흉부 방사선검사에서 자동노출제어 사용에 관한 연구 (A Study on the Using of Automatic Exposure Control in the Chest Radiography)

  • 최성식;임청환;정성훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권1호
    • /
    • pp.19-24
    • /
    • 2019
  • For general radiological examinations, even in the same area and the same test, the test conditions must be set differently according to the patient. However, since it is impossible to consider the body shape and conditions of patients every time in medical institutions where various patients visit, the tests are conducted by setting the AEC which automatically sets the test conditions. AEC is most commonly used in chest radiography. Therefore, the purpose of this study is to propose the improvement plans for using AEC by measuring the exposure dose and evaluating the image quality according to whether the AEC is used or not, and to provide basic data for AEC research. In the present study, images were acquired while varying tube voltage and test distance according to the use of AEC in chest radiography. The radiation dose was measured by placing the dosimeter in front of the chest phantom, and the CNR and SNR of acquired images were analyzed using Image J. The t-test was conducted for the statistical analysis and the significance was determined at the level of 95%(p<.05). As a result of this study, in the inspection distance (100cm, 140cm, 180cm) according to the use of AEC, high doses were observed when the AEC was used and there was statistically significant difference(p<.05). In the t-test to determine the difference between CNR and SNR depending on whether AEC was used or not, there was no significant difference according to the use of AEC(p>.05). Therefore, when performing chest radiography, if the radiologist establishes the appropriate examination conditions and conducts the examination by not just relying solely on AEC, it may be possible to reduce unnecessary radiation exposure to the patient.

부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구 (A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan)

  • 전성오;조영하
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.49-55
    • /
    • 1997
  • This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at $60{\sim}100\;kVp$ and only 14% at 100 kVp and over for the high tube voltage. 3. The average exposure time was less than 0.1 second, and eighty four percent of the units adapted the X-ray tube currents ranging from 200 to 300 mA, 80% the focus-film distances between 180 and 210 cm, and 63% the focus sizes of more than 2.0 mm. 4. Most units(98%) employed additional filters made of aluminum, 75% the thickness of filters less than 2.0 mm, and only 2 units the compound filters. 5. Ortho chromatic system was only adopted in 13% of screen film system for the units, and 73% used the grid ratio at 8 : 1 for the low tube voltage during chest radiography. 6. The average exposure dose of all X-ray units during chest radiography was $371\;{\mu}Sv$ with a difference of about 16 times between the minimum to the maximum, and $386\;{\mu}Sv$ both at hospitals and at health centers, followed by $380\;{\mu}Sv$ at general hospitals and $263\;{\mu}Sv$ at university hospitals without showing any statistically significant differences. In conclusion, since patients during chest radiography at medical facilities in Pusan exposed to high levels of radiation, it is recommended that appropriate added filters and grids necessary for the high tube voltage radiography and high-speed screen systems should be adopted and used as soon as possible in order to reduce exposure dose to the patients.

  • PDF

족근 관절외에 발생한 활액막 연골종증의 치료 - 1예 보고 - (Treatment of Extraarticular Synovial Chondromatosis of the Ankle - A Case Report -)

  • 이원용;박병문;송경섭;임대의;김형규;강영훈
    • 대한족부족관절학회지
    • /
    • 제6권1호
    • /
    • pp.111-116
    • /
    • 2002
  • Synovial chondromatosis is an uncommon benign lesion characterized by metaplastic cartilage formation within the synovial connective tissue, usually intraarticular, commonly affects the knee, hip and elbow. An extraarticular lesion is rare, most often seen in a synovial sheath and bursa of the hand or foot. We present a case of extraarticular synovial chondromatosis in the left ankle, originated from the FHL tendon sheath of a 31 year-old-female diagnosed by a radiography, MRI confirmed histopathologically.

  • PDF

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

치과진단용 X선발생장치의 이용 실태 및 방어에 관한 연구 (The Study on the Protection and Actual Condition of Using the Dental X-ray Unit)

  • 강은주;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.43-54
    • /
    • 2000
  • This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).

  • PDF

방사선검사 시 의료방사선 안전성에 대한 인식도 조사 (Research of Awareness for Medical Radiation Safety in Radiography)

  • 김규형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.255-260
    • /
    • 2018
  • Most patients and parents and guardians display frequent anxiety due to radiation exposure during outpatient, ward, and pediatric general radiographic examinations. This is a behavior that perceives only the harmfulness of radiation. For the recognition of medical radiation, we conduct surveys on outpatients, inpatients, and pediatric parents and guardians to identify their awareness, and then use the radiation dose promotional materials After providing accurate information on the use of radiation, the outpatient, inpatient, and pediatric parents and guardians were asked to explain the change in awareness. The questionnaire items were classified into five categories: repetitive radiation awareness for diagnosis, awareness of exposure dose, availability of exposure information, awareness of radiation risk, and awareness of health problems caused by radiation. There was a statistically significant difference in the items of recognition result of medical radiation, although there was a slight difference in the individual items in the pre and post-recognition results of providing information about the radiologists of the protector and the outpatient(p<0.05). Therefore, through the installation of these promotional materials, we will improve our awareness of medical radiation safety during general radiography surveillance in the Department of Radiology to provide better quality medical information and medical services, thereby contributing to strengthening the competitiveness of the hospital.

나노도트선량계를 이용한 입사표면선량의 평가 (An Assessment of Entrance Surface Dose Using the nanoDot Dosimeter)

  • 김종언;임인철;박철우
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.377-381
    • /
    • 2011
  • 이 연구의 목적은 일반방사선촬영에서 입사표면선량에 대하여 나노도트선량계의 측정값과 Non Dosimeter Dosimetry-Method(NDD-M)의 계산값과 비교 평가하는 데 있다. 입사표면선량들의 측정과 계산은 두부(AP), 복부(AP), 골반(AP), 흉추(AP)와 요추(AP)에 대하여 수행하였다. 결과로서, 계산값에 대한 측정값의 상대비들은 각 부위에 대하여 1.5-2.1을 얻었다. 재현성은 변동계수로서 0.035를 얻었다.

일반촬영분야에서의 3D 프린터로 제작한 텅스텐 혼합 필라멘트 차폐체의 성능평가 (Evaluation of Tungsten Blended Filament Shields Made by 3D Printer in Radiography)

  • 윤준;윤명성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.615-621
    • /
    • 2021
  • In the medical field, radiation provides information for the diagnosis and treatment of diseases. As the use of radiation increases and the risk of exposure increases, interest in radiation protection is also rapidly increasing. Lead shielding material is mainly used, which has a risk of lead poisoning and absorption into the body. Tungsten mixed filament shielding sheets were fabricated with a size of 70 × 70 mm and a thickness of 1, 2, and 4 mm by using a 3D printer. In the general shooting experiment, the thickness of the shielding sheet is 1 ~ 5mm, the tube voltage is 60, 80, 100, 120 kVp and the tube current is 20, 40 mAs. In general photography, Tungsten showed better shielding rate compared to Brass, Copper, and Lead protective tools under all irradiation conditions, and in particular, Tungsten 5 mm showed 100% shielding rate. The 3D-printed tungsten mixed filament shielding is expected to be used as a new shield that can replace the existing lead protection tools as it shows a better shielding rate than the existing lead protection tools in Radiography.

방사선촬영 중 제어실 문의 열린 방향에 따른 차폐효과 (Shielding Effect according to the Direction of Control Room Door Opening during Radiography)

  • 최원근;김정훈;강보선;배석환;임창선
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3347-3352
    • /
    • 2010
  • 방사선촬영검사 시에는 제어실 문을 닫고 촬영하도록 권고하고 있으나 응급 환자나 소아 환자 등의 방사선 촬영검사 시에는 발생할 수 있는 긴급 상황에 대한 신속한 조치 수행을 위해서 불가피하게 제어실 문을 열어 놓은 상태에서 촬영해야 하는 경우가 있다. 또한 일반 단순촬영의 경우에도 환자들의 대기시간 단축 등을 고려할 때 촬영시 제어실 문을 열어 두는 것이 더 효율적일 수 있다. 이러한 상황을 감안하여 제어실 문을 열어 놓고 촬영업무를 수행하는 경우에 방사선작업종사자에 대한 방사선피폭선량을 평가하여 방사선피폭을 최소화하면서 업무의 효율을 올릴 수 있는 방안을 모색하고자 본 연구를 수행하였다. 실제 선량률은 유리선량계를 이용하여 측정하였으며, 제어실 문이 열린 상태에서 촬영 시 방사선작업종사자 위치에서 의 선량률은 주당 100 mR(약 0.88 mGy)을 약 2.3배 초과하는 2.02 mGy가 측정되었다. 이 결과를 통해 문이 열린 경우에는 상당량의 산란선이 작업종사자의 피폭선량을 증가시킴을 알 수 있었으며, 제어실 문이 열린 상태에서 촬영할 경우 작업종사자의 과다피폭 가능성이 매우 높다는 것을 확인하였다. 또한 몬테카를로 전산 모의실험을 수행하여 동일한 조건에서도 제어실 문의 방향에 따라 방사선작업종사자가 위치한 곳의 선량률을 대략 1/100까지 감소시킬 수 있음을 확인하였다. 결론적으로, 제어실 문을 열고 촬영하더라도 제어실 문의 방향에 따라 동일한 차폐효과를 기대할 수 있으므로 방사선차폐시설을 함에 있어 이에 대한 고려가 요구된다.

디지털 방사선 시스템에서 발생하는 Artifact (Artifacts in Digital Radiography)

  • 민정환;김정민;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.375-381
    • /
    • 2015
  • 디지털 방사선 시스템은 영상의학에서 큰 비중을 차지하고 있다. 잘못된 영상이 제공 된다면 이는 환자의 건강에 나쁜 영향을 줄 수 있기에, 올바른 디지털 방사선 영상이 제공되어야만 한다. 또한, artifact는 오진으로 이어질 수 있다. 디지털 방사선 시스템에서 발생하는 artifact를 종류별로 분석하여 그 결과 분석하였다. 본 연구에서 사용된 artifact는 서울의 종합병원 급 의료기관에서 2007년부터 2014년까지 수집된 자료들이다. 수집된 자료는 발생 원인별로 구별하여 그 원인을 분석하였다. artifact는 하드웨어적 artifact, 소프트웨어적 artifact, 사용자 오류, 시스템 artifact 및 기타로 구분하였다. 하드웨어적 artifact는 Ghost가 가장 빈번하게 관찰되었으며, 이는 신호의 잔류에 의한 것이다. 다음은 RF 잡음에 의한 오류, 장비 내 이물질에 의한 오류 순이다. 소프트웨어 artifact는 많은 원인이 있다. 부정확한 영상 교정에 의한 artifact가 가장 많았으며, EDR 인식오류, 접합면 처리 오류 등이 있으며, 소프트웨어 artifact는 매우 다양한 경향을 나타낸다. 사용자 오류는 디지털 의료 영상 시스템을 바르게 이해하지 못해 발생시킨 것들이 많았다. 아울러, 시스템 artifact는 DICOM 헤더 정보 오류, 압축 오류가 있다. 분명하게 나타나는 artifact는 재촬영의 원인이 되어 환자의 피폭을 증가시키고, 불분명하게 나타나는 artifact는 오진을 유발 시킬 수 있다. 따라서 방사선사에게서 이러한 artifact를 바로 구별 할 수 있는 능력이 요구 된다. 그러므로 artifact가 발생되는 원인과 그 특성을 분명하게 이해함으로 지속적인 교육과 안정적인 시스템 운영에 힘써야 할 것으로 사료된다.