• 제목/요약/키워드: Gel

검색결과 10,387건 처리시간 0.032초

EDLC용 폴리머 겔 전해질 (Polymer Gel Electrolytes for EDLCs)

  • 정세일;정현철;강안수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2003년도 추계학술대회
    • /
    • pp.351-357
    • /
    • 2003
  • The optimum polymer gel electrolyte composition ratio was 23 : 66 : 11 wt% of P(VdF-co-HFP) : PVP =20 : 3), (PC: EC =44 : 22) and TEABF$_4$. And the optimal thickness of polymer gel electrolyte was 50 ${\mu}{\textrm}{m}$. The electrochemical characteristics result of unit cell were 31.41 Fig of specific capacitance, and 3.21$\times$10$^{-3}$ S/cm of ion conductivity. Ion conductivity of polymer gel electrolytes decreased according to added PVP through impedance analysis, and it was higher in 7 wt%, but electrochemical characteristics of unit cell were better in 3 wt% PVP. And for excellent ion conductivity of polymer gel electrolytes, the use of a thin layer electrolyte(20 $\mu\textrm{m}$) was an effective method, but with unit cell application, the best thickness was 50 $\mu\textrm{m}$. Unit cell showed higher capacitance and more stable electrochemical performance when hot pressed between polymer gel electrolyte and electrode. This results from enhancement of the physical contact between the electrode and the polymer gel electrolyte and good accessibility of the liquid electrolyte to the electrode surface.

  • PDF

Study of the Application of Gel Electrolyte in the Reference Electrode of $Cu/CuSO_4$

  • Lin, Cunguo;Xu, Likun;Liu, Yang
    • Corrosion Science and Technology
    • /
    • 제7권3호
    • /
    • pp.179-181
    • /
    • 2008
  • With nano-$SiO_2$ and sulphate acid, a kind of colloid electrolyte is synthesized by sol-gel method. It is placed outside the reference electrode as a layer of gel electrolyte so as to decrease the leaching of $Cu^{2+}$ and increase the life of the reference electrode. The performance of the gel electrode in simulating soil solution is measured as follows: the potential of the electrodes ranging from 60 mV to 80 mV (vs. SCE) with potential variation no more than $\pm10mV$, enough resistance to polarization. The $Cu^{2+}$ effusion rate of the reference electrode without gel electrolyte is 3 times that with colloid electrolyte, which means that gel electrolyte can extend the life of the reference electrode significantly.

Investigation of Dose Distribution in Mixed Neutron-Gamma Field of Boron Neutron Capture Therapy using N-Isopropylacrylamide Gel

  • Bavarnegin, Elham;Khalafi, Hossein;Sadremomtaz, Alireza;Kasesaz, Yaser;Khajeali, Azim
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.189-195
    • /
    • 2017
  • Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM) polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT). In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the $R_2$ maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

Gradient 2-D PAGE를 이용한 양수 프로테옴 분석 (Proteome Analysis of Amniotic Fluid by gradient 2-D PAGI)

  • 이은희;김재찬;변상요
    • KSBB Journal
    • /
    • 제18권1호
    • /
    • pp.35-38
    • /
    • 2003
  • 양수 내에 존재하는 총 단백질을 이차원 전기영동을 이용하여 분리 분석하였고, gradient gel을 이용하여 양수 내에 소량으로 존재하는 미세 단백질까지 분리하였다. 양수 내에는 고농도로 존재하는 단백질이 있는데 이것이 serum albumin precursor임을 확인하였고, 8-18% gradient gel의 이용으로 분해능(resolution)이 향상되어 미세 단백질을 분리 분석할 수 있었다. 이차원 전기영동 후 MALDI-TOF를 이용하여 단백질을 identification하여 기존의 양수 protein database에 존재하는 단백질을 확인하였고, 존재하지 않는 새로운 단백질을 분리 분석하였다.

Large and Small Deformation Studies of Ohmic and Water-Bath Heated Surimi Gel by TPA and Creep Test

  • Choi, Won-Seok;Lee, Cherl-Ho
    • Food Science and Biotechnology
    • /
    • 제15권3호
    • /
    • pp.409-412
    • /
    • 2006
  • Interrelationship between results of large deformation (texture profile analysis, TPA) test and small deformation (creep) test on ohmic heated surimi gel, water-bath heated surimi gel, and commercial fish gel products (kamabokos) was examined. Creep test revealed ohmic heated gels have higher elastic modulus and viscosity values than water-bath heated ones, with differences of elastic modulus and viscosity between ohmic and water-bath heated gels being 18 and 28.5%, respectively. These differences were reflected in the higher hardness, cohesiveness, and chewiness values of ohmic heated gels in TPA. In TPA test, the differences of hardness and chewiness between ohmic heated gel and water-bath heated gel were 29.3 and 38.7%, respectively. It was concluded that with proper experimental design, the small deformation creep test which gives molecular level deformation data can be related to the large deformation TPA test indicating the sensory textural properties.

Chemical Structure Effect of Diisocyanate on the Coating Performance of Polyurethane-based Gel-coats

  • Park, Jin Hwan;Baek, Seung-Suk;Kim, Oh Young;Hong, Seheum;Park, Dong Hyup;Hwang, Seok-Ho
    • Elastomers and Composites
    • /
    • 제54권1호
    • /
    • pp.30-34
    • /
    • 2019
  • Four different diisocyanates (IPDI; isophorone diisocyanate, HDI; hexamethylene diisocyanate, HMDI; dicyclohexylmethane-4,4'-diisocyanate, and XDI; m-xylylene diisocyanate) were used to prepare polyurethane gel-coats, and the weatherabilities, physical properties, and surface characteristics of the gel-coats were investigated with respect to the chemical structure of the diisocyanates. The weathering test results indicated that all of the diisocyanates used in this study were suitable for use in the preparation of the polyurethane gel-coat. However, the set-to-touch times and physical properties of the polyurethane gel-coat indicated that the cycloaliphatic diisocyanate (IPDI and HMDI) were ideal for the preparation of polyurethane gel-coats.

쉬폰 케이크의 품질 특성에 미치는 알로에의 영향 (Effects of Aloe (Aloe vera Linne) on the Quality Attributes of Chiffon Cake)

  • 김혜영;신두호;정용남
    • 한국식품저장유통학회지
    • /
    • 제16권6호
    • /
    • pp.900-907
    • /
    • 2009
  • 기능성 소재로서 알로에를 활용하여, 쉬폰 케이크를 개발하기 위하여 알로에 겔을 여러 농도로 첨가하여 쉬폰케이크를 제조하였다. 알로에 겔을 박력분 대비 20%, 40% 그리고 60%, 첨가하여 알로에 쉬폰 케이크를 제조한 후, 알로에 쉬폰 케이크의 품질 특성을 조사하였다. 중량은 대조군과 알로에 겔 첨가군간 유의적인 차이를 보이지 않았다. 높이는 알로에 겔 첨가군이 대조군에 비해 유의적으로 높이가 낮게 나타났다. 굽기 손실률은 알로에 겔 첨가량이 증가됨에 따라 감소하였고, 60% 알로에 겔 첨가군의 굽기 손실률이 유의적으로 가장 낮았다. 수분함량은 알로에 겔첨가군이 대조군에 비해 유의적으로 높았으며, 60% 알로에 겔 첨가군의 수분 함량이 가장 높았다. 기공의 크기를 관찰한 결과 60% 알로에 겔 첨가군의 기공이 가장 작았다. 그리고 crumb의 색은 알로에 겔의 첨가량이 증가함에 따라 흰색이 강해졌다. 대조군의 L(Lightness) 값은 알로에 겔 첨가군 보다 낮았다. a value(Redness)는 알로에 겔 함량이 증가함에 따라 함께 증가하였다. 40% 알로에 겔이 첨가된 케이크의 b value(Yellowness)만이 대조군보다 유의적으로 높았다. 다른 군의 b value는 대조군과 차이를 보이지 않았다. 모든 군의 경도는 대조군보다 유의적으로 낮았다. 대조군의 부착성이 다른 군에 비해 가장 낮았다. 탄력성은 군간 유의적인 차이를 나타내지 않았다. 응집성은 알로에 겔 40% 첨가군이 대조군과 알로에 겔 20% 첨가군에 비해 유의적으로 낮았다. 대조군의 검성과 씹힘성은 알로에 첨가군에 비하여 유의적으로 높았다. 케익의 노란색은 알로에 겔 60% 첨가군에서 가장 낮았다. 또한, 알로에 겔을 첨가한 경우 기공의 크기가 감소하였다. 외관의 전체적인 선호도는 군간 유의적인 차이를 보이지 않았다. 비록 알로에 냄새는 알로에 겔 처리군과 대조군 사이에 유의적인 차이를 보이지 않았으나, 냄새 선호도는 알로에 겔 60% 첨가군이 다른군에 비해 유의적으로 낮았다. 맛 선호도, 촉촉함 그리고 질감 선호도는 군간에 유의적인 차이를 나타내지 않았다. 알로에 겔 40% 와 60% 첨가군이 유의적으로 높은 조밀도를 나타내었다. 전체적인 선호도는 60% 알로에 겔 첨가군이 다른 군에 비해 유의적으로 낮았다. 결론적으로, 알로에 겔을 쉬폰 케이크에 첨가하여 제품 제시 밀가루 대비 40% 이하로 첨가하는 것이 바람직함을 알 수 있었다.

Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가 (Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy)

  • 이훈희;김찬규;송관수;방문균;강동윤;신동호;이두현
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.191-199
    • /
    • 2018
  • 목 적 : 본 연구는 colloid gel(slime)을 자체 제작하여, 방사선치료에서 불규칙한 환자 체표면에 대한 보상체로 적용하기 위하여 유용성을 평가하고자 한다. 대상 및 방법 : 본 연구를 위하여 치료에 적합한 colloid gel을 자체적으로 제작하였고, 방사선 치료 적용 가능성 평가를 위해 네 가지 실험을 하였다. 치료 장비 및 CT 장비로는 Trilogy(Varian)와 CT(SOMATOM, Siemens)를 이용하였다. 첫 번째로 colloid gel의 조성에 따른 균질도를 EBT3 Film(RIT)을 이용하여 측정하였다. 두 번째는 colloid gel의 Hounsfield Unit(HU)값을 CRIS phantom과 Eclipse RTP(Eclipse 13.1, Varian) 및 CT 촬영을 이용하여 선량 측정 및 확인을 하였다. 세 번째로 colloid gel의 치료 기간 내 변형 및 변질을 검사하기 위하여 ion chamber(PTW-30013, PTW)를 이용하여 매일 3회씩, 2주간 측정하였다. 네 번째 실험은 자체 제작한 아크릴 팬텀을 이용하여 실제 치료와 유사한 환경에서 bolus, rice, colloid gel을 이용한 치료계획 및 측정된 선량 분포 비교하였고, 추가적으로 dose profile도 확인하였다. 결 과 : 첫 번째 실험에서 조성된 colloid gel case 1, 2, 3의 밀도는 각각 평균 $1.02g/cm^3$, $0.99g/cm^3$, $0.96g/cm^3$이었으며, 6 MV 및 9 MeV에서 측정된 균질도를 판단하였을 때 case 1이 표준편차 1.55, 1.98로 다른 case들에 비해 더 균질한 것으로 확인되었다. 두 번째 실험에서는 HU값은 case 1, 2, 3 평균 15 HU로 확인되었으며, 치료계획과 측정된 선량을 비교하였을 때 9, 12 MeV 모든 측정 위치에서 1 % 이내 차이를 보였으며, 6 MV는 두 측정 위치에서 -1.53 %, -1.56 % 차이로 전체 2 % 내의 오차를 보였다. 세 번째 실험에서는 2주 동안 측정하였을 때 colloid gel의 선량변화가 1 % 내외로 측정되었다. 네 번째 실험에서는 치료계획과 EBT3 film으로 측정된 결과를 비교하였을 때 6 MV에서는 bolus, rice 모두 비슷한 선량 차이를 보였으며, 9 MeV에서는 photon과 달리 colloid gel이 bolus, rice와 비교하여 선량 차이가 적게 나는 것을 확인하였다. Dose profile 면에서도 colloid gel이 bolus, rice보다 균일한 dose 분포를 보였다. 결 론 : 본 연구에서 방사선치료를 위해 제작된 colloid gel의 밀도는 $1.02g/cm^3$로 물의 밀도와 비슷하며, 방사선치료 과정 동안 변질 및 변형이 확인되지 않았다. Colloid gel 제작 시 밀도에 유의를 해야 하지만, bolus, rice보다 환자의 체표면에 대한 충분한 보상을 통해 선량을 균일하게 전달할 수 있고, 저가에 제작을 할 수 있다는 점에서도 충분한 장점이 있다. 앞으로 임상적용을 위한 추가적인 실험 및 연구를 통해 방사선치료에 적용할 수 있을 것으로 사료된다.

  • PDF

수산화알루미늄.겔의 X선회절상과 제산도 (X-Ray Diffraction Patterns and Acid Consuming Capacity of Aluminum Hydroxide Gel.)

  • 조문혜
    • 약학회지
    • /
    • 제8권2호
    • /
    • pp.37-44
    • /
    • 1964
  • The relationships involving acid-consuming capacity and X-ray powder diffraction patterns of aluminum hydroxide gel were studied. The aging of antacid efficacy of aluminum hydroxide gel has also been characterized by using X-ray powder diffraction. The acid-consuming capacity decreased with progress of crystallization from amorphous alumino gel, and it was found that aged product at 80.deg. C had crystal structure of bohmite (.alpha.-Al.sub 2/O$_{2}$(OH)$_{2}$). It was also noted that the rate of aging decreased with decreasing pH of aluminum hydroxide gel.

  • PDF

Sodium dodecyl sulfate polyacrylamide gel 전기영동 결과의 경제적인 평가 방법 (A rapid method for sodium dodecyl sulfate polyacrylamide gel electrophoresis evaluation)

  • ;;정영섭
    • 미생물학회지
    • /
    • 제27권4호
    • /
    • pp.436-438
    • /
    • 1989
  • We propose a method for rapid evaluation and permanent record of sodium dodecyl sulfate polyacrylamide gel electrophoretic runs. This method is based on the photocopy process, rather than on photography and requires no extensive or expensive investment. Comparison of a print obtained through this method and a 35mm photography indicated, on a balanced gel, equal sensitivity.

  • PDF