• Title/Summary/Keyword: Gas sensor

Search Result 1,615, Processing Time 0.027 seconds

Characteristics of Solid Electrolyte $CO_2$ Gas Sensors (고체전해질을 사용한 $CO_2$가스센서의 응답기구)

  • Kim, G.Y.;Park, Y.P.;Lee, S.I.;Lee, W.J.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.562-564
    • /
    • 2002
  • In recent years, environments of our globe has been getting worse as a result of rapid growth of socioeconomic activities. The global environmental issues of acid rain, green house effect and ozone depletion are caused by various chemical pollutants, emitted from industries, automobiles and home. Most of these pollutants are produced by combustion processes. CO2 as a chief criminal of the greenhouse effect is a main combustion product of fossil fuels. Development of solid-state electrochemical devices for detecting CO2 is demonstrated based on various combination of solid electrolytes and auxiliary sensing materials. The object of this research is to develop various sensor performance for solid electrolyte gas sensor, and to test gas sensor performance manufactured. So we try to present a guidance for developing potential type gas sensor. We concentrated on development of manufacturing process and performance test.

  • PDF

Gas Tank Microleakage Reception Characteristics According to Thickness of the First Matching Layer of Ultrasonic Sensor (초음파 센서의 1차 정합층 두께에 따른 가스탱크 미세누설 수신특성)

  • Seo, Wonjun;Son, Seongjin;Im, Seokyeon
    • Tribology and Lubricants
    • /
    • v.37 no.5
    • /
    • pp.164-171
    • /
    • 2021
  • Ultrasonic sensors show various reception characteristics based on the density of the measurement medium; hence, they are used in various fields to benefit from the characteristics of ultrasonic signals. In this study, the reception characteristics according to the thickness of the first matching layer are compared and analyzed for application to gas tank microleak detection. Accordingly, three types of sensors are manufactured with varying thicknesses of the first matching layer, namely 4.8 mm, 5.1 mm, and 5.5 mm; further, a direct measurement method is used wherein the sensor is attached to the inside of the chamber. Experiments are conducted to observe the phase change due to microleakage, which is the most linear in the sensor with the 4.8 mm thick first matching layer. This is assumed to be the result of stable signal transmission and reception with little phase deviations over time because the first matching layer is closest to the ultrasonic wavelength. The other sensors show nonlinear results with increasing thickness of the first matching layer. Through this study, it is found that appropriately selecting the thickness of the first matching layer of the ultrasonic sensor can greatly influence sensor reliability.

System and method for detecting gas using smart-phone (스마트폰을 이용한 가스검출시스템 및 검출 방법연구)

  • Bang, Yong-Ki;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.129-137
    • /
    • 2015
  • This study is in regard to the gas detection system and gas detection method utilizing smart phone. This study includes; 1) the sensor module attached to the smart phone to detect and measure flammable gas or toxic gas; and 2) gas detection APP which is installed inside the smart phone and recognizes the user information and location information automatically by reading RFID tag indicating the user or the location to detect gas through the contact area where RFID and blue tooth reader is installed inside of the above mentioned smart phone, and then measures the combustible gas or toxic gas by operating above mentioned sensor module and obtains the data thus measured, and above mentioned smart phone is characterized by its transmission of the above mentioned user information, location information and measured data which are obtained by above mentioned gas detecting APP to operation server via communication network. With this, reliability for the location detecting gas by the user, the result of the measurement, etc. can be secured. Furthermore, this provides the effect of preventing artificial manipulation at the time of input which is associated with the identification of the user to be measured by utilizing removable sensor module and application or the mistake resulted from wrong input by the user. In addition, by transmitting the measured data from the sensor module carrying out gas detection to operation server, this provides the effect of making it possible to process the data thus collected to a specialized data for combustible gas or toxic gas.

Optical waveguide structure design of Non-dispersive Infrared (NDIR) CO2 gas sensor for high-sensitivity (이산화탄소 검출을 위한 고감도 비분산 적외선 가스센서의 광도파관 구조 설계)

  • Yoon, Jiyoung;Lee, Junyeop;Do, Namgon;Jung, Daewoon
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.331-336
    • /
    • 2021
  • The Non-dispersive Infrared (NDIR) gas sensor has high selectivity, measurement reliability, and long lifespan. Thus, even though the NDIR gas sensor is expensive, it is still widely used for carbon dioxide (CO2) detection. In this study, to reduce the cost of the NDIR CO2 gas sensor, we proposed the new optical waveguide structure design based on ready-made gas pipes that can improve the sensitivity by increasing the initial light intensity. The new optical waveguide design is a structure in which a part of the optical waveguide filter is inclined to increase the transmittance of the filter, and a parabolic mirror is installed at the rear end of the filter to focus the infrared rays passing through the filter to the detector. In order to examine the output characteristics of the new optical waveguide structure design, optical simulation was performed for two types of IR-source. As a result, the new optical waveguide structure can improve the sensitivity of the NDIR CO2 gas sensor by making the infrared rays perpendicular to the filter, increasing the filter transmittance.

ART2 Neural Network Applications for Diagnosis of Sensor Fault in the Indoor Gas Monitoring System

  • Lee, In-Soo;Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1727-1731
    • /
    • 2004
  • We propose an ART2 neural network-based fault diagnosis method to diagnose of sensor in the gas monitoring system. In the proposed method, using thermal modulation of operating temperature of sensor, the signal patterns are extracted from the voltage of load resistance. Also, fault classifier by ART2 NN (adaptive resonance theory 2 neural network) with uneven vigilance parameters is used for fault isolation. The performances of the proposed fault diagnosis method are shown by simulation results using real data obtained from the gas monitoring system.

  • PDF

NO Gas Sensing Characteristics of Single-Walled Carbon Nanotubes and Heating Effect (단층 탄소나노튜브의 일산화질소 가스에 대한 감응특성과 열처리 효과)

  • Kim, Min-Ju;Yun, Kwang-Hyun;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.292-297
    • /
    • 2004
  • Carbon nanotubes (CNT) were synthesized by arc-discharge method. To fabricate CNT sensor, CNT powder was dispersed in ${\alpha}$-Terpinol($C_{10}H_{17}OH$) solution. The CNT tilms were fabricated by screen printing method on the interdigitated Pt/Pd alloy electrode. The microstructure of CNT film was observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). In order to investigate the gas sensing characteristics of the film, the CNT film was experimented to measure NO response and recovery time. The CNT sensor with a heater was compared to that without a heater. And this sensor shows better reproductibility and faster recovery time than another CNT sensors. We suggest the possibility to utilize a CNT as new sensing materials for environmental monitoring.

Analysis of Conductivity Gas by using Automotive Dynamo-Meter (차량용 Dynamo-Meter를 이용한 도전성가스 분석연구)

  • 전영갑;서길수;노형우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.112-118
    • /
    • 2001
  • In this study the leakage current measurement method based on a porous ceramic is applied to check the conductive substance caused by the ionized particles. By using engine and chassis dynamometer and an experiment vehicle, in which the hydrocarbon sensor (HC sensor) was exposed to the exhaust gas to create the electrical signal, the HC sensor in the exhaust line checked the conductive ions in emission gas. Generally the output electrical signal of HC sensor is followed with amount of hydrocarbon in the experiments in cold start and operation. By combining the electrical signal, a measure of conductivity of exhaust gas with hydrocarbon can be provided by OBD (On Board Diagnosis) II and EMS (Engine Management System).

  • PDF

A Study on the Measurement of Halitosis of Human Mouth with Chemical Gas Sensor Arrays (화학 가스센서를 활용한 구취측정 방법에 관한 연구)

  • Lee, Seok-Jun;Kim, Sun-Tae;Kim, Han-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.279-285
    • /
    • 2011
  • This study was carried out to apply chemical gas sensors for the identification of bad breath which is one of the important sensitive problem for the humans' daily life. Seven sensors, including five semiconductor sensors and two electrochemical sensors, were tested for the three panels three times in several conditions. The results showed that the reproducibility of sensors were generally good, and electrochemical sensors showed better reproducibility while semiconductor sensors showed better sensitivity. No rinsing before measurement showed relatively better results in terms of both sensitivity and reproducibility. Semiconductor gas sensors for hydrogen sulfide shows the highest sensitivity, and it was recommended to use the odor-free bag for the measurement of bad breath.

An Experimental Study on the Transient Response of Hydrogen Sensors Dependent on Gas Temperature and Humidity (가스의 온도 및 습도 변화에 따른 수소 센서 응답 특성에 대한 실험적 연구)

  • Kim, Young-Doo;Chung, Tae-Yong;Shin, Dong-Hoon;Nam, Jin-Hyun;Kim, Young-Gyu;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.5
    • /
    • pp.15-19
    • /
    • 2009
  • In this study, the transient responses of hydrogen sensor against abrupt hydrogen release was experimentally studied for three most common types of hydrogen sensors, i.e. the semiconductor type, electrochemical type, and catalytic combustion type. The experimental study was conducted using a 1% hydrogen - 99% nitrogen mixture gas as the standard gas, while the temperature and relative humidity (RH) of the mixture gas was varied from $25^{\circ}C$ to $50^{\circ}C$ and from 50% to 100%, respectively. The temperature of the mixture gas was found to influence the output signal levels of hydrogen sensors, especially the catalytic combustion type. However, the effect of RH on the sensor response was not noticeable in the present experimental study. Thus, the signal levels of hydrogen sensors, in case of catalytic gas sensor need to be calibrated dependent on gas temperature, when the accurate determination of hydrogen concentration is important.

  • PDF

Hydrogen Gas Sensor Performance of a p-CuO/n-ZnO Thin-film Heterojunction (p-CuO/n-ZnO 이종접합 박막 구조의 수소 가스 특성 평가)

  • Yang, Yijun;Maeng, Bohee;Jung, Dong Geon;Lee, Junyeop;Kim, Yeongsam;An, Hee Kyung;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.337-342
    • /
    • 2022
  • Hydrogen (H2) gas is widely preferred for use as a renewable energy source owing to its characteristics such as environmental friendliness and a high energy density. However, H2 can easily reverse or explode due to minor external factors. Therefore, H2 gas monitoring is crucial, especially when the H2 concentration is close to the lower explosive limit. In this study, metal oxide materials and their p-n heterojunctions were synthesized by a hydrothermal-assisted dip-coating method. The synthesized thin films were used as sensing materials for H2 gas. When the H2 concentration was varied, all metal oxide materials exhibited different gas sensitivities. The performance of the metal oxide gas sensor was analyzed to identify parameters that could improve the performance, such as the choice of the metal oxide material, effect of the p-n heterojunctions, and operating temperature conditions of the gas sensor. The experimental results demonstrated that a CuO/ZnO gas sensor with a p-n heterojunction exhibited a high sensitivity and fast response time (134.9% and 8 s, respectively) to 5% H2 gas at an operating temperature of 300℃.