• 제목/요약/키워드: Gas insulation

검색결과 539건 처리시간 0.025초

건물 외피 투과형단열 벽체의 열성능 해석 연구 (Thermal Performance of Building Envelope with Transparent Insulation Wall)

  • 장용성;윤용진;박효순
    • KIEAE Journal
    • /
    • 제5권1호
    • /
    • pp.27-33
    • /
    • 2005
  • Global efforts have made to reduce energy consumption and $CO_2$ gas emission. One of the weakest parts for energy loss through the whole building components is building envelopes. Lots of technologies to increase the thermal performance of building envelopes have been introduced in recent year. Transparent Insulation Wall(TIW) is a new technology for building insulation and has been function both solar transmittance and thermal insulation. A mathematical model of a Transparent Insulation Wall equipped with south wall was proposed in order to predict thermal performance under varying climates(summer and winter). Unsteady state heat transfer equations were set up using an energy balance equation and solved using Gauss-Seidel iteration solution procedure. The thermal performance of the TIW determined from a wall surface and air layer temperature, non-airconditioned room temperature and air conditioning load. As a result, this numerical study shows that the TIW is effective in an air conditioning load reduction. Further experimental study is required to establish complete TIW system.

초고압 XLPE 전력케이블의 절연특성평가(I) (Evaluation of Insulation Characteristics of EHV XLPE Power Cable)

  • 정광희;백인재;이인호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1617-1619
    • /
    • 1998
  • In the nation, 154kV XLPE cable with an insulation thickness of 23mm have been used for transmission lines. The thickness is designed by old parameters which were determined by Kreuger, Oudin et al. in 1960s. By the way, the manufacturing technology has been developed. Especially in extruding and curing process we are using a triple common extruding head and applying gas-curing process. It allows the quality of XLPE cable improved. The paper evaluates the AC minimum insulation breakdown strength of XLPE power cable using model table. We can verify the uplifted insulation quality. And we expects the cable insulation thickness to be reduced applying the new parameter to the cable insulation design.

  • PDF

LNG 벙커링용 이중 단열적용 LNG 저장탱크 열해석 (Thermal Analysis on the LNG Storage Tank of LNG Bunkering System Applied with Double Shield Insulation Method)

  • 정일영;김남국;윤상국
    • 한국가스학회지
    • /
    • 제22권4호
    • /
    • pp.1-6
    • /
    • 2018
  • IMO에서 규정하는 LNG 벙커링 선박용 연료 탱크 중 C형 가압탱크는 내외 2중 용기로 구성된 초저온 탱크에 $10^{-2}$ Torr 진공과 펄라이트 단열재가 충전되는 것이다. 그러나 이 단열방식은 LNG 기화량이 하루당 2.0 % 내외로 증발율이 커서 보다 단열효과가 좋은 탱크가 요구되어 진다. 본 연구에서는 내외탱크 사이에 고진공을 적용하고 외부탱크의 내벽체에 중간 단열로 펄라이트 진공단열을 적용하는 단열 방식을 새로이 고안하여 열해석을 수행하였다. 이의 장점으로는 진공 공간의 감소로 고진공 형성 시간을 크게 감소되고, 진공도 $10^{-4}$ Torr 이하에서 하루당 증발율이 0.16 %에 불과한 매우 효율이 높은 탱크 단열방식이 되었다. 만약 현재의 IMO C형 탱크의 진공펄라이트 단열에서 진공이 파괴되는 경우, C형 탱크는 하루당 4.9 %의 증발이 발생하고 새 고안 탱크는 5.23 %로 거의 동일하게 된다.

가스터빈 발전기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in Gas Turbine Generator Stator Windings)

  • 김희동;양규현;주영호
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1423-1428
    • /
    • 2010
  • The results of off-line and on-line diagnostic tests performed on the stator winding of an air-cooled gas turbine(G/T) generator are reported in this paper. Off-line diagnostic tests included measurements of the ac current, dissipation factor(tan${\delta}$), and partial discharge(PD). Six epoxy-mica capacitors were installed in the three phases of G/T generator for performing on-line diagnostic testing with the turbine generator analyzer(TGA). The TGA showed that the normalized quantity number(NQN) and the PD magnitude($Q_m$) were high in phase A of the stator winding. Internal discharges were generated in phases B and C, and slot discharge occurred in phase A. According to the trend analyses of the NQN and $Q_m$ values available for insulation condition assessment for G/T generator stator windings, it was concluded that phases B and C were in good condition, whereas phase A has been significantly deteriorated.

FEM을 이용한 음향신호의 전달특성에 관한 연구 (Investigation on propagation characteristics of AE signal with FEM)

  • 서판석;구경완;김종석;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study. conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as $SF_6$, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But. when the breakdown in the electric insulation occurs. it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And. in general. UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis. we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

FEM을 이용한 음향신호의 전달특성에 관한 연구 (Investigation on propagation characteristics of AE signal with FEM)

  • 서판석;구경완;김종석;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study, conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as SF6, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But, when the breakdown in the electric insulation occurs, it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And, in general, UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis, we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

금속 이물질이 에폭시 절연물의 절연파괴에 미치는 영향 (Effects of Metal Particle on Dielectric Breakdown of Epoxy Insulation)

  • 장윤기;이동원;김정배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.207-208
    • /
    • 2007
  • Epoxy resin insulators show a lot of advantages for electrical power apparatus. Because epoxy resin provide electrical and mechanical characteristic which is excellent, it is desirable to apply epoxy resin as a spacer and post insulation in Gas Insulated Switchgear (GIS). In this study, we have investigated the influence of surface electric field attached particle contaminated spacer surfaces under SF6 gas. Also, we performed analysis of electric field. As a result, when the particle was attached on spacer, we found out a surface electric field of characteristics.

  • PDF

Type C 연료탱크에 적용되는 분말형 단열 소재의 상온/극저온 기계적 특성에 관한 연구 (A Study of Mechanical Characteristics at Room/Cryogenic Temperature of Powder Insulation Materials Applied to Type C Fuel Tank)

  • 김태욱;오재원;서영균;한성종;이제명
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.787-793
    • /
    • 2021
  • The global demand for Liquefied Natural Gas(LNG) continues to increase and is facing a big cycle. To keep pace with the increase in international demand for LNG, the demand for LNG fueled ships is also increasing. Since LNG fuel tanks are operated in a cryogenic environment, insulation technology is very important, and although there are various types of insulation applied to Type C tanks, multi-layer insulation and vacuum insulation are typically applied. Powder insulation materials are widely used for storage and transportation of cryogenic liquids in tanks with such a complex insulation structure. In this study, compression tests at room and cryogenic temperature were performed on closed perlite, glass bubble, and fumed silica, which are representative powder insulation material candidates. Finally, the applicability to the Type C fuel tank was reviewed by analyzing the experimental results of this study.

LMG 배관시스템의 열유동 해석 및 최적설계 프로그램 개발 (A Computer Programme Development for Thermal-Hydraulic Analysis and Optimal Design on LNG Pipeline System)

  • 이상규;홍성호;이중남;박석호
    • 한국가스학회지
    • /
    • 제4권2호
    • /
    • pp.7-14
    • /
    • 2000
  • 생산지로부터 LNG 선박으로 수송되어 각 생산기지의 저장탱크로 저장되는 액화천연가스 (LNG; Liquified Natural Gas)는 극저은인 Boiling Point보다 약간 낮은 온도 ($-162^{\circ}C$)로 전송된다. LNG 전송은 배관을 통하여 이루어지며, 이로 인하여 배관 내에는 2상 유동 (2-Phase Flow)이 자주 형성된다. 본 연구에서는 일차적으로 이러한 배관내의 2상 유동대한 압력강하량 계산법을 연구하였고, 단열재와 배관 표면을 통한 외부 열유입량과 그에 따른 BOG (Boil-off Gas) 발생량 계산 방법을 연구하여, 이들을 기반으로 LNG 배관시스템의 열유동 해석 프로그램을 개발하였다. 또한 본 연구 및 프로그램 개발을 토대로 최적의 단열재 두께와 배관 Size를 구할 수 있는 최적 설계 프로그램을 구축하였다. 이는 배관설계 시 주어진 최대 허용 압력 강하량과 BOG 발생량 등의 허용 운전 조건과, 단위 길이 당 배관가격과 단위 부피당 단열재가격을 기준으로 허용 범위 내의 최소 설비 비용을 찾는 최적 설계 방법이다.

  • PDF

Prediction of Insulation Capability for Ground Fault to Consider Asymmetry in SF6 Circuit Breaker

  • Oh, Yeon-Ho;Song, Ki-Dong;Kim, Hong-Kyu;Lee, Hae June;Hahn, Sung-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2046-2051
    • /
    • 2015
  • Currently, most high-voltage gas circuit breakers (CBs) include asymmetrical geometries in the shield, the tank, the hot-gas exhaust, and the connection parts for bushings. For this reason, a 3-dimensional (3-D) analysis of the insulation capability is necessary, rather than a 2-D analysis. However, a 3-D analysis has difficulties due to the computational time and complex modeling. This paper presents a 3-D analysis considering the asymmetry in high-voltage gas CBs and a technique to reduce the calculation time. In the proposed technique, the arc plasma requiring the most computational time is first calculated by a 2-D analysis. Then, the results such as pressure, temperature, and velocity are input as a source for the 3-D analysis. This technique is applied to a 145kV self-blast-type CB and the analysis result exhibits good agreement with the experimental result.