• Title/Summary/Keyword: Gas heating

Search Result 1,222, Processing Time 0.031 seconds

An Experimental Study on the Effects of Operating Variables on the Cooling and Heating Performance of Geothermal Heat Pump (지열 히트펌프에서 운전변수가 냉난방 성능에 미치는 영향에 대한 실험연구)

  • Chang, Keun-Sun;Kang, Hee-Jeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.562-570
    • /
    • 2011
  • In this research, an experimental study is performed to investigate the effects of system operating variables on the cooling and heating characteristics of heat pump system using geothermal heat source and carbon dioxide as a refrigerant. System variables analyzed include compressor frequency, electronic expansion valve opening, refrigerant charge, secondary fluid temperature and flow rate. Results show that optimum refrigerant charge and electronic expansion valve opening position exist at the maximum point of COP curve, and both cooling and heating capacity increase but COPs decrease with the increase of compressor frequency. The change of a secondary fluid temperature leads to variation of overheat area and enthalpy difference in the evaporator and gas cooler. which again results in considerable variations of cooling and heating capacity and COP. In the case of effects of secondary water fluid flow rate, both cooling capacity and COP increase with the increase of secondary flow in evaporator or gas cooler, whereas heating capacity and COP decrease with the increase of flow rate in gas cooler.

Performance Variation of a Combined Cycle Power Plant by Coolant Pre-cooling and Fuel Pre-heating (냉각공기 예냉각과 연료예열에 의한 복합발전 시스템의 성능변화)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kim, Tong-Seop;Kim, Jae-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.57-63
    • /
    • 2012
  • Effects of coolant pre-cooling and fuel pre-heating on the performance of a combined cycle using a F-class gas turbine were investigated. Coolant pre-cooling results in an increase of power output but a decrease in efficiency. Performance variation due to the fuel pre-heating depends on the location of the heat source for the pre-heating in the bottoming cycle (heat recovery steam generator). It was demonstrated that a careful selection of the heat source location would enhance efficiency with a minimal power penalty. The effect of combining the coolant pre-cooling and fuel pre-heating was also investigated. It was found that a favorable combination would yield power augmentation, while efficiency remains close to the reference value.

A Study on the Mechanical Properties of Heated Plates by Induction Heating System (고주파 유도가열된 조선용 강판의 기계적 특성 연구)

  • Hyun, Chung Min;Yi, Myung Su;Cho, Si Hoon;Jang, Tae Won
    • Journal of Welding and Joining
    • /
    • v.32 no.1
    • /
    • pp.47-52
    • /
    • 2014
  • Due to of high intensity, lower noise and easy controllability of the heat, induction heating system became well known. Induction heating method has been suggested as substitute for the gas heat source and adopted in the automation of curved hull forming system. In this study, an investigation was accomplished to find the effects on the change of material properties when the induction heating was applied on the mild steel plate. Plates were heated using weaving method to get sufficiently heat affected zone and then cooled with water or in the air. The mechanical properties of the heated plate were evaluated. As results, the tensile test, impact test and microstructures satisfied the class rule.

Thermodynamic Analysis on the Feasibility of Turbo Expander Power Generation Using Natural Gas Waste Pressure (천연가스 폐압발전 활성화의 당위성에 대한 열역학적 분석)

  • Ha, Jong Man;Hong, Seongho;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.136-142
    • /
    • 2012
  • Thermodynamic equations for the electric power and temperature in a turbo expander generator (TEG) using pressure energy in a natural gas line are derived. From the equations, it was shown that dominant factor is not the pressure difference but the pressure ratio. The high energy level in the inlet of TEG can be made from nearly no expense of electric energy input, which means TEG can be treated as one of newly available clean energy source. If a post heating method is chosen to heat up expanded natural gas, the usage of cold energy is possible without a refrigeration cycle. The combined TEG and refrigeration system enhances economic benefit much more.

Thermal Losses Due to Non-ideal Gas Behavior of Helium in VM Heat Pumps (헬륨의 비이상기체 거동에 따른 VM열펌프의 손실)

  • Baik, J.H.;Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.279-287
    • /
    • 1996
  • A cycle analysis is performed to investigate how the non-ideal gas behavior of helium reduces the heating capacity of VM heat pumps. Since the operating pressures of VM heat pumps are as high as 1 to 20 MPa, the compressibility factor of helium becomes clearly greater than 1 and the non-ideal behavior always represents a thermal loss in heating. To calculate the amount of the losses, an adiabatic cycle analysis is performed with the real properties of helium and the net enthaply flows through the two regenerators are numerically obtained. It is shown that the non-ideal gas losses could be as much as 8% in the heating capacity when the operating pressures are greater than 10MPa. The effects of the operating temperatures and the dead volumes on the loss are presented.

  • PDF

A Study on Annealing Cycle Control Temperature of Hi - CON/2 BAF and HNx BAF (Hi-CON/H2 BAF와 HNx BAF의 소둔사이클 제어온도에 관한 연구)

  • 김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.114-122
    • /
    • 1994
  • A cold temperature control system for the BAF(batch annealing furnace) has been established in order to reduce energy consumption to imrpove productivity and stabilize the properties of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, changing annealing cycle time according to BAF temperature with time during heating and actual temperature measurements cold spot during soaking. The results of the temperature variation effect on the batch annealing are as follows. 1) Cooling rate is increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component. Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas and annealing cycle time is reduce to 2.7 times. 2) With enlarging the difference between furnace temperature and soaking temperature at the HNx BAF, heating time becomes short, but cooling time is indifferent. 3) If temperature difference of 300.deg. C in the temperature change of cold spot according to the annealing cycle control temperature, Hi-CON/H2BAF is interchanging at each other at 26hours, but HNxBAF at 50 hours. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1219 mm width coil must be 2.5 hours longer then that of 914mm width coil for the same coil weight at Hi-CON/H2BAF. But, it is necessary to make 2 hours longer at HNxBAF.

  • PDF

Comparative studies of gasification potential of agro-waste with wood and their characterization

  • Tripathi, Amarmani;Shukla, S.K.
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.181-194
    • /
    • 2015
  • In this work, an experimental study of the gasification on wood was carried out in downdraft type fixed bed Gasifier attached with 10 kW duel fuel diesel engine. The main objective of the study was to use wood as the biomass fuel for downdraft Gasifier and to evaluate the operating parameter of gasifier unit to predict its performance in terms of gas yield and cold gas efficiency. The influence of different biomass on fuel consumption rate, gas yield and cold gas efficiency was studied. Composition of producer gas was also detected for measuring the lower heating value of producer gas to select the feed stock so that optimum performance in the existing gasifier unit can be achieved. Under the experimental conditions, Lower heating value, of producer gas, cold gas efficiency and gas yields, using wood as a feed stock, are $4.85MJ/m^3$, 46.57% and $0.519m^3/kg$.

Correlations between the Important Physical Properties of Natural Gas (천연가스 주요 물성 간의 상관식)

  • Ha, Youngcheol;Lee, Seongmin;Her, Jaeyoung;Lee, Kangjin;Lee, Seungjun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.599-607
    • /
    • 2009
  • This study was conducted to derive the five correlations which could predict specific gravity(or heating value), compression factor, density, etc., if we know heating value or specific gravity only. To make a sufficient number of raw data for regression, SGERG EOS was modified into equation of heating value. Based on these raw data, five correlations were obtained and the uncertainties of the correlations were evaluated. The results showed that the uncertainties were near 0.1% in most conditions of natural gas and so the correlations could be used in natural gas industry and academic fields.

Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building (오피스텔 모델건물의 생애주기비용 분석에 의한 다층유리창 경제성 비교)

  • Jung Gun-Joo
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.101-109
    • /
    • 2006
  • The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.

Thermal and Dynamical Evolution of a Gaseous Medium and Star Formation in Disk Galaxies

  • Kim, Chang-Goo;Kim, Woong-Tae;Ostriker, Eve C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.54.1-54.1
    • /
    • 2011
  • Formation of self-gravitating gas clouds and hence stars in galaxies is a consequence of both thermal and dynamical evolution of a gaseous medium. Using hydrodynamics simulations including cooling and heating explicitly, we follow simultaneously thermal and dynamical evolution of galactic gas disks to study dynamics and structures of galactic spiral shocks with thermal instability and regulation of the star formation rates (SFRs). We first perform one-dimensional simulations in direction perpendicular to spiral arms. The multiphase gas flows across the arm soon achieve a quasi-steady state characterized by transitions from warm to cold phases at the shock and from cold to warm phases in the postshock expansion zone, producing a substantial fraction of intermediate-temperature gas. Next, we allow a vertical degree of freedom to model vertically stratified disks. The shock front experiences unsteady flapping motions, driving a significant amount of random gas motions, and self-gravity promotes formation of bound clouds inside spiral arms. Finally, we include the star formation feedback in both mechanical (due to supernova explosion) and radiative (due to FUV heating by young stars) forms in the absence of spiral arms. At saturation, gravitationally bound clouds form via thermal and gravitational instabilities, which are compensated by disruption via supernova explosions. We find that the FUV heating regulates the SFRs when gas surface density is low, confirming the prediction of the thermal and dynamical equilibrium model of Ostriker et al. (2010) for star formation regulation.

  • PDF