Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study

  • Youngjin Lee;Chanrok Park
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4652-4659
    • /
    • 2022
  • Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.

다양한 두께의 부가 여과판을 적용한 X-선 영상에서의 Total Variation 알고리즘 적용 : GATE 시뮬레이션 연구 (Application of Total Variation Algorithm in X-ray Phantom Image with Various Added Filter Thickness : GATE Simulation Study)

  • 박태일;장수종;이영진
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.773-778
    • /
    • 2019
  • X-선을 이용한 영상은 진단에 필수적인 요소지만 영상에서의 noise발생이 불가피하다. 이를 보완하기 위해 환자의 피폭선량은 낮추면서 영상의 질은 높여주는 total variation (TV) 알고리즘이 제시되었다. 본 연구의 목적은 시뮬레이션을 통해 부가 여과판의 두께에 따라 방사선 영상 촬영 시 영상의 화질에 미치는 영향을 확인하고, TV 알고리즘의 유용성을 평가하는 것이다. 부가 여과판의 두께변화에 따른 각 알고리즘 적용 시 Geant4 Application for Tomographic Emission (GATE) 시뮬레이션 영상을 이용하여 Polymethylmethacrylate(PMMA) 팬텀의 실제 크기, 모양과 재질을 동일하게 하고 대조도 대 잡음비 (contrast to noise ratio, CNR)과 변동계수 (coefficient of variation, COV)값을 비교하였으며 그 결과 TV 알고리즘 적용 시 CNR 값이 가장 높고 COV 값이 가장 낮다는 것을 확인할 수 있었다. 또한, 모든 알고리즘에서 0 mmAl을 사용할 경우 가장 우수한 CNR과 COV값을 얻을 수 있었다.

GAGG 섬광체 물질을 적용한 감마카메라 영상의 유용성 평가: 몬테카를로 시뮬레이션 연구 (Usefulness of New GAGG Scintillation Detector for Gamma Camera : A Monte Carlo Simulation Study)

  • 김정수;박찬록
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.511-515
    • /
    • 2020
  • 본 연구의 목적은, 새롭게 제안된 Gadolinium Aluminum Gallium Garnet (GAGG) 기반 감마카메라를 Geant 4 Application for Tomographic Emission (GATE) 모사 도구(simulation tool)를 통해 설계하고, National Electrical Manufacturers Association International Electrotechnical Commission에서 제작한 몸통 팬텀 모사를 통해 기존의 사용되고 있는 NaI(Tl) 섬광체 기반 감마카메라 시스템과 99mTc 방사성동위원소를 이용해 900 초 동안 영상을 획득했다. Contrast to noise ratio (CNR) 과 Coefficient of variation (COV) 의 정량분석 방법을 사용해 해당 관심영역에 대해 영상을 평가하였다. CNR 과 COV 결과에 따라, 결과적으로 GAGG 기반 감마 영상의 질이 우수함을 확인하였다.

인체모사 팬텀 기반 Fast non local means 노이즈 제거 알고리즘의 필터링 인자 변화에 따른 영상 최적화: 시뮬레이션 연구 (Image Optimization of Fast Non Local Means Noise Reduction Algorithm using Various Filtering Factors with Human Anthropomorphic Phantom : A Simulation Study)

  • 최동혁;김진홍;최종호;강성현;이영진
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.453-458
    • /
    • 2019
  • 본 연구에서는 Geant4 application for tomographic emission (GATE) 시뮬레이션 프로그램을 통해 설계 된 male adult mesh (MASH) 팬텀의 영상을 획득한 후 다양한 필터링 인자가 설정된 FNLM 노이즈 제거 알고리즘을 적용함으로써 그에 따른 영상 특성의 경향성을 알아보고자 한다. 이를 위해 GATE 시뮬레이션 프로그램을 통해 인체를 모사할 수 있는 MASH 팬텀을 설계하였다. 또한, 설계된 MASH 팬텀을 기반으로 MATLAB 프로그램을 통해 복부영상을 획득한 후 0.005의 $\sigma$ 값을 갖는 Gaussian noise를 추가하여 열화영상을 모델링하였다. 모델링 된 열화영상으로부터 제안하는 FNLM 노이즈 제거 알고리즘의 필터링 인자를 각각 0.005, 0.01, 0.05, 0.1, 0.5, 1.0 으로 설정하여 적용하였으며, 정량적 평가를 위해 FNLM 노이즈 제거 알고리즘이 적용된 영상들로부터 각각의 coefficient of variation (COV), signal to noise ratio (SNR) 그리고 contrast to noise ratio (CNR)을 측정하였다. 결과적으로, 0.05의 필터링 인자가 적용된 영상에서 가장 개선된 COV, SNR 그리고 CNR 값을 보였다. 특히, COV는 설정된 필터링 인자가 증가함에 따라 감소하였으며, 0.05 값 이후부터 거의 일정한 값을 나타내었다. 또한, SNR 및 CNR의 경우 필터링 인자가 증가함에 따라 증가하였으며, 0.05 값 이후부터 감소하는 경향을 보였다. 결론적으로, 열화 영상으로부터 FNLM 노이즈 제거 알고리즘 적용 시 적합한 필터링 인자를 설정해야 함이 증명되었다.

다양한 팬텀 모양 및 재질에 따른 전산화단층촬영장치 선량 평가 (Estimation of Computed Tomography Dose in Various Phantom Shapes and Compositions)

  • 이창래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.13-18
    • /
    • 2017
  • 본 논문은 GATE (geant4 application for tomographic emission) 시뮬레이션을 이용하여 다양한 모양과 재질의 팬텀에서 CTDI (computed tomography dose index)를 평가하였다. GATE 시뮬레이션은 실린더 기둥, 타원 기둥과 육각 기둥 형태와 물, PMMA (polymethyl methacrylate), polyethylene 그리고 polyoxymethylene 재질의 다양한 지름(1 ~ 50 cm)의 팬텀을 모사하여 $CTD_{I100center}$ 값을 비교하였다. 120 kV, 200 mAs에서 실린더 기둥, 타원 기둥과 육각 기둥의 $CTDI_{100center}$ 값은 각각 11.1, 13.4 그리고 12.2 mGy이었다. 이 결과는 동일 볼륨이지만 팬텀의 형태에 따라 $CTDI_{100center}$ 값의 차이가 있음을 알 수 있다. 그리고 물, PMMA 그리고 polyoxymethylene 팬텀의 $CTDI_{100center}$ 값을 비교했을 때 물질의 밀도가 높을수록 상대적으로 $CTDI_{100center}$ 값이 낮게 측정되었다. 하지만 polyethylene의 경우 지름이 15 cm ($CTDI_{100center}$ : 35.0 mGy) 이 상에서는 PMMA 보다 $CTDI_{100center}$ 값이 증가하였다. 그리고 30 cm ($CTDI_{100center}$ : 17.7 mGy) 이 상의 지름에서는 물 보다 더 높은 $CTDI_{100center}$ 값을 보였다. 본 실험을 통해 팬텀의 재질 및 모양에 따른 $CTDI_{100center}$ 값을 GATE 시뮬레이션을 이용하여 평가하였다. CT 선량 평가시 다양한 재질 및 인체에 가까운 모양의 팬텀을 사용함으로써 좀 더 정확한 환자선량을 평가할 수 있을 것이다.

Study on the PET image quality according to various scintillation detectors based on the Monte Carlo simulation

  • Eunsoo Kim;Chanrok Park
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.129-132
    • /
    • 2023
  • Purpose: Positron emisson tomography (PET) is a crucial medical imaging scanner for the detection of cancer lesions. In order to maintain the improved image quality, it is crucial to apply detectors of superior performance. Therefore, the purpose of this study was to compare PET image quality using Monte Carlo simulation based on the detector materials of BGO, LSO, and LuAP. Materials and Methods: The Geant4 Application for Tomographic Emission (GATE) was used to design the PET detector. Scintillations with BGO, LSO and LuAP were modelled, with a size of 3.95 × 5.3 mm2 (width × height) and 25.0 mm (thickness). The PET detector consisted of 34 blocks per ring and a total of 4 rings. A line source of 1 MBq was modelled and acquired with a radius of 1 mm and length of 20 mm for 20 seconds. The acquired image was reconstructed maximum likelihood expectation maximization with 2 iteration and 10 subsets. The count comparison was carried out. Results and Discussion: The highest true, random, and scatter counts were obtained from the BGO scintillation detector compared to LSO and LuAP. Conclusion: The BGO scintillation detector material indicated excellent performance in terms of detection of gamma rays from emitted PET phantom.

GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사 (Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6)

  • 안수정;이창래;백철하
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.571-575
    • /
    • 2016
  • 본 연구에서는 몬테칼로 전산모사 코드인 GATE6 (Geant4 Application for Tomographic Emission ver.6)를 사용하여 의료용 선형 가속기인 Varian사의 Clinac 21EX를 모사하고, 6 MV 광자선의 선량 특성을 평가하였다. 몬테칼로 방법은 방사선 치료시 환자 내의 선량분포를 계산하는 가장 정확한 방법으로 널리 이용되고 있다. 몬테칼로 기반의 코드를 이용하여 선형가속기의 조사 헤드부를 통과하는 입자의 흐름을 모사하는 것은 조사선량을 정량화 하는데 필요한 입자들의 에너지, 공간 분포와 같은 임상적인 빔의 특성을 결정하기 위한 실용적인 방법이다. 본 연구에서 모사한 선형가속기의 조사 헤드부는 빔 경로에 위치한 타겟, 일차 콜리메이터, 선속 평탄 필터, 이온전리함, 이차 콜리메이터로 구성된다. 모사된 선형가속기를 이용하여 선원-표면간 거리 100 cm, 조사야 $10{\times}10cm^2$ 조건에서 물팬텀 내의 광자선 에너지 스펙트럼(energy spectrum), 심부선량백분율(percentage depth dose), 선량프로파일(dose profiles)을 측정하였으며, 이 결과값을 실험 측정값과 비교하여 정확성을 검증하였다. 본 연구에서는 모사를 통한 결과값과 실험값이 매우 일치함을 보였으며, 이를 통해 GATE6 전산모사 코드는 방사선치료에 사용되는 광자선을 모사하기에 효과적임을 입증하였다.

Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1947-1954
    • /
    • 2021
  • In the nuclear medicine imaging, quality control (QC) process using quadrant bar phantom is fundamental aspect of evaluating the spatial resolution. In addition, QC process of gamma camera is performed by daily or weekly. Recently, Monte Carlo simulation using the Geant4 application for tomographic emission (GATE) is widely applied in the pre-clinical nuclear medicine field for modeling gamma cameras with pixelated cadmium telluride (CdTe) semiconductor detector. In this study, we modeled a pixelated CdTe semiconductor detector and quadrant bar phantom (0.5, 1.0, 1.5, and 2.0 mm bar thicknesses) using the GATE tool. Similarity analysis based on correlation coefficients and peak signal-to-noise ratios was performed to compare image qualities for various source to collimator distances (0, 2, 4, 6, and 8 cm) and collimator lengths (0.2, 0.4, 0.6, 0.8, and 1.0 cm). To this end, we selected reference images based on collimator length and source to collimator distance settings. The results demonstrate that as the collimator length increases and the source to collimator distance decreases, the similarity to reference images improves. Therefore, our simulation results represent valuable information for the modeling of CdTe-based semiconductor gamma imaging systems and QC phantoms in the field of nuclear medicine.

엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구 (Image Quality Improvement through Energy Spectrum Change for X-ray)

  • 김구;김능균;이승재
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.71-78
    • /
    • 2021
  • 엑스선 영상을 획득하는 경우에 연속 엑스선을 사용할 경우, 다양한 엑스선 에너지로 인해 같은 물질이라도 두께에 따라 영상에서 정확하게 표현되지 않을 수 있다. 이를 해결하기 위해 엑스선 에너지스펙트럼을 변경하여 영상의 질을 향상 시킬 수 있도록 하였다. SPEKTR v3.0을 사용하여 부가 필터를 추가한 엑스선 에너지스펙트럼과 고유 필터만을 사용한 일반 엑스선 에너지스펙트럼을 획득하였다. 획득한 엑스선 에너지스펙트럼을 Geant4 Application for Tomographic Emission(GATE)의 방사선원으로 사용하여 시뮬레이션을 수행하였다. GATE 데이터를 사용하여 부가 필터가 사용된 엑스선 영상과 부가 필터를 사용하지 않은 엑스선 영상을 재구성한 영상을 74 keV의 단일 에너지 영상을 통해서 비교 분석하였다. 부가 필터를 사용하지 않은 엑스선 에너지스펙트럼을 사용한 경우 같은 물질이라도 두께에 따라 투과한 엑스선의 양이 물질 두께에 따라 감소되는 양과는 상이한 양상을 보인 반면, 부가 필터를 사용한 경우 두께에 따라 투과된 엑스선의 양이 물질 두께에 따라 감소되는 양과 유사한 결과가 나왔다. 즉, 감소되는 선량이 단일 에너지를 사용했을 때와 비슷한 결과가 나왔다. 부가 필터를 사용하여 엑스선 에너지스펙트럼을 변경하여 엑스선 영상을 획득할 경우 엑스선의 투과에 대한 보다 정확한 결과의 값을 획득할 수 있다. 영상의학검사에서 부가 필터의 적절한 사용이 영상의 질을 높이는데 크게 작용한다는 것을 확인하였다.

GATE 시뮬레이션 프로그램을 이용한 I-131의 영상 특성의 타당성에 관한 연구 (Validation Study for Image Performance of I-131 Using GATE Simulation Program)

  • 백철하;김대호;이용구;이영진
    • 전자공학회논문지
    • /
    • 제54권5호
    • /
    • pp.133-137
    • /
    • 2017
  • 본 연구의 목적은 GATE (Geant4 Application for Tomographic Emission) Simulation을 사용하여 치료용 방사성동위원소인 I-131의 감마카메라/SPECT 영상을 획득하여, 실제 기기의 실험결과와 그 특성을 비교 및 분석 하여 GATE simulation의 정확성을 획득하는 것이다. 더 나아가 GATE simulation을 이용한 치료용 방사성동위원소를 위한 감마카메라/SPECT 영상 정량화 기반기술 연구가 가능함을 입증하고자 한다. 본 연구에서 Simulation상에서 구성한 SPECT System은 Stream-R Forte version 1.2 (Philips Medical System, Best and Heerlen, Netherlands)의 설계변수를 참고로 하였다. 감마카메라/SPECT 시스템에서의 I-131 영상특성을 이해하기 위하여 실제 Forte 시스템을 이용하여 산란물질을 사용하였을 때와 사용하지 않았을 때 에너지 스펙트럼 및 선 선원에 대한 선 응답함수 (Line Spread Function, LSF)와 반치폭 (Full Width at Half Maximum, FWHM)을 측정하였다. 또한 실제 실험과의 비교를 위하여 GATE simulation에서 구성한 시스템에서도 동일한 실험 조건 및 변수에 대하여 에너지 스펙트럼 및 선 선원에 대한 LSF 및 FWHM을 측정하였다. 그 결과 산란물질을 사용하지 않았을 때의 에너지 스펙트럼의 경우 실제 실험과 Simulation 모두 364 keV의 위치에서 에너지 피크를 나타내어 동일한 경향의 결과를 보였다. FWHM은 실제 실험과 Simulation 모두에서 선원과 검출기간의 거리가 증가함에 따라 그 크기가 증가하는 경향을 보였으며 오차율은 3.8%로 나타났다. 산란물질을 사용하였을 때의 에너지 스펙트럼 역시 실제 실험과 Simulation 경우 모두에서 비슷한 경향을 나타내었다. 결론적으로, GATE simulation은 치료용 방사성 동위원소에 대해서도 실제 기기의 특성 및 방사성 동위원소의 특징을 모두 반영하고 있으며 이를 이용하여 감마카메라/SPECT에서의 치료용 방사성 동위원소의 정량화에 대한 다양한 연구가 가능 할 것이라고 사료된다.