• Title/Summary/Keyword: Ge channel

Search Result 92, Processing Time 0.03 seconds

Treatment of fever with traditional Chinese medicine according to Zheng on cancer patients (based on case reports)

  • Liu, Lan-Ying;Cao, Peng;Cai, Xue-Ting;Wang, Xiao-Ning;Huo, Jie-Ge;Zhou, Zhong-Ying
    • CELLMED
    • /
    • v.2 no.2
    • /
    • pp.16.1-16.5
    • /
    • 2012
  • Fever in cancer patients is often due to the following causes: evil qi and toxity stagnancy, disorders of qi and blood, deficiencies of zang and fu organs, and the disorder of yin and yang. The treatments given to cancer patients with a fever are according to five: (a) Excessive inner heat and toxicants: remove heat and the toxicant, induce purgation. We use Cheng-Qi-Tang plus Qing-Wen-Bai-Du-Yin. (b) Tangle of damp and heat, and qi stagnancy: remove damp and heat, smooth the qi channel. We use Gan-Lu-Xiao-Du-Dan or San-Ren-Tang. (c) Obvious blood and heat stagnancy: remove heat and blood stasis. We use Xue-Fu- Zhu-Yu-Tang. (d) Deficiency of spleen qi, inner heat caused by a yin deficiency: nourish spleen qi and yin to remove the inner heat. We use Bu-Zhong-Yi-Qi-Tang or Xiao-Jian-Zhong-Tang. (e) Prominent yin deficiency and hectic fever: replenish yin and remove inner heat. We use Qing-Hao-Bie-Jia-Tang or Chai- Qian-Mei-Lian-San. The pathogenesis of fever in cancer patients is complicated. We can see both deficiency and excess in one differentiation. Therefore, we must make sure of it, then we can get the most effective treatment.

A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection (조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

Utility of Lateral Circumflex Femoral Artery Perforator's 3D Image with MD-CT (MD-CT로 얻은 가쪽넙다리휘돌이 관통동맥 3D 영상의 유용성)

  • Park, Soo Ho;Shim, Jeong Su;Lee, Sang Kon;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.379-384
    • /
    • 2008
  • Purpose: Currently, using perforator artery flaps especially anterolateral thigh flaps are widely used for reconstruction of extremities, head and neck. Obtaining a precise anatomical picture prior to operation will translate to a more accurate, efficient and safe procedure. Authors used 3D-image work up via 64-slice MDCT to make a more precise preoperative plan. Methods: A total of 10 patients underwent soft tissue reconstruction with anterolateral thigh flap from December 2006 to December 2007. The 64-Channel MDCT (LightSpeed VCT, GE, USA) was used and 3D images were reconstructed. Findings from MDCT were applied to the preoperative planning and confirmed with intraoperative findings. Results: The average number of perforator arteries from lateral circumflex femoral artery was 2. The average lengths of vascular pedicle from the origin of lateral circumflex femoral artery to the first and second perforator artery were 11.0 cm and 20.0 cm, respectively. The average diameter of the pedicle artery was 2.2 mm. The locations of the perforator arteries were mapped and localized on the body surface based on the MDCT result. These were confirmed through direct visualization intraoperatively. Conclusion: MDCT has an advantage of obtaining accurate images of the general anatomy and even fine structures like perforator arteries. By using this state-of-the-art diagnostic imaging technique, it is now possible to make an operative plan safely and easily.

Bandwidth Management of WiMAX Systems and Performance Modeling

  • Li, Yue;He, Jian-Hua;Xing, Weixi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.2 no.2
    • /
    • pp.63-81
    • /
    • 2008
  • WiMAX has been introduced as a competitive alternative for metropolitan broadband wireless access technologies. It is connection oriented and it can provide very high data rates, large service coverage, and flexible quality of services (QoS). Due to the large number of connections and flexible QoS supported by WiMAX, the uplink access in WiMAX networks is very challenging since the medium access control (MAC) protocol must efficiently manage the bandwidth and related channel allocations. In this paper, we propose and investigate a cost-effective WiMAX bandwidth management scheme, named the WiMAX partial sharing scheme (WPSS), in order to provide good QoS while achieving better bandwidth utilization and network throughput. The proposed bandwidth management scheme is compared with a simple but inefficient scheme, named the WiMAX complete sharing scheme (WCPS). A maximum entropy (ME) based analytical model (MEAM) is proposed for the performance evaluation of the two bandwidth management schemes. The reason for using MEAM for the performance evaluation is that MEAM can efficiently model a large-scale system in which the number of stations or connections is generally very high, while the traditional simulation and analytical (e.g., Markov models) approaches cannot perform well due to the high computation complexity. We model the bandwidth management scheme as a queuing network model (QNM) that consists of interacting multiclass queues for different service classes. Closed form expressions for the state and blocking probability distributions are derived for those schemes. Simulation results verify the MEAM numerical results and show that WPSS can significantly improve the network’s performance compared to WCPS.

Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology (3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발)

  • Jeong-Wan Kim;Youl-Hun Seoung
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

Temporal and Spatial Variability of the Middle and Lower Tropospheric Temperatures from MSU and ECMWF (MSU와 ECMWF에서 유도된 중간 및 하부 대류권 온도의 시 ${\cdot}$ 공간 변동)

  • Yoo, Jung-Moon;Lee, Eun-Joo
    • Journal of the Korean earth science society
    • /
    • v.21 no.5
    • /
    • pp.503-524
    • /
    • 2000
  • Intercomparisons between four kinds of data have been done to estimate the accuracy of satellite observations and model reanalysis for middle and lower tropospheric thermal state over regional oceans. The data include the Microwave Sounding Units (MSU) Channel 2 (Ch2) brightness temperatures of NOAA satellites and the vertically weighted corresponding temperature of ECMWF GCM (1980-93). The satellite data for midtropospheric temperatures are MSU2 (1980-98) in nadir direction and SC2 (1980-97) in multiple scans, and for lower tropospheric temperature SC2R (1980-97). MSU2 was derived in this study while SC2 and SC2R were described in Spencer and Christy (1992a, 1992b). Temporal correlations between the above data were high (r${\ge}$0.90) in the middle and high latitudes, but low(r${\sim}$0.65) over the low latitude and more convective regions. Their values with SC2R which included the noises due to hydrometeors and surface emission were conspicuously low. The reanalysis shows higher correlation with SC2 than with MSU2 partially because of the hydrometeors screening. SC2R in monthly climatological anomalies was more sensitive to surface thermal condition in northern hemisphere than MSU2 or SC2. The first EOF mode for the monthly mean data of MSU and ECMWF shows annual cycle over most regions except the tropics. The mode in MSU2 over the Pacific suggests the east-west dipole due to the Walker circulation, but this tendency is not clear in other data. In the first and second modes for the Ch2 anomalies over most regions, the MSU and ECMWF data commonly indicate interannual variability due to El Ni${\tilde{n}$o and La Ni${\tilde{n}$a. The substantial disagreement between observations and model reanalysis occurs over the equatorial upwelling region of the western Pacific, suggesting uncertainties in the model parameterization of atmosphere-ocean interaction.

  • PDF

Intercomparison of Satellite Data with Model Reanalyses on Lower- Stratospheric Temperature (하부 성층권 온도에 대한 위성자료와 모델 재분석들과의 비교)

  • Yoo, Jung-Moon;Kim, Jin-Nam
    • Journal of the Korean earth science society
    • /
    • v.21 no.2
    • /
    • pp.137-158
    • /
    • 2000
  • The correlation and Empirical Orthogonal Function (EOF) analyses over the globe have been applied to intercompare lower-stratospheric (${\sim}$70hPa) temperature obtained from satellite data and two model reanalyses. The data is the19 years (1980-98) Microwave Sounding Unit (MSU) channel 4 (Ch4) brightness temperature, and the reanalyses are GCM (NCEP, 1980-97; GEOS, 1981-94) outputs. In MSU monthly climatological anomaly, the temperature substantially decreases by ${\sim}$21k in winter over southern polar regions, and its annual cycle over tropics is weak. In October the temperature and total ozone over the area south of Australia remarkably increase together. High correlations (r${\ge}$0.95) between MSU and reanalyses occur in most global areas, but they are lower (r${\sim}$O.75) over the 20-3ON latitudes, northern America and southern Andes mountains. The first mode of MSU and reanalyses for monthly-mean Ch4 temperature shows annual cycle, and the lower-stratospheric warming due to volcanic eruptions. The analyses near the Korean peninsula show that lower-stratospheric temperature, out of phase with that for troposphere, increases in winter and decreases in summer. In the first mode for anomaly over the tropical Pacific, MSU and reanalyses indicate lower-stratospheric warming due to volcanic eruptions. In the second mode MSU and GEOS present Quasi-Biennial Oscillation (QBO) while NCEP, El Ni${\tilde{n}}$o. Volcanic eruption and QBO have more impact on lower-stratospheric thermal state than El Ni${\tilde{n}}$o. The EOF over the tropical Atlantic is similar to that over the Pacific, except a negligible effect of El Ni${\tilde{n}}$o. This study suggests that intercomparison of satellite data with model reanalyses may estimate relative accuracy of both data.

  • PDF

Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom (인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향)

  • Wang, Jihwan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.495-501
    • /
    • 2014
  • The objective of this study was to evaluate the differences and reproducibility of Hounsfield unit (HU) value and volume measurements on different computed tomography (CT) scanner types and different collimations by using a gelatin phantom. The phantom consisting of five synthetic simulated calculus spanning diameters from 3.0 mm to 12.0 mm with 100 HU was scanned using a two-channel multi-detector row CT (MDCT) scanner, a four-channel MDCT scanner, and two 64-channel MDCT scanners. For all different scanner types, the thinnest possible collimation and the second thinnest collimation was used. The HU values and volumes of the synthetic simulated calculus were independently measured three times with minimum intervals of 2 weeks and by three experienced veterinary radiologists. ANOVA and Scheff$\acute{e}$ test for the multiple comparison were performed for statistical comparison of the HU values and volumes of the synthetic simulated calculus according to different CT scanner types and different collimations. The reproducibility of the HU value and volume measurements was determined by calculating Cohen's k. The reproducibility of HU value and volume measurements was very good. HU value varied between different CT scanner types, among different beam collimations. However, there was not statistically significant difference. The percent error (PE) decreased as the collimation thickness decreased, but the decrease was statistically insignificant. In addition, no statistically significant difference in the PEs of the different CT scanner types was found. It can be concluded that the CT scanner type insignificantly affects HU value and the volumetric measurement, but that a thinner collimation tends to be more useful for accurate volumetric measurement.

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF