• Title/Summary/Keyword: General Performance Test

Search Result 1,202, Processing Time 0.034 seconds

Vibration Control of Tower Structure under Wind Load (풍하중에 의한 타원형 구조물의 진동 제어)

  • Hwang Jae-Seung;Kim Yun-Seok;Joo Seok-Jun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.427-430
    • /
    • 2002
  • The present parer outlines the system identification and vibration control performance of air traffic control tower of Yangyang international airport with tuned mass damper(TMD). From the free vibration test, natural frequency, damping ratio and mode shape of tower are obtained and these values are compared with the values from numerical analysis. In the vibration control test to evaluate the vibration control performance, equivalent damping ratio increased by tuned mass damper are obtained in case the TMD is operated as passive mode. Damping ratio of tower evaluated from free vibration test is about $1.0{\%}$. It is very low value than damping ratio recommended in general code. Damping ratio of passive mode is about $5{\%}$. These equivalent damping ratio increased by TMD is enough to enhance the serviceability of tower structure under wind load.

  • PDF

The Development of Hydraulic-Coupling Experimental Apparatus Using Brake Load and Prediction of Torque Performance (브레이크 부하를 이용한 유체커플링 실험장치 개발과 토크 성능 예측)

  • 박용호;김기홍
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.100-107
    • /
    • 2000
  • The hydraulic couplings have been widely used in industries, automobile, and power-station drives including ships. A mathematical analysis by which the design and application of hydraulic couplings are made is used in conventional design formulae and general roto-dynamic theories. The fluid flow of hydraulic couplings can be considered to have two component, one circumferentially about the coupling axis, and the other passing fluid from the pump to the turbine in the plane of the coupling axis. Tests have been carried out on the full-scale production coupling. The performance test consists of taking measurement of torque of the fluid coupling for three different amount of working fluid inside with various loads to the output shaft. The purpose of this research is to construct the experimental test equipments and to establish a series of performance test for the domestically developed hydraulic couplings, and to obtain experimental results which can be used to improve the performance of the hydraulic coupling and to solve the practical problems confronted in operation.

  • PDF

The Influence of Nurses' Osteoporosis Knowledge and Health Behavior Self-efficacy on Preventive Nursing Performance for Osteoporosis (간호사의 골다공증 지식, 건강행위 자기효능감이 골다공증 예방간호수행에 미치는 영향)

  • Park, Bona;Park, Myung Sook
    • Journal of muscle and joint health
    • /
    • v.28 no.2
    • /
    • pp.192-199
    • /
    • 2021
  • Purpose: This study aimed to identify the influence of osteoporosis knowledge and health behavior self-efficacy on preventive nursing performance for osteoporosis. Methods: The participants of this study were 150 nurses working in 4 general hospitals. The data were collected during October 2019 using written questionnaires. General characteristics, osteoporosis knowledge, health behavior self-efficacy, and preventive nursing performance for osteoporosis were analyzed using means and standard deviation, t-test, ANOVA, Scheffé test, Pearson's correlation and multiple regression analysis. Results: As a result of multiple regression analysis, the factors affecting preventive nursing performance included osteoporosis prevention education (β=.16, p=.034) and health behavior self-efficacy (β=.51, p<.001). The explanatory power of the model was 31.5%(F=10.94, p<.001). Conclusion: It was found that the experiences of osteoporosis prevention education and health behavior self-efficacy influenced preventive nursing performance for osteoporosis.

Data Processing Method of Radar Processor Unit Test Equipment (레이다처리장치 시험장비의 데이터 처리방안)

  • Lee, Mincheol;Kim, Yong-min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.767-775
    • /
    • 2018
  • To develop and check a Radar Processor Unit, checking the function and performance of the requirement is very important factor in developing Radar. General methods for verifying the Radar is simulation test, environment linkage test and field operation test, firstly, in case of requirement analysis phase, verify Radar algorithm and design by using mathematical method based simulation test method, and secondly, in case of unit test and integrated test phase, Test Equipment is set to simulate radar environment in the lab to verify radar function and performance. Lastly, field operation test phase is carried out to confirm the function and performance after it is mounted on the actual equipment. To successfully develop Radar Processor Unit, using the method of field operation test method after sufficient test cases are tested in radar environmental interlocking method in order to save cost and testing period and because of this reason, development of the Radar Processor Unit Test Equipment is becoming very important factor. In this paper, we introduce the concept of test equipment development and important factors in test equipment, which are target simulation, data processing and device interlocking.

The Effect of Nursing performance, Job stress and Resilience on Nursing Performance of Nurses in General Hospital (종합병원 간호사의 감정노동, 직무스트레스 및 회복탄력성이 간호업무성과에 미치는 영향요인)

  • Jeong, Yun-Ja;Cho, In-Sook
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.613-624
    • /
    • 2020
  • This study is a descriptive research to grasp the effects of nursing performance on emotional labor, job stress and resilience in general hospital nurses. Method: I surveyed them using a structured questionnaire for collecting data from Aug. 20, 2019 to Sep. 2, 2019. The collected data were analyzed by the frequency, the percentage, t-test, ANOVA, Scheffe's Test, Pearson's Correlation Coefficient, and Multiple Regression Analysis. Results: The factors affecting nursing performance of the subjects were resilience (β=0.58, p<.001), and current position is head nurse (β=0.21, p<.01), the number of working years at current working place (β=0.18, p<.05). The F statistics for the fit of the estimated regression model was very significant as 30.901(p<.001) and the explanatory power was 42.4%. Conclusion: The results of this study showed that resilience was the most influential factor to nursing performance of general hospital nurses, and the number of working years at current working place was the most influential factor to the performance of head nurses. Therefore, it is necessary to develop practical programs strengthening resilience of nurses for the improvement of nursing performance and to apply strategies on development.

Conditional Signed-Rank Test for the Tree Alternatives in the Randomized Block Design

  • Yang, Wan-Youn
    • Communications for Statistical Applications and Methods
    • /
    • v.6 no.1
    • /
    • pp.159-168
    • /
    • 1999
  • We introduce a new conditional signed-rank test for the tree alternatives comparing several treatments with a control in the randomized block design. We demonstrate its performance by comparing with 3 classes of signed-rank tests proposed by Park et al.(1991) in some general situations. In most cases the proposed procedure is simpler to compute and has better power than others.

  • PDF

A simple method of stiffness matrix formulation based on single element test

  • Mau, S.T.
    • Structural Engineering and Mechanics
    • /
    • v.7 no.2
    • /
    • pp.203-216
    • /
    • 1999
  • A previously proposed finite element formulation method is refined and modified to generate a new type of elements. The method is based on selecting a set of general solution modes for element formulation. The constant strain modes and higher order modes are selected and the formulation method is designed to ensure that the element will pass the basic single element test, which in turn ensures the passage of the basic patch test. If the element is to pass the higher order patch test also, the element stiffness matrix is in general asymmetric. The element stiffness matrix depends only on a nodal displacement matrix and a nodal force matrix. A symmetric stiffness matrix can be obtained by either modifying the nodal displacement matrix or the nodal force matrix. It is shown that both modifications lead to the same new element, which is demonstrated through numerical examples to be more robust than an assumed stress hybrid element in plane stress application. The method of formulation can also be used to arrive at the conforming displacement and hybrid stress formulations. The convergence of the latter two is explained from the point of view of the proposed method.

Durability Test for the Expansion Joint of High-Speed Railway Bridge (고속철도 교량 신축이음장치의 내구성 실험)

  • 김병석;곽종원;신호상;김영진;박성용;장익순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.894-899
    • /
    • 1998
  • To absorb the deformation of live load, thermal gradient, shrinkage and creep in bridge structures and general structures, expansion joint has to be established. Especially expansion joint for high-speed railway bridge has to accomodate the static and dynamic forces and it not only has the durability of itself but also maintain the durability of structure by preventing the leakage of water. The actual used product of expansion joint for high-speed railway bridge is only ones made in France, Germany and Japan. In this study, the development process and test results of developed expansion joint are introduced which has the functional operation and durability enough to apply to high-speed railway bridges, roadway bridges and general structures. The tests consist of fatigue-durability test of 3 million times by high-speed rail load, leakage test and jack-up test for verifying the possibility of exchanging it. The performance of developed expansion joint satisfy the specification of Korea High Speed Rail Construction authority.

  • PDF

Performance Test and Analysis of Master-Slave Based PLC Modem in General Building (일반 환경에서 마스터-슬레이브 기반 전력선 통신 모뎀의 성능 시험 및 분석)

  • Hwang Min-Tae;Ha Hyun-Seok;Lee Jae-Jo
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.5
    • /
    • pp.660-669
    • /
    • 2005
  • In this paper 10Mbps master-slave based PLC modems are tested for measuring and analyzing both network and application level performances in the general buildings. The devices under test consist of one master PLC modem and three slave modems. The selected parameters for inspecting the performances are throughput, latency and frame loss rate from the RFC 2544, and one-to-many and many-to-one throughput from the RFC 2285. The results of the performance test show that the PLC modems have Performed better in data transmission when the frame size is increased and the transmission speed is decreased. It is expected that these results will be useful to analyze the effect of noise sources when compared to the performance test under the noiseless environments.

  • PDF

Effect of Nurses' Mentoring Function and Organizational Citizen Behavior on Nursing Performance (간호사의 멘토링 기능과 조직시민행동이 간호업무성과에 미치는 영향)

  • Park, Kyung-Hee;Han, Jeong Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.179-187
    • /
    • 2016
  • This study was conducted to identify the factors that affect the nursing performance. These factors are general characteristics, mentoring function and organizational citizenship behavior. A survey was conducted on 163 nurses working for general hospitals in South Korea from December 2 - 30, 2015. The data was analyzed using the SPSS WIN 21.0 program to analyze the descriptive statistics, independent T-test, ANOVA, Scheffe test, Pearson's correlation, and multiple regression. The factors affecting the subject's nursing performance were altruism (${\beta}=.46$, p<.001), courtesy (${\beta}=.12$, p=.047), belonging to the sub areas of the organizational citizenship behaviors, role modeling function (${\beta}=.31$, p=.001), career develop functions (${\beta}=-.22$, p=.018), belonging to the sub areas of the mentoring function, and position (${\beta}=.24$, p<.001). The results of this study are expected to provide basic data to improve the nursing performance.