자외선/적외선 불꽃감지기 소개 및 오동작 방지를 위한 연구 (Introduction of Ultraviolet/Infrared Flame Detector and Method for False Detection Prevention)

  • 임병현;고낙용;황종선;김영민;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.8-11
    • /
    • 2003
  • We propose that when combustible burn with contain carbon, introduce fire detector with sensor of private-use detectable light energy as infrared and ultraviolet in energy of electromagnetic-wave type radiate from flame, method for correct discrimination to resemble fire produce false alarm of detector such as sun light, hot object radiation, are welding. This research using infrared sensor is pyroelectric infrared sensor based black body radiation theory. Ultraviolet sensor is uv Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV/IR compound type flame detector and proposed method of false alarm reduced to resemble fire. The result propres the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

인화성 가스를 취급하는 반도체 제조장비에 설치된 가스박스 최적 환기 설계에 대한 연구 (A Study on Optimal Ventilation Design for Gas Boxes Installed in Semiconductor Manufacturing Equipment Handling Flammable Liquids)

  • 조규선;김상령;양원백
    • 한국가스학회지
    • /
    • 제27권1호
    • /
    • pp.63-69
    • /
    • 2023
  • 대한민국은 세계 1위의 반도체 생산 국가임에도 불구하고 산업 보호를 위한 현장의 폐쇄성으로 대부분의 연구가 단순한 물질 위험에 대한 위험성평가로 이루어지고 있다. 산업 안전 측면에서 유해위험물질의 누출 상태를 파악하는 가스 감지기 등의 모니터링 시스템 등을 구축하고 있으나, 누출 시 유해위염 물질을 효과적으로 배기하기 위한 연구는 최근에서야 시작되었다. 인화성 물질이 다량 취급되는 반도체 제조설비(가스박스)는 현재 가스 감지기 및 공기투입구를 막는 방법으로 안전관리를 하고 있는데, 공기투입구가 없으면 박스 내부를 음압으로 관리할 수는 있으나 내부 기류가 원활히 생성되지 않아 인화성 물질 누출 시 단시간 희석이 어렵다. 따라서 본 연구에서는 여러 기준들을 기본으로 하여 가스박스 규모에 따른 덕트 사이즈의 결정, 공기 투입구의 적정크기 연구를 통하여 인화성 누출 시 유해화학물질이 외부로 노출되지 않으면서 배기 성능 요구량을 최소로 할 수 있는 최적 배기 설계를 해보고자 한다.

플라즈마진동을 이용한 기체크로마토그래프의 검출기에 대한 연구 (Study on the Plasma Oscillation for Gas Chromatographic detector)

  • 김효진;맹대영;강종성
    • 분석과학
    • /
    • 제6권4호
    • /
    • pp.369-374
    • /
    • 1993
  • 플라즈마 진동 현상은 글로우방전을 이용한 기체크로마토그래프 검출기의 개발 과정에서 측정되었으며 전류의 변화에 비하여 매우 안정하며 낮은 검출한계로 새로운 검출기로의 개발 가능성이 높다. 플라즈마 진동의 최적 조건과 메카니즘을 규명하기 위하여 몇 가지 실험조건을 변화시키며 관찰하였다. 즉, 방전전압(전류), 압력, 그리고 방전전극 간격을 변화시킨 결과 다양한 형태의 진동이 10KHz에서 10MHz까지의 주파수 범위에서 관찰되었다. 특히 방전전극 간격에 따라 낮은 압력과 전압의 조건에서 두 가지 형태의 진동이 나타났다. 한 가지 형태는 positive column 영역에서, 또 다른 하나는 negative glow 영역에서 측정되었다. Positive column 영역보다 negative glow 영역에서 발생된 플라즈마 진동이 훨씬 더 높은 감도 변화와 더 큰 주파수를 보였다.

  • PDF

3-5 $\mu m$ 적외선 흡수체를 가진 전면 건식 식각된 서모파일과 NDIR $CO_2$ 가스 센서의 응용 (A Front-side Dry-Etched Thermopile Detector with 3-5 $\mu m$ Infrared Absorber and Its Application to Novel NDIR $CO_2$ Gas Sensors)

  • 유금표;김시동;최우석;;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1470-1471
    • /
    • 2008
  • We present a front-side micromachined thermopile with high sensitivity in the 3-5${\mu}m$ window, and discuss its application to a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. The micromachined thermopile shows a measured sensitivity of 30 mV/W and a $D^*$ of $0.3{\times}10^8cm^{\surd}Hz/W$. Using this newly fabricated thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

글로우 방전을 이용한 기체크로마토그라피 검출기 (A Gas Chromatographic Detector using Glow Discharge)

  • 한종수;송승호
    • 대한화학회지
    • /
    • 제35권4호
    • /
    • pp.350-354
    • /
    • 1991
  • 헬리움 흐름에서 글로우 방전을 이원화원으로 사용한 기체 크로마토그라피의 검출기 특성을 연구하였다. 방전전극 사이의 거리가 1 mm 일 때, 400 V/mm 의 전장의 세기 이상에서 10$_6$A 이상의 방전전류가 관찰되었다. 유기물의 검출에는 0.1~0.3 mA의 방전전류가 적당하였다. 순수한 헬리움의 흐름에서는 10 ml/min 이상의 유속에서 방전전류가 거의 일정하였으나, 0~30 ml/min 의 유속에서는 적은양의 유기물의 주입에 의해 방전이 쉽게 사라졌다. 여러 화합물에 따른 방전전류의 감소로부터 글로우 방전 이온화 기체크로마토그라피 검출기의 감도는 그 화합물의 분자량에 크게 영향받음을 알았다.

  • PDF

Effect of Bile Salt on the Pharmacokinetics of Bretylium in the Rat (I) - Increased Lipophiiicity of Bretylium by Ion-Pair Complexation with Taurodeoxycholate -

  • Shim, Chang-Koo;Chung, Suk-Jae;Lee, Jeong-Uk;Lee, Min-Hwa;Kim, Shin-Keun
    • Archives of Pharmacal Research
    • /
    • 제9권2호
    • /
    • pp.111-114
    • /
    • 1986
  • Bretylium tosylate is a quaternary ammonium compound used for the treatment of ventricular fibrilation in humans. It is advantageous to other cationic compound in the study of biliary excretion in that negligible amount is bound to plasma protein and metabolite is not likely is to be formed. Some researchers reported that the formation of ion-pair complex caused to increase the lipothilicity of cationic compound. The partition of bretylium between water and organic phase was increased with the addition of sodium taurodeoxycholate. Also sensitive gas chromatographical assay procedure using flame ionization detector was studied. This procedure can detect as low as 0.1 mg/ml using 0.1 ml biological sample, but contamination by previous injection is the major problem of this method.

  • PDF

건축물내 일산화탄소 경보기 설치에 관한 연구 (A Study on Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석;오정석
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2008년도 춘계학술 발표회
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

Multi-Pesticide Residue Method for Analysis of Organochlorine and Organophosphorus Pesticide

  • Bonghun Lee;Woo
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 1997년도 가을 학술발표회 프로그램
    • /
    • pp.37-39
    • /
    • 1997
  • Pesticide residues were extracted with 70% acetone and transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil and alumina-N, The final extract was analyzed by gas chromatography with electron-capture detector(GC/ECD) and nitrogen-phosphorus detector(GC/NPD). Recoveries of the 17 organochlorine pesticides were ranged from 60.8 to 84.9% and those of 15 organophosphorus pesticides, from 70.5 to 100.0%(except phosmet and azinphos-methyl). The minimum detectable levels of this analytical method were low (0.021-0.058 mg/kg).

  • PDF

우리나라 하수 및 폐수 처리 슬러지의 유기인계 살충제의 함량 (Contemporary Organic Contamination Levels in Digested Sewage Sludge from Treatment Plants in Korea : (3) Organophosphorus Insecticides)

  • 홍기훈;이강영;정창수;이현경
    • 한국환경과학회지
    • /
    • 제15권3호
    • /
    • pp.229-236
    • /
    • 2006
  • Organophosphorus pesticides (OPPs) contents in the sewage sludge derived from the residential and industrial areas were determined in order to characterize contemporary organic contamination levels as a part of the ongoing development of the environmentally sound sewage sludge management strategy in Korea. OPPs were extracted from freeze-dried sludges in a ultrasonic extractor. The extracts were cleaned-up by florisil column and subsequently fed into gas chromatograph/nitrogen phosphorus detector (GC/NPD) for determining OPP contents. Diazinon, dimethoate, disulfoton, EPN, malathion, methyl parathion, parathion, phorate and sulfotep were present in the appreciable amount in the domestic sewage sludges. The sum of the 9 OPPs in the sewage sludge varied from 534.8 to 15552.1 ${\mu}g/kg$, dry wt..

유기인제 농약 분석 방법 (Multi-Pesticide Residue Method) 개발에 관한 연구 (Study on the Development of Analytical Method (Multi-Pesticide Residue Method) for Organophosphate Pesticides)

  • 이봉헌;김우성
    • 한국환경과학회지
    • /
    • 제6권2호
    • /
    • pp.183-187
    • /
    • 1997
  • 유기인제 농약을 70% acetone으로 추출한 다음 dlchloromethane 층으로 옮겨 추출물을 florisil로 충진된 open-column에서 chromatography를 행하였다. 마지막 추출물을 nitrogen-phosphorus detector(GC/NPD)을 가진 GC로 분석하였다. Narrow-bore capillary GC(Ultra-2)에 대해 18 가지의 유기인제 농약의 회수율이 88.7%에서 100.0%에 달하였다. 본 분석 방법의 최소 검출 준위는 0.019 - 0.035 mg/kg 이었으며 sample throughput(추출, open-column chro-matography 및 GC 분석)도 상당히 개선되었다.(sample당 8시간)

  • PDF