• Title/Summary/Keyword: Gas pressure

Search Result 6,661, Processing Time 0.034 seconds

Kinetics of the Reaction of Carbon Dioxide with AMP and Piperazine (AMP에 Piperazine을 첨가한 CO2 흡수 동역학)

  • Jang, Sang-Yong;Song, Ju-Seouk;Cho, Sang-Won;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.485-494
    • /
    • 2000
  • According to the worldwide interest in controlling $CO_2$ which contributes to green house effect. new techniques of reducing $CO_2$ are under development. We have developed new technique for reducing $CO_2$. In low $CO_2$ concentration. the chemical absorption method is useful. In this study. the kinetics of the reaction between $CO_2$ and the sterically hindered amine solution with piperazine. have been investigated from measurements of the rate of absorption of $CO_2$ in the stirred vessel that has a horizontal liquid-gas interface, in the temperature range $30{\sim}70^{\circ}C$. The experiments were carried out in the range 10.130~20.260 kPa of partial pressure of $CO_2$, and in aqueous $2.0kmol/m^3$ AMP solution with $0{\sim}0.4kmol/m^3$ piperazine The experimental results are as follows: 1) The absorption rate of $CO_2$ into aqueous AMP + piperazine solution is gett ng faster than that of aqueous AMP absorbents with temperature. Because the activation energy of piperazine 57.147 kJ/mol is higher than that of AMP 41.7kJ/mol. therefore the effect of piperazine on absorption rate increases with temperature. 2) Compared with aqueous AMP solution. the absorption rate of $CO_2$ into AMP + piperazine solution increases from 6.33% at $30^{\circ}C$ to 12% at $70^{\circ}C$, so AMP + piperazine solution is thought to be a better than AMP solution, 3) The reaction rate constants of piprazine in aqueous AMP solution with $CO_2$ have been determined as 217.21, 420.46, 707.00 and $3162.167m^3/kmol{\cdot}s$ respectively at 30, 40, 50 and $70^{\circ}C$ but these results are higher than those of Xu which were 186.7. 367.32. 693.01. $2207.65m^3/kmol{\cdot}s$ at 30, 40, 55, $70^{\circ}C$in aqueous MDEA solution. So the regression analysis of the data has led to the following equation In $k_p$ =28.324-6934.7/T.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Estimation of surface nitrogen dioxide mixing ratio in Seoul using the OMI satellite data (OMI 위성자료를 활용한 서울 지표 이산화질소 혼합비 추정 연구)

  • Kim, Daewon;Hong, Hyunkee;Choi, Wonei;Park, Junsung;Yang, Jiwon;Ryu, Jaeyong;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.2
    • /
    • pp.135-147
    • /
    • 2017
  • We, for the first time, estimated daily and monthly surface nitrogen dioxide ($NO_2$) volume mixing ratio (VMR) using three regression models with $NO_2$ tropospheric vertical column density (OMIT-rop $NO_2$ VCD) data obtained from Ozone Monitoring Instrument (OMI) in Seoul in South Korea at OMI overpass time (13:45 local time). First linear regression model (M1) is a linear regression equation between OMI-Trop $NO_2$ VCD and in situ $NO_2$ VMR, whereas second linear regression model (M2) incorporates boundary layer height (BLH), temperature, and pressure obtained from Atmospheric Infrared Sounder (AIRS) and OMI-Trop $NO_2$ VCD. Last models (M3M & M3D) are a multiple linear regression equations which include OMI-Trop $NO_2$ VCD, BLH and various meteorological data. In this study, we determined three types of regression models for the training period between 2009 and 2011, and the performance of those regression models was evaluated via comparison with the surface $NO_2$ VMR data obtained from in situ measurements (in situ $NO_2$ VMR) in 2012. The monthly mean surface $NO_2$ VMRs estimated by M3M showed good agreements with those of in situ measurements(avg. R = 0.77). In terms of the daily (13:45LT) $NO_2$ estimation, the highest correlations were found between the daily surface $NO_2$ VMRs estimated by M3D and in-situ $NO_2$ VMRs (avg. R = 0.55). The estimated surface $NO_2$ VMRs by three modelstend to be underestimated. We also discussed the performance of these empirical modelsfor surface $NO_2$ VMR estimation with respect to otherstatistical data such asroot mean square error (RMSE), mean bias, mean absolute error (MAE), and percent difference. This present study shows a possibility of estimating surface $NO_2$ VMR using the satellite measurement.

Factors Related to the Development of Myocardial Ischemia During Mechanical Ventilation (인공 호흡기 적용에 따른 심근 허혈의 발생에 관한 연구)

  • Kim, Tae-Hyung;Kim, You-Ho;Lim, Chae-Man;Kim, Won;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.645-653
    • /
    • 1999
  • Introduction : Although myocardial ischemia tends to occur more frequently than can he documented in ventilated patients, it has not been well studied on the factors related to the occurrence of the ischemia. Methods : To investigate the related factors to ischemia development, a prospective study was done in 95 cases with consecutive 73 patients who had received mechanical ventilation(MV) in MICU. In addition to 24 h holter monitoring, echocardiogram, electrolytes, cardiac enzymes, hemodynamic, and gas exchange measurements were done within 24 h after initiation of MV in 69 cases. The measurements were repeated at weaning period in 26 cases. The ischemia was defined by the ST segment changes; up-sloping depression more than 1.5 mm or down-sloping or horizontal depression more than 1.0 mm from isoelectric baseline for 80 ms following J point. Results : Twelve patients(12.6% in 95 cases) developed ischemia in total. The incidence of ischemia development showed an increased tendency in the initial 24 hr after MV (15.9%) and in patients with left-sided heart failure found by echocardiogram (18.2%) compared with that of the weaning period (3.8%) and patients without heart failure (10.9%) (P=0.12, P=0.09, in each). There were no differences in APACHE III score, baseline ECG findings, electrolytes abnormalities, use of inotropics or bronchodilators, presence of sepsis or shock, mode of ventilation, and survival rate according to the development of ischemia. Maximal heart rates and mean arterial pressure also were not different between patients with ($137.2{\pm}30.9/min$, $82.5{\pm}15.9$ mm Hg) and without ischemia ($l29.5{\pm}29.7/min$, $83.8{\pm}17.6$ mm Hg). Conclusion : Although the incidence of myocardial ischemia was 12.6% in total, there were no clinically predictable factors to the development of ischemia during mechanical ventilation.

  • PDF

Optimization of particle gun-mediated transformation system in Cymbidium (유전자총을 이용한 형질전환 심비디움 식물체 생산체계 최적화)

  • Noh, Hee-Sun;Kim, Mi-Seon;Lee, Yu-Mi;Lee, Yi-Rae;Lee, Sang-Il;Kim, Jong-Bo
    • Journal of Plant Biotechnology
    • /
    • v.38 no.4
    • /
    • pp.293-300
    • /
    • 2011
  • This study is conducted to develop an efficient transformation system via particle bombardment with PLBs (Protocorm-like bodies) in Cymbidium. For this, pCAMBIA3301 vector which carries a herbicide-resistant bar gene and gus gene as a reporter gene was used for transformation with Cymbidium cultivars 'Youngflower ${\times}$ masako' line. To select transformants, proper concentration of herbicide, PPT (phosphinotricin), should be determined. As a result, 5 mg/l of PPT was selected as a proper concentration. Further, proper conditions for particle bombardment were determined to obtain a high frequency of transformation. Results showed that 1.0 ${\mu}g$ of DNA concentration, 1,100 and 1,350 psi for helium gas pressure, 1.0 ${\mu}m$ of gold particle and 6 cm of target distance showed the best result for the particle bombardment experiment. Also, pre-treatment with combination 0.2 M sorbitol and 0.2 M mannitol for 4 hrs prior to genetic transformation increased the transformation efficiency up to 2.5 times. Using transformation system developed in this study, 3.2 ~ 4.0 transgenic cymbidium plants can be produced from 100 bombarded PLBs on average. Putative transgenic plants produced in this system confirmed the presence of the bar gene by PCR analysis. Also, leaves from randomely selected five transgenic lines were applied for Basta solution (0.5% v/v) to check the resistance to the PPT herbicide. As a result, three of them showed resistance and one of them showed the strongest resistance with the maintenance of green color as non-transformed plants showed. Using this established transformation system, more genes of interests can be introduced into Cymbidium plants by genetic transformation in the future.

Effect of Oil Extraction Methods on Sterol Composition of Sesame Oil (채유방법(採油方法)이 참기름의 Sterol조성(組成)에 미치는 영향(影響))

  • Choi, Sang-Do;Kim, Hyoung-Kab
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.14 no.4
    • /
    • pp.365-369
    • /
    • 1985
  • In order to examine the effect of oil extraction methods on the characteristics of sesame oil, the unsaponifiable matters, fractionation sterol pattern and sterol compositions of the each fraction of the oil were compared in the oil extracted by the three different extraction methods, that is, pressure extraction of roasted seed (RTP), acetone extraction of roasted seed(RTE) and acetone extraction of raw seed(RWE). The amount of unsaponifiable in RWE oil was silghly higher as 31.8mg per 1mg drying oil than that in RTP oil of 26.1mg. Sesame oils from three different extraction methods were found to contain $0.26{\sim}0.32%$ free, $0.23{\sim}0.42%$ bound, and $0.49{\sim}0.64%$ total sterol. The content of free sterol in RWE oil was higher as 0.32% than that in RTE and RTP oil of 0.26%, and that of sterylglycoside in RTE oil was lower as 0.12% than that in RTP and RWE oil of 0.23%, but that of sterylester was a little difference. The unsaponifiable matter from fractionation sterol in sesame oil by three different extraction methods was fractionated into less polor compounds, 4,4-dimethyl-, 4-monomethyl-, 4-desmethylsterol fraction by thinlayer chromatography, and sterol composition of 4-desmethylsterol fraction was analyzed by gas liquid chromatography. The major sterols were campe-, stigma-, sito-, and ${\Delta}^5-avenasterol$, but, specially, unknown sterol(RRT:1.35) was found as $23.5{\sim}26.4%$ in total sterols, The content of sitosterol, ${\Delta}^5-avenasterol$, campesterol and stigmasterol were $59.9{\sim}60.3%,\;8.1{\sim}11%,\;16.1{\sim}18.4%,\;11.6{\sim}12.8%$ of the total sterol in free sterol fraction, $37.3{\sim}46.9,\;11.6{\sim}14.2,\;6.6{\sim}9.0$, and $6.1{\sim}8.0%$ of the total sterol in sterylglycoside fraction, $55.9{\sim}59.9,\;9.2{\sim}11.4,\;17.1{\sim}18.9$, and $11.8{\sim}13.7%$ of the total sterol in sterylester fraction, and $39.3{\sim}42.9,\;13.0{\sim}17.2,\;9.1{\sim}11.0$ and $7.4{\sim}11.5%$ of the total sterol in total sterol fraction. But the effect of oil extraction methods on sterol composition in sesame oil were hardly found.

  • PDF

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

Morphological Characteristics of Seed Coat and Enzyme Activity of Aleurone Layers in Soybeans (콩 종피의 형태적 특성과 호분층 세포의 효소활성 연구)

  • 박정화;김용욱
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.33 no.2
    • /
    • pp.112-121
    • /
    • 1988
  • Soybean seed coat consisted of three layers, and the aleurone layer was attached to the innermost part of seed coat. It showed the different morphological characteristics with single cell layer compared with many cell layers in barley aleurone layer. The structural difference in aleurone cell among varieties was not detected in this experiment. The hole of middle part of hilum consisted of net formed material in order to pass water and gas. In the experiment, it was not studied whether the varieties with hard seed consist of the same structure or not, but the detailed study on this would be necessary. The activity of acid phosphatase showed a tendency to increase in process of imbibition in distilled water. There was no significant difference in the enzyme activity among the varieties tested, but the enzyme activity of Danyoupkong was slightly higher than that of Hwanggeumkong. In germinability, Danyoupkong is higher than Hwangkeumkong, so it might be attributed to the higher activity. There was no difference in acid phosphatase activity between released from the aleurone cell and accumulated in the aleurone cell from 6 to 12 hours incubation of the medium in the absence of GA$_3$, but the difference was detected after 12 hours incubation. And enzyme activity was the highest in the 18 hours incubation. The increase in the release of acid phosphatase from the aleurone cell would be considered as passive diffusive effect due to the increase in turgo pressure of aleurone cell. The acid phosphatase released from aleurone layer increased greatly after 24 hours incubation of the medium in the presence of GA$_3$ and the accumulation within the aleurone cell decreased linearly after 18 hours incubation. The result indicates that GA$_3$ enhance the rate of enzyme release from aleurone layer, suggests that the aleurone cell wall be digested by the introduction of GA and the digested wall act as the channels for enzyme release.

  • PDF

Effect of Sunlight, Incandescent, Fluorescent, and Ultraviolet Lights on the Oxidation of Edible Soybean Oil (식용유지(食用油脂)의 산화과정(酸化過程)에 대한 일사광선(日射光線), 백열등광선(白熱燈光線), 형광등광선(螢光燈光線) 및 살균등광선(殺菌燈光線)의 촉진작용(促進作俑) 대하여)

  • Koo, Ja-Hyun;Kim, Dong-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.178-184
    • /
    • 1971
  • Samples of refined soybean oil were irradiated with lights from a 20-watt incandescent tungsten lamp, a 20-watt fluorescent daylight type lamp, a 20-watt low-pressure mercury vapor germicidal lamp, and direct sunlight for an experimental period of 147 days. Some samples were stored in a dark room throughout the period as a control. The peroxide values of all samples were measured every week. The induction period of the samples was arbitrarily taken as the time required for the samples to reach a peroxide value of 15. The induction period of the control was estimated at 198 days. Those of the samples irradiated with the incandescent light, the fluorescent light, the ultraviolet light, and the sunlight were estimated at 196, 119, 52 and 6 days, respectively. The sunlight showed by far the strongest prooxidant activity whereas the incandescent light showed the weakest but distinct prooxidant activity. The small temperature differences observed among the various samples throughout the experimental period did not seem to affect the oxidation rates of the irradiated samples in any significant way.

  • PDF

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.