• Title/Summary/Keyword: Gas analyzer

Search Result 483, Processing Time 0.031 seconds

Development of Automatic Data Transmitting System of Arterial Blood Gas Results via Local Area Network( LAN) (LAN을 이용한 혈액가스 검사결과 전송시스템)

  • 김남현;김원기
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.327-332
    • /
    • 1993
  • Automatic transmission of data from the blood analyzer to the request site is one of the most important part in hospital computerization. We have developed a system that transmits data from the arterial blood gas analyzer to the request site automatically In this system HOST computer, FILE server,'LAN(Local Area Network) , 3270 Emulator and bfulti-port card are integrated with 3 blood gas analyzers(NOVA Inc., USA) which are connected to a single multi-port card in a personal computer. When specimen are collected from tramp)inly sites, they are transferee to the laboratory In the Yonsei Cardiovascular Center After analysis, the result is transmitted to the personal computer via serial commnunication between machine and multi-port card using interrupt method. Then, the patient's information (Name, Patient ID No., etc.) is obtained from the HOST computer througth the emulator. The combined data (patient information & lab data) is transmitted to each request site via LAN automatically These results are stored in the File Server for one year and they can be reviewed anytime. Also, it could be used for the various statistics and the flow chart for clinical research. Additionally, we found thal this system reduces the personal labor.

  • PDF

Measurement of Ion Energy Distribution using QMS & Ionization Enhancement by usign Magnetic Field in Triod BARE (자장을 이용한 이온화율 증대형 삼극형 BARE에서 이온화율의 증대경향과 QMS를 이용한 이온의 에너지 분포 측정)

  • 김익현;주정훈;한봉희
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.3
    • /
    • pp.119-124
    • /
    • 1991
  • Recently, the trend of research in hard coating is concentrate on developing the process of ionization rate under low operating pressure, to get the thin film with high adhesion and dense microstructures. In this study ionization rate enhancement type PVD process using permanent magnet is developed, which enhances the ionization rate by confining the plasma suppressing the wall loss of electron. By the result to investigate the characteristic of glow discharge, the ionization rate of this process is enhanced about twice as high as that of triod BARE process (about 26%), and more dense TiN microstructures are obtained in this process. Cylindrical ion energy analyzer is made and attached in front of a quadrupole mass filter for the analysis of the energy distribution of reactive gas and activated gas ions from the plasma zone. To analyze the operation mechanism of ion energy analyzer, computer simulation is performed by calculation the electric field environment using finite element method. By these analyses of ion energy distribution of outcoming ions from the plasma zone, it is found that magnetic field enhances ion kinetic energy as well as ionization rate. The other results of this study is that the foundation of feed-back system is constructed, which automatically control the partial pressure of reactive gas. In can be possible by recording the data of mass spectrum and ion energy analysis using A-D converter.

  • PDF

Development of Emission Factors for Greenhouse Gas CO2) from Anthracite Fired Power Plants in Korea (무연탄 화력발전소의 이산화탄소 배출계수 개발)

  • Jeon, Eui-Chan;Myeong, Soo-Jeong;Jeong, Jae-Hak;Lee, Sung-Ho;Sa, Jae-Whan;Roh, Gi-Hwan;Kim, Ki-Hyun;Bae, Wi-Sup
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.440-448
    • /
    • 2007
  • Although the anthracite power plant is an important source of greenhouse gas, research on this type of power plant has not been conducted much. The present study investigated the entire anthracite power plants in Korea and analyzed the emitted gas in connection with GC/FD and a methanizer in order to develop $CO_2$ emission factors. The study also sampled the anthracite to analyze the amount of carbon and hydrogen using an element analyzer, and to measure the calorie using an automatic calorie analyzer. The emission factors computed through the fuel analysis was 30.45 kg/GJ and that computed through the $CO_2$ gas analysis was 26.48 kg/GJ. The former is approximately about 15% higher than the latter. When compared the carbon content factors of anthracite with that of bituminous coal, the value of anthracite was 24% higher Compared with IPCC values, the emission factors by the fuel was 14% higher, and that by the emitted $CO_2$ gas was about 1.2% lower. More research is needed on our own emission factors of various energy-consuming facilities in order to stand on a higher position in international negotiations regarding the treaties on climate changes.

Comparison of the bovine blood gas parameters produced with three types of portable blood gas analyzers

  • Ro, Younghye;Choi, Woojae;Hong, Leegon;Kim, Eunkyung;Choe, Eunhui;Kim, Danil
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.60.1-60.6
    • /
    • 2022
  • Background: A definite diagnosis should be made in the bovine practice field, however, it was difficult to perform laboratory analysis immediately. Currently, three types of portable blood gas analyzers are available in Korea. Objectives: This study aimed to evaluate the correlations among these three analyzers. Methods: Seventy-two plasma samples from Holstein-Friesian cows were used for blood gas analysis, and three instruments (EDAN i15 Vet, VETSCAN i-STAT, and EPOC) were operated simultaneously. Moreover, plasma calcium levels were compared between these portable analyzers and blood chemistry device, which is usually used in a laboratory environment. Pearson analysis was performed to confirm the correlation of each parameter produced with the three instruments and blood chemistry analyzer. Results: As results, high correlation was observed in parameters of pH, pO2, potassium ion, ionized calcium, and glucose (p < 0.001, r > 0.7). In addition, pCO2 showed a moderate correlation among the three analyzers (p < 0.001, r > 0.5), and there was no correlation among all instruments for sodium ions. There was also a high correlation between ionized calcium from the three portable devices and total calcium from the biochemistry analyzer (p < 0.001, r > 0.9). Conclusions: In conclusion, there was a high correlation between results from the three different blood gas analyzers used in the bovine clinical field in Korea. Thus, a consistent diagnosis can be made even with different equipment if the operator is aware of the strengths and weaknesses of each piece of equipment and operates it properly.

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF

Surface Acoustic Wave Gas Sensor (탄성표면파 가스센서)

  • Yoo, Beom-Keun;Park, Yong-Wook;Kang, Chong-Yun;Kim, Jin-Sang;Choi, Doo-Jin;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.251-252
    • /
    • 2006
  • A development of surface acoustic wave gas sensor to detecting volatile gas has been observed by monitoring output signal as function of time onto the network analyzer. The SAW sensor with a center frequency of 200MHz was fabricated on $42^{\circ}$ S-T Quartz substrates. Using the gas chromatography column has been selectivity. Experimental results, which show the phase change of output signal under the absorption of volatile gas onto sensors, were presented. The proposed sensor has the properties of high sensitivity compare to the conventional SAW gas sensor and chemical selectivity. Thus, it is thought these results are applicable for use in sensor array of an high performance electronic nose system.

  • PDF

A study on the Development of Purge Burner for City Gas (도시가스용 퍼지 버너 개발에 관한 연구(II))

  • Lee, Hyun-Chan;You, Hyun-Seok;Lee, Joong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.175-179
    • /
    • 2000
  • A combustion project was completed regarding the development of a high-flow-rate purge burner in cooperation with three city gas companies(Pusan, Taegu, Samchulli). The project, started in May 1991, aimed at purging the line-packed-gas safely and quickly before getting into gas pipe working or relocation. According to the results, the purging noise is less than 80dB due to silencer screen. multi-nozzle and outlet inserted tube employed. In addition, the developed burner shows an increased work efficiency of 40-50% more as compared to the performance of conventional purge equipments. The project result is regarded as the first high-flow-rate purge burner developed within Korea. contributing to shortening purge hours, safe field work and easiness of purge site selection.

  • PDF

Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

Plasma Facing Material 흡착기체의 정량적 분석을 위한 Thermal Desorption Analyzer (TDA) 개념 설계

  • Kim, Hui-Su;On, Yeon-Gil;Lee, Seok-Gwan;Choe, Min-Sik;No, Seung-Jeong;Gwon, Jin-Jung;Park, Jun-Gyu;Lee, Cheol-Ui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.513-513
    • /
    • 2012
  • 핵 융합로의 대면재질(Plasma Facing Material; PFM)은 고온의 플라즈마와 고 에너지의 이온들에 지속적으로 노출 된다. 특히 PFM은 흡착되는 기체 등에 의한 부식과 변형이 발생할 수 있다. 현재 핵 융합로 내부의 PFM으로 고려되고 있는 재질 중 하나인 고순도 탄소타일의 경우 고온의 수소동위원소 플라즈마에 직접적으로 노출되므로 이에 의한 탄소타일에 흡착되는 수소 등의 기체에 대한 정량적인 분석방법이 필요하다. 본 연구는 고순도 탄소타일 등과 같은 플라즈마 대면재료에 흡착되어 있는 물질의 정량적 분석이 가능한 TDA (Thermal Desorption Analyzer)의 개념 설계에 관한 것이다. TDA는 고온 가열($800^{\circ}C$ 이상) 및 시료 장착부 및 초고진공(~10-9 torr) 및 측정부의 두 부분으로 구성 하였다. TDA 설계시 고온 가열 및 시료 장착부는 시료 내부에 흡착되어 있는 기체의 효과적 탈착을 위한 가열 및 시료의 모양에 영향을 받지 않는 장착방법, 시료 장착부의 outgassing rate를 최소화 하는 재질 선정 등을 고려하였으며, 초고진공(~10-9 torr) 및 측정부는 초고진공 유지방법, 터보펌프 배기속도 실측을 위한 구조, 진공측정 ion 게이지, 잔류가스분석기(Residual Gas Analyzer)의 최적위치 설정 등을 고려하여 설계하였다. 개념 설계된 TDA에 대하여 발표하고자 한다.

  • PDF

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.