• Title/Summary/Keyword: Gas discharge lamp

검색결과 81건 처리시간 0.028초

Discharge characteristics of a Flat Fluorescent Lamp(FFL) contanining Penning gases

  • Lee, Sang-Mok;Cho, Yong;Jung, Sang-Kooun;Jeong, Byoung-Hyun;Jeong, Yun-Cheol;Kwak, Min-Gi;Sohn, Sang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.675-678
    • /
    • 2006
  • We developed a Flat Fluorescent Lamp(FFL) with a high luminance by using the same discharge mode as PDP. Our FFL has the simple and unique structure where the glass substrates are used as dielectric layers. The panel has a striped line shape of 7 inch diagonal size. The Xe-Ne-He mixture gas was used to generate the plasma, and the gas discharge characteristics under both total gas pressure and partial gas pressure were investigated. The panel showed a maximum high luminance $7,270cd/m^2$ under bias of 20KHz pulse of 3KV.

  • PDF

환경개선용 기체전기방전을 이용한 오존발생기술 개발 (Development of Ozone Generation Technology Using Gaseous Electrical Discharge for Environment Improvement)

  • 이동헌;송현직;구건효
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.25-34
    • /
    • 2001
  • 본 논문에서는 방전관을 채용하여 전기적 기체방전의 중침을 이용한 새로운 방전형식의 환경개선용 오존발생 기술을 개발하였다. 방전관형 오존발생기(DLO)는 설치된 3개의 전극중 접지전극인 중심전극으로 방전관을 사용 하였으며, 나머지 2개의 메쉬형 내부전극과 나선형 외부전극에 180[$^{\circ}$]의 위상차를 가진 2개의 교류고전압 전원을 인가함으로써 방전관과 내부전극, 방전관과 외부전극사이의 방전공간에서 각각 발생되는 무성방전의 중침에 의하여 오존이 발생되는 구조이다. 이때, 원료가스의 유량, 방전전력 및 DLO의 사용 개수 변화에 따른 방전특성과 오존생성특성을 연구검토하였으며, DLO로부터 생성된 오존을 대기오염물질인 NO 가스에 접촉시켰을 때 NO 제거특성이 우수하여 방전관형 오존발생기가 대기환경개선 설비로 적용가능함을 확인하였다.

  • PDF

평판형 광원에서 제논(Xe) 플라즈마의 전기적 광학적 특성 연구 (The electrical and optical properties of Xe plasma in flat lamp)

  • 백광현;양종경;이종찬;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.60-64
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important, distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp, we tested the discharge from 100 Torr to 300 Torr pressure, the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

무전극 황방전등에서 고압 이원자 황($S_2$)의 자체 역전 효과 (Self Reversal Effect of the High-pressured Diatomic Sulfur in the Electrodeless Sulfur Discharge Lamp)

  • 추장희;구선근;박기준;이영우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권11호
    • /
    • pp.609-615
    • /
    • 2000
  • A prototype electrodeless sulfur lamp was developed and investigated the spectroscopic characteristics. The emission spectra of $S_2$ in the microwave-discharged eletrodeless sulfur lamp (ESL) were studied at various input power. The emission spectra of the ESL shift to longer wavelength with increasing of the input power. We have shown that this is due to the self reversal effect in the high pressure gas discharge. We also show that the self reversal effect increases as the rotation of the discharged bulb. The spectral distribution of the ESL shifts about 45 nm toward visible region from UV region due to the rotation of the lamp bulb.

  • PDF

정전탐침법을 사용한 평판형 광원의 제논(Xe)플라즈마 특성 연구 (Xe Plasma property with flat lamp by Langmuir probe)

  • 백광현;양종경;이종찬;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.572-573
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness. life time. efficiency of flat lamp and plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. When a distance of discharge electrode is 5.5mm and width is 16.5mm. we measured electron temperature and electron density measured with single Langmuir probe in flat lamp. We tested the discharge from 100 Torr to 300 Torr pressure. The pulse type was rectangular with frequency 20kHz and duty ratio was 20%. In result. electron temperature decreases and electron density increased as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Ne, Ar, Kr 혼합가스에서의 유도결합형 플라즈마 방전특성 (Inductively Coupled Plasma discharge characteristic of Ne, Ar, Kr mixed gas)

  • 허인성;최용성;이종찬;정영일;박대희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.9-12
    • /
    • 2004
  • Recently, the environmental problem has received considerable attention. so, many lamps have been developing for environmental requirement and energy efficiency. also, at glow discharge lamp researchers try to reduce energy spending that is power saving lamp. this kind requirement agree with strong points of electrodeless fluorescent lamp has received to now lighting sauce. At low pressure as mTorr I.C.P make high density plasma easily, is good to maintain discharge, has high ionization and does not have failing lighting and losing ability of electron radiation by oxidation and volatilization of electrodes, because this tape does not have electrodes This point of I.C.P can use at electrodeless fluorescent lamp in this study ICP display elements and Ar, Ne, Kr are researched for optical characteristic. each gas is looked into optical characteristic, also mixed gases is experiment for optical characteristic.

  • PDF

Emission Characteristics of Flat Fluorescent Lamp for LCD Backlight Using Inert Gas Mixture

  • Heo, Sung-Taek;Lee, Yang-Kyu;Kang, Jong-Hyun;Yoon, Seung-Il;Oh, Myung-Hoon;Lee, Dong-Gu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1522-1525
    • /
    • 2007
  • In this study, flat fluorescent lamps (FFLs) having surface discharge structures was fabricated by screen printing technique and were studied using spectraradiometer and square pulse power supply. Two types of FFLs having different shapes of electrodes (crosstype and line-type structure) were compared with variation of discharge shape and mixed gas ratio.

  • PDF

개선된 램프형 오존발생기에 관한 연구 (A Study on the Improved Lamp Ttpe Ozonizer(ILO))

  • 페이즐 라만;이상근;전병준;송현직;이광식;이동인
    • 조명전기설비학회논문지
    • /
    • 제13권3호
    • /
    • pp.109-117
    • /
    • 1999
  • 본 논문에서는 환경개선 및 건강증긴 설비로써 활용되고 있는 Ultraviolet(U.V.) 광화학 반응을 이용한 lamp 형 오존발생기(LO)의 특성을 개선할 목적으로 LO에 연면방전을 중첩시킨 개선된 형태의 오존발생기(ILO)를 설계.제작하였다. 제작된 오존발생기는 전압인가 방식에 따라서 2가지 형태의 오존발생기 (LO 및 ILO)가 구성되고, 이들 각 오존발생기에 대하여 전력, 원료가스의유량에 따른 오존생성농도, 오존발생량 및 오존생성수율특성을 연구 검토하였다. 이때, 오존생성온도, 오존발생량 및 오존생성수율 등 ILO가 LO보다 우수한 것으로 나타나서, LO의 오존생성특성을 향상시킬수 있었다. 그 결과, 방전전력이 19[W]로 일정한 경우 ILO가 LO보다 오존생성논도,오존발생량 및 오존생성수율의 원료가스의 유량이 $1[\ell/min]$일 때 124[%], $6[\ell/min]$일 때 143[%]상승하였으며 본 연구에서는 712[ppm]의 오존생성농도, 128[mg/h]의 오존발생량과 6750[mg/kwh]의 오존생성수율을 얻을 수 있다.

  • PDF

고출력 무전극램프의 가스압 및 아말감종류에 따른 특성분석 및 최적화에 관한 연구 (Study of the Characteristic and Optimization of Induction Lamp according to Gas Pressure and Amalgam Type)

  • 정영일;정대철;김용갑;박대희
    • 한국정보전자통신기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.23-30
    • /
    • 2017
  • 현재는 도로조명의 경우 기존 메탈할라이드 램프 400W이하로 설치되어 있어 에너지절약형 조명으로 대체가 이루어지고 있으며, 무전극 램프는 터널조명과 고천정조명 적용분야를 타겟으로 더욱 활발한 교체가 이루어질 것으로 예상된다. 따라서 추가적으로 고효율, 고출력 무전극 램프 시스템 개발이 필요한 상황이다. 본 연구에서는 고출력 무전극 램프의 설계 및 제작을 진행하여 가스종류 및 가스압에 따른 비교 분석, 아말감 종류에 따른 특성 분석 등을 통한 무전극 램프 최적화를 진행하였다. 현재 고출력 무전극 램프 방전관 및 페라이트코어에 맞는 가스압 300~350[mmHg] 사이로 최적화 하였다. 인듐(In) 아말감을 적용한 무전극 램프로 점등회로 매칭을 완료하여 250W(정격${\pm}10%$)로 정격소비전력으로 최적화를 완료하였다.

LCD 백라이트용 면방전형 FFL의 방전 특성 (Discharge Characteristics of Surface Discharge Type FFL for LCD Backlighting)

  • 임민수;윤성현;신유섭;정득영;권순석;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1786-1788
    • /
    • 1999
  • In this paper, we studied Surface Discharge Type Flat Fluorescent Lamp with High Luminance for LCD Backlighting, Liquid Crystal display(LCDs) demand the use of fluorescent lamp as the backlighting source. This lamp is Surface Discharge Type structure with a pair of Sodalime glass, insulator layer, phosphor layer, and Xe gas gap. In spite of its simple structure, the lamp has uniform and stable discharge over entire volume. Till now, we measured the current-voltage(V-I), Firing Voltage, Sustain Voltage for 0.5mm, 1mm electrode gap. In experiment result, long gap cell structure cause high firing voltage. The rising in firing voltage in long gap structure could not be explained by paschen's law because of non-uniform electric field.

  • PDF