• Title/Summary/Keyword: Gauge error

Search Result 141, Processing Time 0.026 seconds

A study on the measurement of two-dimensional in-plane displacements of the plate with a circular hole by ESPI method (ESPI에 의한 원공판의 2차원 면내변위 측정에 관한 연구)

  • Kim, Kyoung Suk;Choi, Hyoung Chol;Yang, Seung Pil;Kim, Hyoung Soo;Hong, M.S.;Jung, W.K.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.161-170
    • /
    • 1994
  • This paper presents the performance and problems in analysis method and testing system of Electronic Speckle Pattern Interfermetry(ESPI) method, in measuring two-dimensional in- plane displacement. The analysis result of measurement by ESPI is quite comparable to that of measurement by strain gauge method. This implieds that the method of ESPI is a very effective tool in non-contact two-dimensional in-plane strain analysis. But there is a controversial point, measurement error. This error is discussed to be affected not by ESPI method itself, but by its analysis scheme of the interference fringe, where the first-order interpolation has been applied to the points of strain measured. Further development of advanced first-order interpolation method is being undertaken for the more precise in-plane strain measurement.

  • PDF

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

FE Techniques for the Accurate Prediction of Part Dimension in Cold Forging (냉간 단조품의 치수 정밀 예측을 위한 유한 요소 해석 기술)

  • 이영선;권용남;이정환
    • Transactions of Materials Processing
    • /
    • v.13 no.1
    • /
    • pp.3-8
    • /
    • 2004
  • The improvement of dimensional accuracy for forged part is one of major goals in cold forging industry. There are many problems in controlling the dimension by the trial-and-error, especially for a precision forged gear. A FEM analysis has been used in developing the forging technology. However, FE techniques have to be reconfirmed for predicting accurately the dimension of forged part. In this study, the effects of elastic characteristics and temperature changes are investigated by the comparisons between experimental and FEA in cold forging. When FE models related with elastic characteristics are considered practically, FE results could predict the part dimension within the range of $10\mu\textrm{m}$. And if thermal effects also are considered additionally, the predicted dimensions are well coincided with the experimental down to about $5\mu\textrm{m}$.

A Study on the Development of the CMM Probe using Force-Sensor (힘 센서를 이용한 CMM용 프로브 개발을 위한 연구)

  • 송광석;권기환;박재준;조남규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.411-415
    • /
    • 2002
  • In this paper, a mechanical probe for CMM (Coordinate Measuring Machine) with a three-axis force-sensing unit is proposed, which is capable of measuring an actual contact position without the lobbing effect and the pre-travel error. The force-sensing unit detects the external force, which is act on the stylus of CMM during the measuring process. Thus, the contact point of the stylus of CMM can be estimated ken the direction of measured force components. Based on the structural analysis of the proposed CMM probe, the transformation matrix is derived and calibrated so that it shows linear relationships between the estimated force components from the output voltages and the real input forces. And, the relationships are verified through the computer simulation. The results show that the proposed mechanical probe is very useful fur detecting the contacting force components on measuring process of CMM.

  • PDF

Extended State Estimation Algorithm in Power Systems (확장된 전력 상태추정 알고리즘 개발)

  • Shon, H.S.;Ha, Y.K.;Ryu, H.S.;Moon, Y.H.;Song, K.B.;Park, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.178-180
    • /
    • 2001
  • State estimation in power system is to estimate state variable value which minimizes the error from the real state measured by the gauge and connection state of the circuit breaker. In the past, it was difficult to determine measure function considering the correlation of the measured values. In this paper, an extended state estimation is proposed to process easily various kinds of estimation variable. The proposed algorithm is developed by expanding state variable concept based on many measured values and treating correlation between estimation variable and state variable, it is considered that the state variable satisfy some limitations named "Equality Limitation conditions".

  • PDF

h-index, h-type Indices, and the Role of Corrected Quality Ratio

  • Tahira, Muzammil;Alias, Rose Alinda;Bakri, Arayti;Shabri, Ani
    • Journal of Information Science Theory and Practice
    • /
    • v.2 no.4
    • /
    • pp.20-30
    • /
    • 2014
  • This study examines the foremost concerns related to most noted research performance index. The most popular and widely acceptable h-index underestimates the highly visible scientist, the middle order group, due to citation distribution issues. The study addresses this issue and uses 'Corrected Quality Ratio' (CQ) to check the implicit underpinnings as evident in h-index. CQ helps to incorporate the aspects of a good research performance indicator. This simple revision performs more intimately and logically to gauge the broader research impact for all groups and highly visible scientists with less statistical error.

A study on the flash over characteristics in space and surface series air gaps (공간연면 직렬간극의 섬락방전특성에 관한 연구)

  • 김원섭
    • 전기의세계
    • /
    • v.25 no.1
    • /
    • pp.87-94
    • /
    • 1976
  • The characteristic of flashover electric discharge has been brought to light in this paper for the situation in which the space and creeping gaps are laid out in series. The result of this study has disclosed the facts that the over all flashover characteristics have three kind of features such as unilateral increase after increase, and increase after decrease in compliance with varied layout method and relative magnitude of gap length, and accordingly there exist a ratio among the magnitudes of gap length and a proper layort method through which the over all flashover voltage reaches the highest. Also involved with this study is the theoretic analysis of flashover characteristics even in the case of creeping electric discharge from hand tip of the gauge, where the over all value of flashover voltage can be estimated from the peculiar value of flashover voltage and flicker voltage for the space and creeping gap within the extent of 5% error.

  • PDF

A STUDY OF ELECTRONIC DEVICE FOR THE MEASURING THE TONGUE PRESSURE (설압력 측정품구에 관한 연구)

  • Lee, Ho-Yong;Kim, ki-Hwan;Chung, Kyung-Hoon
    • The Journal of the Korean dental association
    • /
    • v.15 no.12
    • /
    • pp.1027-1030
    • /
    • 1977
  • It has been widely believed that the exact measurement of the forces exerted on teeth and its structures by the lingual and perioral musculatures such as lip, cheek and tongue is important and significant in dentistry. Such measuring, moreover, is highly emphasized the importance of the fact that it can be of much help to study the physiological function displayed in the oral cavity. Recognizing the importance of measuring the pressures, the author has devised an electronic device consisting of pressure transducers utilizing reistance-strnain gauges. This electronic strain gauge was very easy to manipulate and its scale error was extremely minimized, unaffected by mouth temperature, mosture and external forces Author was able to read its results with attached meter without using calibration chart. Futhermore, the sensitivity of this electronic device was extremely high, Thus it facilitated to measure a force from 0 to 230 grams.

  • PDF

ESTIMATION OF SEAWATER LEVEL ON SEA FARMS USING L-BAND RADAR INTERFEROMETRY

  • Kim, Sang-Wan;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.312-316
    • /
    • 2002
  • Satellite radar interferometry data shows a strong coherent signal on oyster sea farms where artificial structures installed on the bottom. We obtained 21 highly coherent interferograms from eleven JERS-1 SAR data sets despite of large orbital baseline (~2 km) or large temporal baseline (~l year). The phases observed in sea farms are probably induced by double bouncing on sea surface, and consequently reveal a tide height variation. To restore the absolute sea level changes we counted the number of wrapping by exploiting the intensity of backscattering. Backscattering intensity is closely correlated with the change in water surface height, while interferometry gives the detailed variation within the limit of 2$\pi$ (or 15.3 cm). Comparing the radar measurements with the tide gauge records yielded a correlation coefficient of 0.96 and an ms error of 6.0 cm. The results demostrate that radar interferometry is promising to measure sea level.

  • PDF

Position/force Control using 6-axis Compliance Device for Chemical Coupler Assembly (케미컬 커플러 체결을 위한 순응장치를 이용한 위치/힘 동시제어)

  • Park, Shi-Baek;Kim, Han-Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.909-915
    • /
    • 2022
  • In this paper, a robot automation technology for chemical tank lorry unloading is presented. Handling chemical coupler between tank lorry and ACQC system may be hazardous or toxic to human operators, therefore robot automation is essential. Due to tight tolerance between couplers, even small pose error may result in very large internal force. In order to resolve the problem, compliance between male and female couplers should be introduced with 6-axis compliance device with F/T sensing. The proposed robot automation system consists of a collaborative robot, 6-ax is compliance device with F/T sensing, linear gripper, and robot vision. The position/force control algorithm and experimental results for assembling chemical couplers are presented.