• Title/Summary/Keyword: Gas safety check

Search Result 55, Processing Time 0.027 seconds

A Study on the Actual Condition of Gas Equipment and Gas Safety Consciousness Survey to Improve Gas Safety of Gas Consumers (가스 소비자들의 가스안전성 제고를 위한 가스기기 사용 실태 및 가스안전의식 조사에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.465-475
    • /
    • 2017
  • As a result of a survey on households using gas, gas safety accidents have been declining linearly in 2006. However, when analyzing the causes of gas accidents, accidents detail caused by carelessness have increased to 62%It is analyzed that urgent measures are needed. In addition, 7 households per 10 households perceive city gas as safe, but 30% of them recognize that gas safety accidents are likely to occur in their homes in the future. Even though city gas use is relatively safe,It is recognized that there is a risk. Although the perception of the gas safety of the city gas consumers is not related to the age and gender income level, it is analyzed that it is highly educated and experienced direct or indirect gas safety accident, the perception of safety was relatively low. In order to reduce gas safety accidents, the installation of gas safety equipment for elderly households should be continuously supplied. As a result of investigating the disposal costs in case of various disasters, 66% of the insurance costs were found to be highly dependent on insurance. In addition, to reduce gas safety accidents, the installation of gas safety devices for elderly households should be continuously implemented.

A Study on the Optimal Installation Technology of LPG Storage Tank through Taguchi Method (다구찌 기법을 통한 LPG 저장탱크시공방법의 최적화에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Paek, Seung-Cheol;Lee, Jong-Rark
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.98-102
    • /
    • 2010
  • LPG (Liquefied Petroleum Gas) vehicles in metropolitan area are being applied to improve air quality and have been proven effective for the reduction of air pollutant. In addition, the demand of gas as an eco-friendly energy source has being increased. With the LPG filling station is also increasing every year. These gas stations are required to install the securest storage tank because of possibility of causing huge loss of life and property. Therefore, in this paper, underground containment type is proposed as installation of the LPG storage tank using Taguchi method, which is considered to be more safe, economical, efficient, easy checking and simple construction method than any other. If leakage, economics, real estate utilization rate, safety, easy to check, simple construct about above ground, buried underground and underground containment storage tank are analyzed by Taguchi method, real estate utilization rate, economic and safety in turn are improved. Therefore, the underground containment storage tank is a optimal installation technology.

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

A Comparative Study on the Safety Management Status of LP Gas Fueled Vehicles in Korea and Foreign Countries (LP가스 연료사용 자동차의 국내외 안전관리현황 비교 연구)

  • Tak, Song-Su;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.49-56
    • /
    • 2009
  • This thesis suggests ways for ensuring the safety of domestic autogas (liquefied petroleum gas) vehicles by conducting comparison and analysis on the status of market diffusion and safety management scheme in foreign countries as well as in Korea. According to the result of the survey on the status of domestic autogas safety management, the national scheme to secure the safety of autogas vehicles seems neither well-organized nor sufficiently-controlled. Actually, the gas leakage check-ups conducted for 5,000 autogas cars revealed that about 4 percent of them had leakage problems. As a result, it was acknowledged that the autogas safety regulations being operated in advanced countries need to be selectively introduced for the domestic autogas industry. Consequently, in line with the recent permission to use autogas as a fuel for subcompact cars etc., this thesis is recommending some methods to enhance the safety management scheme for autogas cars such as the amendment of facility regulations including the ventilation of underground parking lots, mandatory attachment of labels claiming autogas cars and indicating periodical inspections etc.

  • PDF

A Study on Safety and Operational Management System for CNG Filling Stations (CNG충전소 안전.운영 관리를 위한 시스템 구축에 관한 연구)

  • Yang, Jae-Mo;Kim, Bum-Su;Yong, Jong-Won;Ko, Byung-Seok;Lee, Dong-Hyuk;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.8-13
    • /
    • 2011
  • All over the nation, a lot of industrial complex utilize gas as their energy source. Possibilities are fire, explosion, and leakage could happen any time in these large complexes. To prevent these tragic accidents and to minimize the damage when the accident occurs, the development of diagnostic technology for these facilities is imperative. The safety check is conducted on an individual and partial basis, currently. Accordingly, the accumulation and improvement of the safety management technology is necessary in order to make all the different checking techniques and management systems compatible, since checking processes, result interpretation techniques, and subsequent prognoses are not the same. The program provides damage scenarios from gas leakage. The output enables policy makers to predict the degree of infliction. Through this program, engineers are able to design an effective gas safety program to operate and maintain ubiquitous gas facilities.

Study on Fire.Explosion Accidents Prediction Model Development of LPG Vaporizer (LPG 기화기의 화재.폭발사고 예측모델개발에 관한 연구)

  • Ko, Jae-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.28-36
    • /
    • 2010
  • We have garnered 3,593 data of gas accidents reported for 12 years from 1995, and then analyzed the LPG vaporizer accidents according to their types and causes based on the classified database. According to the results the gas rupture has been the most common accident followed by the release, explosion and then fire accidents, the most frequent accident-occurring sub-cause is LPG check floater faults. In addition, we have applied the Poisson Probability Functions to predict the most-likely probabilities of fire, explosion, release and rupture with the LPG vaporizer in the upcoming 5 years. In compliance with Poisson Probability Functions results, in the item which occurs below 3 "LPG-Vaporizer-Fire", in the item which occurs below 5 "LPG-Vaporizer-Products Faults-Check Floater" and the item which occurs below 10 appeared with "LPG-Vaporizer-Products Faults". From this research we have assured the successive database updating will highly improve the anticipating probability accuracy and thus it will play a key role as a significant safety- securing guideline against the gas disasters.

Development of Performance Verification Method for Components of IoT-based Industrial Valve Safety Management System (IoT 기반 산업용 밸브 안전관리 시스템 구성장치의 성능검증 방안 개발)

  • Kim, Jae-Ok;Lyu, Geun-Jun;Lee, Kyung-Sik;Kim, Jung-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.10-19
    • /
    • 2020
  • Valve leak accidents in petrochemistry plants and gas utilities cause human and property damage. The main reason why happen gas inhalation, poisoning, fire and explosion accidents is gas valve leakage. To prevent gas leakage, inspectors check the facilities in the field. And they are at risk of gas leak accidents. So we applied IoT-based risk assessment, monitoring and automatic control system. It can detect both internal and external gas leakage, do real-time monitoring of industrial valve in the plant by using hybrid sensor. As the new safety management system for industrial valve is developed, it needs method to evaluate device performance and environmental components for the system. This study is about development of method to verify performance of the explosion-proofed hybrid sensing system include gas detector and optical fiber sensor supporting wire and wireless communication.

Analyzing Safety Factors of Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2021
  • Purpose: Swimming industry is improving faster than the other types of sport industries and populations of participating swimming are promptly increasing. Lack of recognition of fire safety in swimming facilities is issues related-studies has only recently begun to pay attention. This study is to review and extract fire safety factors for managing swimming pool. Research design, data, and methodology: The study reviewed related-ordinances, governmental documents, and studies discussing safety management of sport facility. Given the literature review, the study produced an initial construct presenting items and factors including fire safety elements and experts' review were conducted to ensure conceptual validity. Finally, the study generated the final factors and subitems representing fire safety elements for swimming pool management. Results: The study confirms factors and elements as follows: the study identifies fire safety equipments as first factors presenting fire extinguisher' place, its proper run, check list and so forth, Second factor is warning system including fire warning equipment, its proper operation, sprinkler and its proper operation, switch and lamp of emergency panel and their proper run and so on. Third factor is evacuation system including a fire exit, exit sign, broadcasting equipment, and their proper operation, and so on. The other factors are an electronic equipment and its subelements, gas management including safety management of LPG, gas valve, pipe, and fire prevention facility including a fire door and its proper operating. Conclusions: Regarding safety management of swimming pool, further discussions and implications were made, and future directions for related-studies were discussed.

Development of Tank Lorry Monitoring System for Safety Using Intelligent Computing Device (지능형 단말기를 사용한 탱크로리 운행 안전 모니터링 시스템 개발)

  • Lee, Choon-Young;Bae, Ki-Man;Park, Geun-Young;Lee, Dong-Jin;Lim, Jeong-Sik;Lee, Sang-Ryong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.42-47
    • /
    • 2008
  • It is important for national safety that tank lorry or bulk lorry which is carrying toxic gas or explosive materials should be monitored during the maneuvering from starting point to destination as well as vehicle or tank status. Therefore, we propose a safety monitoring system for tank lorry to check driving condition and the vehicle status. We studied the integration of central control system with in-vehicle computer system connected with various sensors for monitoring through a communication network.

  • PDF

Predicting and Preventing Damages from Gas Leaks at LPG Stations (LPG 충전소의 가스누출에 따른 피해예측 및 감소방안)

  • YANG-HO YANG;HA-SUNG KONG
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.577-585
    • /
    • 2023
  • This study applied ALOHA Program to predict the damage caused by fire and explosion predicted to occur from gas leakage at LPG stations and presented plans to prevent damages by diagramming the impact range and distance. The propane gas leakage from LPG stations causes human damage like breathing issues and property damage, including building destruction to residents in the surrounding areas. As a way to reduce this, first, the hazardous substance safety manager of the LPG station needs to check frequently whether the meters and safety valves are working properly to prevent leakage in advance. Second, the LPG stations' storage tanks should be worked by the person who received "hazardous substance safety manager training" under the provisions of the Act on the Safety Control of Hazardous Substances and has been appointed as a "hazardous substance safety manager" by the fire department. Third, LPG station's various safety device functions, such as overfill prevention devices, must be checked on a regular basis. Finally, wearing work clothes and shoes that prevent static electricity at LPG stations is highly recommended, as static can cause a fire when gas leaks.