• Title/Summary/Keyword: GeTe

Search Result 238, Processing Time 0.025 seconds

Diagnosis of Graft-Versus-Host Disease after Bone Marrow Transplantation by in vivo Proton MR Spectroscopy of the Liver: Correlation with Pathologic Results

  • Cho, Soon-Gu;Lee, Moon-Hee;Suh, Chang-Hae
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.135-135
    • /
    • 2001
  • Purpose: To know the differences of the proton MR spectroscopic features of the liver between th patients with graft-versus-host disease (GVHD) and without GVHD (non-GVHD) after to marrow transplantation (BMT), and to evaluate the possibility to discriminate GVHD fro non-GVHD by analysis of the in vivo proton MR spectra. Method: We evaluated the in vivo proton MR spectra from the livers of 37 patients wh underwent BMT. Our series included 14 cases with GVHD and 23 without GVHD in the liver. Nineteen men and 18 women were included in our series. All cases of GVHD and 2 o non-GVHD were confirmed by liver biopsy and remaining of non-GVHD by evaluation clinical follow up. Proton MR spectroscopy (1H-MRS) was performed at 1.5T GE Sign Horizon (GE Medical System, Milwaukee, USA) system using localized proton STEAM sequence and body coil in all cases with subjects were located in supine position. N respiratory interruption was required during the spectroscopic signal acquisition. Paramete using in MRS were: TR = over 3000ms, TE = 30ms, number of scans = 128, voxel size = ($2{\times}2{\times}2$)$cm^3$, and one NEX. We evaluated the spectra with an attention to the differences o patterns of the peaks between GVHD and non-GVHD groups. The ratio of peak area of peaks at 1.6-4.1ppm to lipid (0.9-1.6ppm) [P(1.6-4.1ppm)/P(0.9-1.6ppm)] was calculated in GVHD and non-GVHD group, and compared the results between these groups. We als evaluated the sensitivity and specificity for discriminating GVHD from non-GVHD by anal of 1H-MRS.

  • PDF

Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy (경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성)

  • Lim, Jeong-Hwan;Song, Jun-Hyeok;Shin, Kyu-Man;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF

Stack-Structured Phase Change Memory Cell for Multi-State Storage (멀티비트 정보저장을 위한 적층 구조 상변화 메모리에 대한 연구)

  • Lee, Dong-Keun;Kim, Seung-Ju;Ryu, Sang-Ouk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.1
    • /
    • pp.13-17
    • /
    • 2009
  • In PRAM applications, the devices can be made for both binary and multi-state storage. The ability to attain intermediate stages comes either from the fact that some chalcogenide materials can exist in configurations that range from completely amorphous to completely crystalline or from designing device structure such a way that mimics multiple phase chase phenomena in single cell. We have designed stack-structured phase change memory cell which operates as multi-state storage. Amorphous $Ge_xTe_{100-x}$ chalcogenide materials were stacked and a diffusion barrier was chosen for each stack layers. The device is operated by crystallizing each chalcogenide material as sequential manner from the bottom layer to the top layer. The amplitude of current pulse and the duration of pulse width was fixed and number of pulses were controlled to change overall resistance of the phase change memory cell. To optimize operational performance the thickness of each chalcogenide was controlled based on simulation results.

  • PDF

Current Status of Nanostructured Thermoelectric Materials for Mid-High Temperature Applications (나노구조 기반 중·고온용 열전소재 연구 동향)

  • Nam, Woo Hyun;Shin, Weon Ho;Cho, Jung Young;Seo, Won-Seon
    • Ceramist
    • /
    • v.22 no.2
    • /
    • pp.133-145
    • /
    • 2019
  • Thermoelectric energy conversion has attracted much attention because it can convert heat into electric power directly through solid state device and vice versa. Current research is aimed at increasing the thermoelectric figure of merit (ZT ) by improving the power factor and reducing the thermal conductivity. Although there have been significant progresses in increasing ZT of material systems composed of Bi, Te, Ge, Pb, and etc. over the last few decades, their relatively high cost, toxicity, and the scarcity have hindered further development of thermoelectrics to expand practical applications. In this paper, we review the current status of research in the fields of nanostructured thermoelectric materials with eco-friendly and low cost elements, such as skutterudites and oxides, for mid-high temperature applications, highlighting the strategies to improve thermoelectric performance.

Gamma-Ray and Neutrino Emissions from Starburst Galaxies

  • Ha, Ji-Hoon;Ryu, Dongsu;Kang, Hyesung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.37.1-37.1
    • /
    • 2020
  • Cosmic-ray protons (CRp) are efficiently produced at starburst galaxies (SBGs), where the star formation rate (SFR) rate is high. In this talk, we present estimates of gamma-ray and neutrino emissions from nearby SBGs, M82, NGC253, and Arp220. Inside the starburst nucleus (SBN), CRp are accelerated at supernova remnant (SNR) shocks as well as at stellar wind (SW) termination shocks, and their transport is governed by the advection due to starburst-driven wind and diffusion mediated by turbulence. We here model the momentum distributions of SNR and SW-produced CRp with single or a double power-law forms. We also employ two different diffusion models, where CRp are resonantly scattered off large-scale turbulence in SBN or self-excited waves driven by CR streaming instability. We then calculate gamma-ray/neutrino fluxes. The observed gamma-ray fluxes by Fermi-LAT, Veritas, and H.E.S.S are well reproduced with double power-law distribution for SNR-produced CRp and the CRp diffusion by self-excited turbulence. The estimated neutrino fluxes are <~10-3 of the atmospheric neutrino flux in the energy range of Eneutrino <~100 GeV and <~10-1 of the IceCube point source sensitivity in the energy range of Eneutrino >~60 TeV.

  • PDF

Perfusion MR Imaging of the Brain Tumor: Preliminary Report (뇌종야의 관류 자기공명영상: 예비보고)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.119-124
    • /
    • 1997
  • Purpose: To assess the utility of magnetic resonance(MR) cerebral blood volume (CBV) map in the evaluation of brain tumors. Materials and Methods: We performed perfusion MR imaing preoperatively in the consecutive IS patients with intracranial masses(3 meningiomas, 2 glioblastoma multiformes, 3 low grade gliomas, 1 lymphoma, 1 germinoma, 1 neurocytoma, 1 metastasis, 2 abscesses, 1 radionecrosis). The average age of the patients was 42 years (22yr -68yr), composed of 10 males and S females. All MR images were obtained at l.ST imager(Signa, CE Medical Systems, Milwaukee, Wisconsin). The regional CBV map was obtained on the theoretical basis of susceptibility difference induced by first pass circulation of contrast media. (contrast media: IScc of gadopentate dimeglumine, about 2ml/sec by hand, starting at 10 second after first baseline scan). For each patient, a total of 480 images (6 slices, 80 images/slice in 160 sec) were obtained by using gradient echo(CE) single shot echo-planar image(EPI) sequence (TR 2000ms, TE SOms, flip angle $90^{\circ}$, FOV $240{\times}240mm,{\;}matrix{\;}128{\times}128$, slice-thick/gap S/2.S). After data collection, the raw data were transferred to CE workstation and rCBV maps were generated from the numerical integration of ${\Delta}R2^{*} on a voxel by voxel basis, with home made software (${\Delta}R2^{*}=-ln (S/SO)/TE). For easy visual interpretation, relative RCB color coding with reference to the normal white matter was applied and color rCBV maps were obtained. The findings of perfusion MR image were retrospectively correlated with Cd-enhanced images with focus on the degree and extent of perfusion and contrast enhancement. Results: Two cases of glioblastoma multiforme with rim enhancement on Cd-enhanced Tl weighted image showed increased perfusion in the peripheral rim and decreased perfusion in the central necrosis portion. The low grade gliomas appeared as a low perfusion area with poorly defined margin. In 2 cases of brain abscess, the degree of perfusion was similar to that of the normal white matter in the peripheral enhancing rim and was low in the central portion. All meningiomas showed diffuse homogeneous increased perfusion of moderate or high degree. One each of lymphoma and germinoma showed homogenously decreased perfusion with well defined margin. The central neurocytoma showed multifocal increased perfusion areas of moderate or high degree. A few nodules of the multiple metastasis showed increased perfusion of moderate degree. One radionecrosis revealed multiple foci of increased perfusion within the area of decreased perfusion. Conclusion: The rCBV map appears to correlate well with the perfusion state of brain tumor, and may be helpful in discrimination between low grade and high grade gliomas. The further study is needed to clarify the role of perfusion MR image in the evaluation of brain tumor.

  • PDF

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

Biological activities in Aronia melanocarpa depending on drying methods (건조방법에 따른 아로니아의 생리활성)

  • Lee, Seul;Moon, Hey-Kyung;Lee, Su-Won;Moon, Jae-Nam;Kim, Jong-Kuk
    • Food Science and Preservation
    • /
    • v.23 no.7
    • /
    • pp.1018-1025
    • /
    • 2016
  • To investigate biological activities in Aronia melanocarpa various drying methods were employed such as vacuum freeze drying, hot air drying and cold air drying. DPPH radical scavenging activity and ABTS radical scavenging activity of vacuum freeze dried Aronia melanocarpa was higher than hot and cold air dried Aronia melanocarpa. Vacuum freeze drying method showed the greatest contents of total phenol (15.34 g GAE/100 g), flavonoid (3.10 g GE/100 g) and tannin (2.46 g TE/100 g). Total anthocyanin content decreased to 163.52 mg C3G/100 g and 50.15 mg C3G/100 g for hot and cold air drying, respectively. Vacuum freeze-dried method increased the total anthocyanin content (743.09 mg C3G/100 g) when compared with fresh Aronia melanocarpa (163.52 mg C3G/100 g). Total proanthocyanidin content of vacuum freeze dried Aronia melanocarpa has increased to 6.21 g CE/100 g more than eight times compared with fresh Aronia melanocarpa (0.71 g CE/100 g). Chlorogenic acid and neochlorogenic acid content of vacuum freeze dried Aronia melanocarpa were higher than hot air dried and cold air dried Aronia melanocarpa, increasing about three times compared with fresh Aronia melanocarpa. These results suggested that vacuum freeze drying is optimal drying method to enhance biological activities in Aronia melanocarpa.

Quality Characteristics and Antioxidant Activity of Prickly Pear Cactus Cladodes (손바닥 선인장 엽상경의 품질 특성과 항산화 효과)

  • Hwang, Joon-Ho;Yi, Mi-Ran;Kim, Jae-Won;Bu, Hee-Jung;Kang, Chang-Hee;Lim, Sang-Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.3
    • /
    • pp.356-362
    • /
    • 2015
  • Prickly pear cactus cladodes were extracted with hot water and 70% ethanol, followed by fractionation with n-hexane (HF), ethyl acetate (EF), n-butanol (BF), and distilled water. Total phenolics and total flavonoid contents as well as antioxidative and anti-inflammatory activities were then measured. Total phenolic contents were 784, 452, and 220 mg gallic acid equivalents (GAE)/g, whereas total flavonoid contents were 214, 76, and 113 mg quercetin equivalents (QE)/g in EF, BF, and HF, respectively. DPPH and ABTS radical scavenging activities ($IC_{50}$) were 103 and $105{\mu}g/mL$ in EF, 359 and $379{\mu}g/mL$ in BF, and 469 and $605{\mu}g/mL$ in HF, respectively. Oxygen radical absorbance capacity was highest at $391{\mu}M$ TE in EF (in decreasing order of $117{\mu}M$ TE in BF and $64{\mu}M$ TE in HF), whereas superoxide anion radical scavenging activity ($IC_{50}$) was highest at $40{\mu}g/mL$ in EF (in decreasing order of $69{\mu}g/mL$ in BF and $98{\mu}g/mL$ in 70% ethanol extract). Inhibitory activity ($IC_{50}$) of nitric oxide (NO) production induced by LPS-activated RAW264.7 cells was highest at $62{\mu}g/mL$ in HF (in decreasing order of $104{\mu}g/mL$ in EF and $465{\mu}g/mL$ in BF). The selectivity index (ratio of inhibitory activity of NO production to cell cytotoxicity) was highest at 4.63 in EF (in decreasing order of 3.37 in HF and 2.14 in BF). In conclusion, EF showed potent antioxidant and anti-inflammatory effects with high phenolic and flavonoid contents.