maximum distance is 50mm. It is assumed that PV module's surface temperature decreases because of increasing distance between solar cells that would give high power generation. Also, short distance between solar cell and frame result in contamination on glass. When considering reduced maximum power caused by contaminant, from that, we can fabricated PV module of lower cost with high performance.

  • PDF

Analysis of a Queueing Model with Combined Control of Arrival and Token Rates (패킷 도착률과 토큰 생성률의 통합 관리를 적용한 대기모형의 분석)

  • Choi, Doo-Il;Kim, Tae-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.6B
    • /
    • pp.895-900
    • /
    • 2010
  • As the diverse telecommunication services have been developed, network designers need to prevent congestion which may be caused by properties of timecorrelation and burstiness, and unpredictable statistical fluctuation of traffic streams. This paper considers the leaky bucket scheme with combined control of arrival and token rates, in which the arrival rate and the token generation interval are controlled according to the queue length. By using the embedded Markov chain and the supplementary variable methods, we obtain the queue length distribution as well as the loss probability and the mean waiting time.

A Study on an Operating Conditions for the Direct Ethanol Fuel Cell (직접에탄올 연료전지의 운전조건에 관한 연구)

  • Kim, Young-Chun;Koo, Bon-Kook;Jang, Mun-Gug;Ji, Hag-Bae;Han, Sang-Bo;Park, Jae-Youn
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2076-2082
    • /
    • 2011
  • The goal of this paper is to find an operating conditions of the single direct ethanol fuel cell such as the cell temperature, and flow rates of ethanol and oxygen. To investigate the output characteristics, the electrical current increased from 0[A] with interval of 0.001[A] every 2[s], and the cell voltage was increased until the voltage became 0.05[V]. Related to the effect of the cell temperature, the output characteristics both voltage and power were increased upto 80[$^{\circ}C$] according to the increase of the current density, but those were decreased over that temperature. In addition, the optimal flow rate of ethanol in anode was identified as of 2[mL/min] due to the dependence of generation rate such as the hydrogen ion and electron. And the flow rate of oxygen in cathode was desirable to about 300[sccm/min], it might be affected by the chemical reaction rate of the water formation among hydrogen ion, electron, and oxygen. Consequently, the fundamental conditions were identified in this work, and it will be carried out to find the best conditions of membrane by the effect of the plasma surface treatment, and the effect of other catalysts except for a platinum.

Generating Large Items Efficiently For Mining Quantitative Association Rules (수량적 연관규칙탐사를 위한 효율적인 고빈도항목열 생성기법)

  • Choe, Yeong-Hui;Jang, Su-Min;Yu, Jae-Su;O, Jae-Cheol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.10
    • /
    • pp.2597-2607
    • /
    • 1999
  • In this paper, we propose an efficient large item generation algorithm that overcomes the problem of the existing algorithm for making large items from quantitative attributes. The proposed algorithm splits dataset into variable size of intervals by min_split_support and merges the intervals according to the support of each interval. It reflects characteristic of data to generated large items and can generate finer large items than the existing algorithm. It is shown through the performance evaluation that our proposed algorithm outperforms the existing algorithm.

  • PDF

Characterization of Quantitative Trait Loci (QTL) for Growth using Genome Scanning in Korean Native Pig

  • Lee, H.K.;Choi, I.S.;Choi, B.H.;Kim, T.H.;Jung, I.J.
    • Reproductive and Developmental Biology
    • /
    • v.28 no.2
    • /
    • pp.107-112
    • /
    • 2004
  • Molecular genetic markers were genotyped used to detect chromosomal regions which contain economically important traits such as growth traits in pigs. Three generation resource population was constructed from a cross between the Korean native boars and Landrace sows. A total of 193 F2 animals from intercross of F1 were produced. Phenotypic data on 7 traits, birth weight, body weight at 3, 5, 12, 30 weeks of age, live empty weight were collected for F2 animals. Animals including grandparents (F0), parents (F1), offspring (F2) were genotyped for 194 microsatellite markers covering from chromosome 1 to 18. Quantitative trait locus analyses were performed using interval mapping by regression under line-cross model. To characterize presence of imprinting, genetic full model in which dominance, additive and imprinting effect were included was fitted in this analysis. Significance thresholds were determined by permutation test. Using imprinting full model, four QTL with expression of imprinted effect were detected at 5% chromosome-wide significance level for growth traits on chromosome 1, 5, 7, 13, 14, and 16.