• Title/Summary/Keyword: Gas generator

Search Result 757, Processing Time 0.026 seconds

A Study on the Development of After Burner in Inert Gas Generator (비활성 가스 제네레이터의 후방연소기 개발에 관한 연구)

  • Kim, H.K.;Ahn, K.Y.;Kim, H.S.;Lim, I.G.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.909-914
    • /
    • 2001
  • After burner which is main part of inert gas generator(IGG) is studied for the development of IGG. The results of many experimental equations are applied to estimate characteristics of the spray nozzle and evaporation of spray, and selected the optimum design point of after burner. The selected design point of after burner are validated experimentally through the pilot plant of after burner. The flame stability is favorable at design point(150mm), that distance from stabilizer to nozzle. The emission of $NO_x$ and CO is lower than gas turbine combustor which was used in primary combustor.

  • PDF

Effect of Distilled Water Supply Method on Performance of PEMWE Typed Hydrogen Generators for Inhalation (흡입용 PEMWE형 수소 발생기에서 증류수 공급 방법이 성능에 미치는 영향)

  • In-Soo, You;Hyunwoo, Bae;Joon Hyun, Kim;Jaeyong, Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.117-127
    • /
    • 2022
  • The present study has investigated the performance of hydrogen gas generators for inhalation purposes based on polyelectrolyte membrane water electrolysis (PEMWE). The system applied two watering methods. One is pumped water (pumping system) and the other is gravity-fed water without a pump (non-pumping system). The cell efficiencies were compared by measuring the cell voltage and temperature in the hydrogen gas generator, respectively. The results show that the cell voltage and temperature increase with the cell current. The cell temperature is lower in the pumping system than that in the non-pumping system at a given cell current. Even though the amount of hydrogen production is the same regardless of the pumping system, the cell efficiency of the hydrogen gas generator in the non-pumping system is better than that in the pumping system.

Experimental Study on Thermal Insulation and Cooling for Rotor/Bearing Area in 500W Class Micro Gas Turbine Generator (500W급 마이크로 가스터빈 발전기 회전체-베어링부의 단열 및 냉각 성능에 대한 실험적 연구)

  • Park, Cheol Hoon;Choi, Sang Kyu;Ham, Sang Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.19-24
    • /
    • 2014
  • Development of long-term mobile energy sources for mobile robots or small-sized unmanned vehicles are actively increasing. The micro gas turbine generator (MTG) is a good candidate for this purpose because it has both of high energy density and high power density, and 500W class MTG is under development. The designed MTG can be divided into 2 main parts. One part consists of motor/ generator and compressor, and the other one consists of combustor, recuperator and turbine. 500W class MTG is designed to operate at ultra-high speed of 400,000 rpm in high turbine temperature over $700^{\circ}C$ to improve the efficiency. Because the magnetism of NdFeB permanent magnet for the motor/generator could be degraded if the temperature is over $150-200^{\circ}C$, MTG needs the thermal insulation to block the heat transfer from combustor/turbine side to motor/generator side. Moreover, the motor/generator is allocated to get the cooling effect from the rapid air flow by the compressor. This study presents the experimental results to verify whether the thermal insulator and air flow are effective enough to keep the motor/generator part in the low temperature less than $100^{\circ}C$. From the motoring test by using the high temperature test rig, it was confirmed that the motor/generator part could maintain the temperature less than $50^{\circ}C$ under the condition of 1.0 bar compressed air.

A Study on V-I Characteristics of Hydrogen-Oxygen Gas Generator

  • Yang Seung-Heun;Kang Byoung-Hee;Gho Jae-Soek;Mok Hyung-Soo;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.109-112
    • /
    • 2001
  • Water-Electrolyzed gas is a mixed gas of the constant volume ratio 2:1 of Hydrogen and Oxygen gained from electrolyzed water, and it has better characteristics in the field of economy, efficiency of energy, and environmental intimacy than acetylene gas and LPG (Liquefied Petroleum Gas) used for existing gas welding equipment. So studies of Water-Electrolyzed gas are activity in progress nowaday, and commercially used as a source of thermal energy for gas welding in the industry. The object of this paper is getting a V-I characteristic of Hydrogen-Oxygen Gas Generator using DC source. First, chemical analysis of electrolysis is conducted and the relation of electrical energy and then chemical energy is investigated through the faraday's laws.

  • PDF

Combustion Chamber Development for Suppression of Combustion Instability in a Gas Generator at a Liquid Rocket Engine (액체로켓엔진용 가스발생기에서 연소불안정 방지를 위한 연소실 개발)

  • Ahn Kyu-Bok;Lee Kwang-Jin;Lim Byoung-Jik;Han Yeoung-Min;Choi Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.207-210
    • /
    • 2005
  • The results of combustion performance test of fuel-rich gas generator with dual swirl injectors are described. By changing simulating duct and recess number(RN) of the injectors, we inspected whether the combustion instability took place. When the injectors of RN = 0.5 were used, combustion instabilities could be reduced using the simulating duct. However, the effect of the simulating duct on the gas generator with the injectors of RN = 1.5 was not significant.

  • PDF

Structural Analysis of a Gas Generator Oxidizer Shut-Off Valve (가스발생기 산화제 개폐밸브 구조 해석)

  • Ryoo, Seung-Hun;Hong, Moon-Geun;Yoo, Jae-Han;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.413-416
    • /
    • 2009
  • For the liquid rocket engine, the gas generator oxidizer shut-off valve which supplies the oxidizer to a gas generator needs structural safety under the internal pressure, which is higher than the chamber pressure. In this study, static stress analyses of the various design in the vicinity of the region where the stress is concentrated were performed for designing the lightweight valve, A lightest model of which the concentrated stress does not exceed the yield criteria has been suggested. Also, whole size effect of the valve on the concentrated stress was investigated.

  • PDF

Hot-firing Test Results of Subscale Gas Generator for 75 ton-class Liquid Rocket Engine (75톤급 액체로켓엔진 축소형 가스발생기 연소시험 결과)

  • Kim, Mun-Ki;Ahn, Kyu-Bok;Lim, Byoung-Jik;Kim, Jong-Gyu;Seo, Seong-Hyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.726-728
    • /
    • 2010
  • A subscale gas generator was designed and manufactured to investigate the effect of design parameters on discharge coefficients of injectors for a 75 ton-class gas generator and hot-firing tests were successfully performed. The test results showed that discharge coefficients of fuel and liquid oxygen injectors remained nearly constant irrespective of variations of a mixture ratio and a chamber pressure. When the post diameter of the liquid oxygen injector was reduced, the discharge coefficient was increased as the pressure drop of the injector was decreased.

  • PDF

Control law design of gas generator for secondary combustion (이차 연소를 위한 가스발생기의 압력 제어기법 연구)

  • Park, Ik-Soo;Lee, Jae-Yoon;Choi, Ho-Jin;Yoon, Hyun-Gull;Lim, Jin-Shik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.565-568
    • /
    • 2010
  • A pressure control law to regulate mass flow rate of gas generator is suggested. The governing equation is modeled by considering the burning rate of solid propellant and the conservation equation of gas generator. And then, a classical control law is applied after verifying the accuracy of dynamic model through comparing with ground test and internal ballistic results. The results show degradation of performance as shown in typical time varying system. To overcome this problem, an adaptive scheme is suggested and the performance is verified through numerical simulation.

  • PDF

Hot-firing Tests of Subscale Gas Generator for 75 ton-class Liquid Rocket Engine (75톤급 액체로켓엔진 축소형 가스발생기 연소시험)

  • Kim, Mun-Ki;Seo, Seong-Hyeon;Ahn, Kyu-Bok;Lim, Byoung-Jik;Kim, Jong-Gyu;Lee, Kwang-Jin;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.173-176
    • /
    • 2010
  • A subscale gas generator was designed and manufactured to understand a reason for increased pressure drop of liquid oxygen injectors observed in a technology demonstration model of a 75 ton-class gas generator. A total of 6 hot-firing tests were successfully performed including experimental conditions of design and off-design points. The hot-firing results showed that discharge coefficients of fuel and liquid oxygen remained constant as the mixture ratio varied at a fixed chamber pressure. At a fixed mixture ratio, it was also found that discharge coefficients of fuel and liquid oxygen was constant as the chamber pressure was increased.

  • PDF

Analysis of Dynamic Pressure Characteristics for Startup of KSLV-II 75 tonf Class Liquid Rocket Engine (한국형발사체 75톤 엔진의 시동 시 동압 특성 분석)

  • Moon, Yoonwan;Jung, Eunhwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1084-1087
    • /
    • 2017
  • When a liquid rocket engine is started the oxidizer and fuel must be flowed into combustion chamber and gas generator with time differences. The wrong time difference between propellants or malfunction of ignition device can occur the explosion of combustion chamber due to detonation by energized premixed-propellants. Therefore it is important to observe the transient characteristic of propellants or to measure the inflow time of propellants into combustion chamber and gas generator. The measurement of static pressure is not enough to observe the propellants inflow time into combustion chamber and gas generator. By measuring dynamic pressure of main flow passage of propellants the accurate propellants inflow time could be investigated.

  • PDF