• Title/Summary/Keyword: Gas-combined

Search Result 947, Processing Time 0.025 seconds

A Performance prediction of Gas Turbine using syngas fuel in IGCC (가스화복합발전에서 Syngas 연료를 사용하는 가스터빈의 성능예측)

  • Seo, Seok-Bin;Kim, Jong-Jin;Chung, Jae-Hwa;Ahn, Dal-Hong
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.878-884
    • /
    • 2001
  • IGCC(Integrated Gasification Combined Cycle) power plant are becoming more attractive because of fuel flexibility and low emission. In this study, performances are evaluated when the low caloric value syngas fuels producted in gasification process is used a gas turbine originally designed naturel gas fuel. Using GateCycle computational thermal analysis model, performances of GE 7FA gas turbine are predicted for using four types of syngas. Also, off design performance is presented for firing syngas fuel in the gas turbine.

  • PDF

Fault Diagnostic Expert System Using Dissolved Gas Analysis in Transformer (유중가스를 이용한 변압기 고장진단용 전문가 시스템 개발)

  • Jeon, Young-Jae;Yoon, Yong-Han;Kim, Jae-Chul;Yun, Sang-Yun;Choi, Do-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.859-861
    • /
    • 1996
  • This paper presents the novel fault diagnostic expert system based on dissolved gas analysis(DGA) techniques in power transformer. The uncertainty of key gas analysis, norm threshold, and gas ratio boundaries are managed by using a fuzzy set concept. The uncertainty of rules are handled by fuzzy measures. Trend analysis through the monthly increment of key gas and DGA analysis are combined by the Dempster-Shafer theory, and the state of transformer and confidence factor are yielded by using this combined analysis. To verify the effectiveness of the proposed diagnosis technique, the expert system has been tested by using KEPCO's transformer gas records.

  • PDF

Performance Analysis of a Reheat-cycle Gas Turbine for Combined Cycle Power Plants Using a Simulation Software for Chemical Process Plants (화학공정 플랜트 해석용 소프트웨어를 이용한 복합화력 발전용 재열 사이클 가스터빈의 성능특성에 관한 연구)

  • Park Min-Ki;Ro Sung-Tack;Sohn Jeong-Lak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.472-479
    • /
    • 2006
  • Recently, various methods have been developed to improve the performance of gas turbines for combined cycle power plants. This paper especially focused on the gas turbine with a reheat process. The purpose of this study is to analyze performance characteristics of a reheat-cycle gas turbine on both a design point and off-design operations. Results of the parametric study of this model show how operating and design parameters influence on the performance of the gas turbine. Moreover, possibilities for the analysis of off-design performance based on a self-generated compressor performance characteristic map are presented.

Performance Evaluation of Combined Heat and Power Plant Configurations -Thermodynamic Performance and Simplified Cost Analysis (열병합 발전소의 구성안별 성능 평가 방안 - 플랜트 열성능 및 단순화 발전단가 분석)

  • Kim, Seungjin;Choi, Sangmin
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2013
  • Thermodynamic and economic analyses of various types of gas turbine combined cycle power plants have been performed to establish criteria for optimization of power plants. The concept of efficiency, in terms of the difference in energy levels of electricity and heat, was introduced. The efficiency of power and heat generation by power plants with other purposes was estimated, and power generation costs were figured out for various types of combined heat and power plants(i.e., fired and unfired, condensing and non-condensing modes, single or double pressure HRSG).

DEVELOPMENT OF COMBIND WELDING WITH AN ELECTRIC ARC AND LOW POWER CO LASER

  • Lee, Se-Hwan;Massood A. Rahimi;Charles E. Albright;Walter R. Lempert
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.176-180
    • /
    • 2002
  • During the last two decades the laser beam has progressed from a sophisticated laboratory apparatus to an adaptable and viable industrial tool. Especially, in its welding mode, the laser offers high travel speed, low distortion, and narrow fusion and heat-affected zones (HAZ). The principal obstacle to selection of a laser processing method in production is its relatively high equipment cost and the natural unwillingness of production supervision to try something new until it is thoroughly proven. The major objective of this work is focused on the combined features of gas tungsten arc and a low-power cold laser beam. Although high-power laser beams have been combined with the plasma from a gas tungsten arc (GTA) torch for use in welding as early as 1980, recent work at the Ohio State University has employed a low power laser beam to initiate, direct, and concentrate a gas tungsten arcs. In this work, the laser beam from a 7 watts carbon monoxide laser was combined with electrical discharges from a short-pulsed capacitive discharge GTA welding power supply. When the low power CO laser beam passes through a special composition shielding gas, the CO molecules in the gas absorbs the radiation, and ionizes through a process known as non-equilibrium, vibration-vibration pumping. The resulting laser-induced plasma (LIP) was positioned between various configurations of electrodes. The high-voltage impulse applied to the electrodes forced rapid electrical breakdown between the electrodes. Electrical discharges between tungsten electrodes and aluminum sheet specimens followed the ionized path provided by LIP. The result was well focused melted spots.

  • PDF

Performance and Economic Analysis of Natural Gas/Syngas Fueled 100 MWth Chemical-Looping Combustion Combined Cycle Plant (천연가스/합성가스 이용 100 MWth 매체순환연소 복합발전 플랜트의 성능 및 경제성 평가)

  • Park, Young Cheol;Lee, Tai-yong;Park, Jaehyeon;Ryu, Ho-Jung
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • In this study, performance and economic analysis of natural gas/syngas fueled 100 MWth chemical-looping combustion (CLC) combined cycle plant were performed. Net efficiency of both cases was 53~54%, corresponding to previous research. We used Chemical Engineering Plant Cost Index and Guthrie method to evaluate plant cost. For syngas fueled CLC combined cycle plant, the plant cost was higher since lower heating value(LHV) of syngas was lower than that of natural gas and cost of electricity(COE) was also higher since the cost of syngas was higher than that of natural gas. By sensitivity analysis, it was shown that the cost of syngas should be less than 5.3 $/GJ in order to make COE lower than 5.8 ¢/kWh which was COE of natural gas fueled CLC combined cycle plant.

Combined Treatment of Chlorine Dioxide Gas, Mild Heat, and Fumaric Acid on Inactivation of Listeria monocytogenes and Quality of Citrus unshiu Marc. during Storage (이산화염소 가스 훈증, 중온 열수 및 푸마르산 병합처리가 감귤의 미생물학적 안전성 및 저장 중 품질에 미치는 영향)

  • Kim, Hyun Gyu;Min, Sea Cheol;Oh, Deog Hwan;Koo, Ja Jun;Song, Kyung Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.8
    • /
    • pp.1233-1238
    • /
    • 2016
  • Combined treatment of chlorine dioxide ($ClO_2$) gas, mild heat, and fumaric acid was performed to reduce microbial growth and maintain quality of Citrus unshiu during storage at $4^{\circ}C$. Citrus unshiu fruits were treated with $ClO_2$ gas (15 or 30 ppmv), mild heat (40, 50, or $60^{\circ}C$), and fumaric acid (0.1, 0.3, or 0.5%). Combined treatment of 15 or 30 ppmv $ClO_2$ gas, $50^{\circ}C$ mild heat, and 0.5% fumaric acid reduced populations of inoculated Listeria monocytogenes by 3.5~3.7 log CFU/g. In addition, combined treatment decreased populations of yeast and molds in Citrus unshiu by 2.54 log CFU/g after 30-day storage at $4^{\circ}C$. Combined treatment also reduced the decay rate by 48% after 30 days of storage compared with the control. Total solid content, titratable acidity, and color values were not significantly affected by the combined treatment. Therefore, combined treatment of $ClO_2$ gas, mild heat, and fumaric acid can be a useful hurdle technology to improve microbial safety and quality of Citrus unshiu during storage.

Thermodynamic Performance Evaluation of an Integration Design between the Combined-cycle and Air Separation Unit in an IGCC Power Plant (IGCC 발전 플랜트에서 복합발전공정-공기분리장치의 연계에 관한 열역학적 성능 평가)

  • Won, On Nu-ri;Kim, Hyun-jeong;Park, Sung-koo;Na, Jong-moon;Choi, Gyung-min;Kim, Duck-jool
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.49-51
    • /
    • 2012
  • In this paper, the integration issue, such as an air-side integration design between the gas turbine and air separation unit, is described and analyzed by the exergy and energy balance of the combined-cycle power block in an IGCC power plant. The results showed that the net power of the system was almost same, but that of the gas turbine was decreased as the integration degree increased. The highest exergy loss was occurred in the combustor of gas turbine, which was affected by the chemical reaction, heat conduction, mass diffusion, and viscous dissipation.

  • PDF

Introduction of Off-Gas Power Plant and Localization Development of Auxiliary Equipment (부생복합발전 소개와 주요설비 국산화를 위한 연구)

  • Ko, Minseok;Kim, Dohyung;Lee, Dongsu;Lee, Seong-geun
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.127-128
    • /
    • 2013
  • Off-gas power plant is a renewable energy power plant which generate electrical energy using the low calorie FOG and BFG as main fuel. This combined cycle power plant is comprised of gas turbines, gas compressors, steam turbines, generators, and auxiliary equipment such as gas mixer, mixing tank, and gas cooler. In this paper, a off-gas power plant and development of its several equipment using CFD are introduced.

  • PDF