• Title/Summary/Keyword: Gas analyzer

Search Result 484, Processing Time 0.028 seconds

Differences of Lumbar Muscle Activity and Oxygen Consumption According to Bike Saddle Height (자전거 안장높이에 따른 요추부 근 활성도 및 산소 소모량 차이)

  • Choi, Wonjae;Lee, Choongho;Jung, Jihye;Lee, Seungwon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.363-369
    • /
    • 2018
  • The purpose of this study was to investigate the differences of lumbar muscle activity (LMA) and oxygen consumption (OC) according to bike saddle height in healthy young men. Twenty-two subjects without musculoskeletal disorders participated in this study. Subjects performed 3 min cycling at 3 different saddle heights with 10 minutes of resting time respectively. Surface EMG was used to assess muscle activity in LMA, and OC was assessed by potable gas analyzer. In the result, there was a statistically significant difference in internal oblique abdominis activity (p<0.05), and the OC was significantly higher in high saddle height than the optimal and the low position of the saddle (p<0.05). This study suggest that changes in saddle height affected internal oblique abdominis activity and OC in subjects, however, saddle height does not have much effect on lumbar stabilizer muscle.

Improvement of Mass Spectral Detection Performance by Pre-correction of Peak Position Error (피크위치오차 사전 보정을 통한 질량 스펙트럼 검출 성능 개선)

  • Lee, Young Hawk;Heo, Gyeongyong;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.666-674
    • /
    • 2019
  • In the mass spectrum of the mass spectrometer, the spectrum of the low peak adjacent to the spectrum having the high peak value is connected to each other and thus the separation is difficult. This inter-spectral overlap causes degradation of the mass spectral detection performance and resolution. In this paper, we propose a method to improve the mass spectrum detection performance and peak accuracy of residual gas analyzer. The type discrimination according to the characteristics of the ion signal block and the pre-correction for the peak position error can separate and detect the spectrum of the low peak connected to the adjacent spectra. To verify the performance of the proposed method, we compared the proposed method with the conventional method in simulations using actual ion signals obtained from the mass spectrometer under development.

Effect of pyrolysis temperature and pressing load on the densification of amorphous silicon carbide block (열분해 온도와 성형압력의 영향에 따른 비정질 탄화규소 블록의 치밀화)

  • Joo, Young Jun;Joo, Sang Hyun;Cho, Kwang Youn
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.6
    • /
    • pp.271-276
    • /
    • 2020
  • In this study, an amorphous SiC block was manufactured using polycarbosilane (PCS), an organosilicon polymer. The dense SiC blocks were easily fabricated in various shapes via pyrolysis at 1100℃, 1200℃, 1300℃, 1400℃ after manufacturing a PCS molded body using cured PCS powder. Physical and chemical properties were analyzed using a thermogravimetric analyzer (TGA), scanning electron microscope (SEM), energy dispersive spectroscopy (EDS), and universal testing machine (UTM). The prepared SiC block was decomposed into SiO and CO gas as the temperature increased, and β-SiC crystal grains were grown in an amorphous structure. In addition, the density and flexural strength were the highest at 1.9038 g/㎤ and 6.189 MPa of SiC prepared at 1100℃. The manufactured amorphous silicon carbide block is expected to be applicable to other fields, such as the previously reported microwave assisted heating element.

Experimental Study on the Characteristics of Microbubbles Generated by an Effervescent Tablet in Water (수중 내 발포성 정제로부터 생성된 미세기포 특성에 관한 실험적 연구)

  • Myeong, Jaewon;Maeng, Juyoung;Kim, Young Jun;Cho, Kyungmin;Lee, Woonghee;Kim, Sungho;Park, Youngchul;Sohn, Youngku;Shin, Weon Gyu
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.84-91
    • /
    • 2021
  • Effervescent tablets generate gas bubbles when chemical reaction occurs between water and tablets. Most of previous studies have been focused on pharmaceutical characteristics of tablets. However, for their applications in disinfectants, cleaners, and pesticides, physical characteristics of bubbles released from the effervescent tablets when they are in water are important. In this study, we experimentally investigated the characteristics of microbubbles generated by an effervescent tablet made of sodium bicarbonate and tartaric acid using PDPA and high-speed camera. Microbubbles were generated using different weights of effervescent tablet as well as in different water temperature. The experimental study shows increase in reaction time, bubble concentration and rise velocity as the weight of effervescent tablet increases from 1 to 20 g. The decrease in average bubble diameter was observed when the temperature of water increased from 25 to 45 ℃. Further, reaction time varies inversely with increase in water temperature, while bubble rise velocity is directly proportional to increase in water temperature. Effervescent table continuously generates the bubble with approximately constant diameter (235 ㎛) in the water. However, bubble concentration and bubble rise velocity decreased over time.

Predicting the resting metabolic rate of young and middle-aged healthy Korean adults: A preliminary study

  • Park, Hun-Young;Jung, Won-Sang;Hwang, Hyejung;Kim, Sung-Woo;Kim, Jisu;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.24 no.1
    • /
    • pp.9-13
    • /
    • 2020
  • [Purpose] This preliminary study aimed to develop a regression model to estimate the resting metabolic rate (RMR) of young and middle-aged Koreans using various easy-to-measure dependent variables. [Methods] The RMR and the dependent variables for its estimation (e.g. age, height, body mass index, fat-free mass; FFM, fat mass, % body fat, systolic blood pressure, diastolic blood pressure, mean arterial pressure, pulse pressure, and resting heart rate) were measured in 53 young (male n = 18, female n = 16) and middle-aged (male n = 5, female n = 14) healthy adults. Statistical analysis was performed to develop an RMR estimation regression model using the stepwise regression method. [Results] We confirmed that FFM and age were important variables in both the regression models based on the regression coefficients. Mean explanatory power of RMR1 regression models estimated only by FFM was 66.7% (R2) and 66.0% (adjusted R2), while mean standard errors of estimates (SEE) was 219.85 kcal/day. Additionally, mean explanatory power of RMR2 regression models developed by FFM and age were 70.0% (R2) and 68.8% (adjusted R2), while the mean SEE was 210.64 kcal/day. There was no significant difference between the measured RMR by the canopy method using a metabolic gas analyzer and the predicted RMR by RMR1 and RMR2 equations. [Conclusion] This preliminary study developed a regression model to estimate the RMR of young and middle-age healthy Koreans. The regression model was as follows: RMR1 = 24.383 × FFM + 634.310, RMR2 = 23.691 × FFM - 5.745 × age + 852.341.

Prediction of non-exercise activity thermogenesis (NEAT) using multiple linear regression in healthy Korean adults: a preliminary study

  • Jung, Won-Sang;Park, Hun-Young;Kim, Sung-Woo;Kim, Jisu;Hwang, Hyejung;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.1
    • /
    • pp.23-29
    • /
    • 2021
  • [Purpose] This preliminary study aimed to develop a regression model to estimate the non-exercise activity thermogenesis (NEAT) of Korean adults using various easy-to-measure dependent variables. [Methods] NEAT was measured in 71 healthy adults (male n = 29; female n = 42). Statistical analysis was performed to develop a NEAT estimation regression model using the stepwise regression method. [Results] We confirmed that ageA, weightB, heart rate (HR)_averageC, weight × HR_averageD, weight × HR_sumE, systolic blood pressure (SBP) × HR_restF, fat mass ÷ height2G, gender × HR_averageH, and gender × weight × HR_sumI were important variables in various NEAT activity regression models. There was no significant difference between the measured NEAT values obtained using a metabolic gas analyzer and the predicted NEAT. [Conclusion] This preliminary study developed a regression model to estimate the NEAT in healthy Korean adults. The regression model was as follows: sitting = 1.431 - 0.013 × (A) + 0.00014 × (D) - 0.00005 × (F) + 0.006 × (H); leg jiggling = 1.102 - 0.011 × (A) + 0.013 × (B) + 0.005 × (H); standing = 1.713 - 0.013 × (A) + 0.0000017 × (I); 4.5 km/h walking = 0.864 + 0.035 × (B) + 0.0000041 × (E); 6.0 km/h walking = 4.029 - 0.024 × (C) + 0.00071 × (D); climbing up 1 stair = 1.308 - 0.016 × (A) + 0.00035 × (D) - 0.000085 × (F) - 0.098 × (G); and climbing up 2 stairs = 1.442 - 0.023 × (A) - 0.000093 × (F) - 0.121 × (G) + 0.0000624 × (E).

Estimating excess post-exercise oxygen consumption using multiple linear regression in healthy Korean adults: a pilot study

  • Jung, Won-Sang;Park, Hun-Young;Kim, Sung-Woo;Kim, Jisu;Hwang, Hyejung;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.1
    • /
    • pp.35-41
    • /
    • 2021
  • [Purpose] This pilot study aimed to develop a regression model to estimate the excess post-exercise oxygen consumption (EPOC) of Korean adults using various easy-to-measure dependent variables. [Methods] The EPOC and dependent variables for its estimation (e.g., sex, age, height, weight, body mass index, fat-free mass [FFM], fat mass, % body fat, and heart rate_sum [HR_sum]) were measured in 75 healthy adults (31 males, 44 females). Statistical analysis was performed to develop an EPOC estimation regression model using the stepwise regression method. [Results] We confirmed that FFM and HR_sum were important variables in the EPOC regression models of various exercise types. The explanatory power and standard errors of estimates (SEE) for EPOC of each exercise type were as follows: the continuous exercise (CEx) regression model was 86.3% (R2) and 85.9% (adjusted R2), and the mean SEE was 11.73 kcal, interval exercise (IEx) regression model was 83.1% (R2) and 82.6% (adjusted R2), while the mean SEE was 13.68 kcal, and the accumulation of short-duration exercise (AEx) regression models was 91.3% (R2) and 91.0% (adjusted R2), while the mean SEE was 27.71 kcal. There was no significant difference between the measured EPOC using a metabolic gas analyzer and the predicted EPOC for each exercise type. [Conclusion] This pilot study developed a regression model to estimate EPOC in healthy Korean adults. The regression model was as follows: CEx = -37.128 + 1.003 × (FFM) + 0.016 × (HR_sum), IEx = -49.265 + 1.442 × (FFM) + 0.013 × (HR_sum), and AEx = -100.942 + 2.209 × (FFM) + 0.020 × (HR_sum).

Fabrication and Evaluation of a Total Organic Carbon Analyzer Using Photocatalysis

  • Do Yeon Lee;Jeong Hee Shin;Jong-Hoo Paik
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.140-146
    • /
    • 2023
  • Water quality is crucial for human health and the environment. Accurate measurement of the quantity of organic carbon in water is essential for water quality evaluation, identification of water pollution sources, and appropriate implementation of water treatment measures. Total organic carbon (TOC) analysis is an important tool for this purpose. Although other methods, such as chemical oxygen demand (COD) and biochemical oxygen demand (BOD) are also used to measure organic carbon in water, they have limitations that make TOC analysis a more favorable option in certain situations. For example, COD requires the use of toxic chemicals, and BOD is time-consuming and can produce inconsistent and unreliable results. In contrast, TOC analysis is rapid and reliable, providing accurate measurements of organic carbon content in water. However, common methods for TOC analysis can be complex and energy-intensive because of the use of high-temperature heaters for liquid-to-gas phase transitions and the use of acid, which present safety risks. This study focuses on a TOC analysis method using TiO2 photocatalysis, which has several advantages over conventional TOC analysis methods, including its low cost and easy maintenance. For TiO2, rutile and anatase powders are mixed with an inorganic binder and spray-coated onto a glass fiber substrate. The TiO2 powder and inorganic binder solutions are adjusted to optimize the photocatalytic reaction performance. The TiO2 photocatalysis method is a simple and low-power approach to TOC analysis, making it a promising alternative to commonly used TOC analysis methods. This study aims to contribute to the development of more efficient and cost-effective approaches for water quality analysis and management by exploring the effectiveness and reliability of the developed equipment.

Analysis of the eddy covariance method data by gas analyzer types (가스분석기 측정 형태별 에디공분산 자료 분석)

  • Lee, Jung Hoon;Kim, Ki Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.201-201
    • /
    • 2020
  • 수문 순환 및 물 수지에 관한 연구는 강수량, 지표유출량, 지하수, 토양수분 및 증발산량에 대한 정량화가 이루어질 때 실제적으로 규명될 수 있다. 그러나, 수문 순환 및 물수지 평가에 중요한 부분을 차지하는 증발산량의 경우 관측값보다 단순한 가정이나 경험식에 의한 추정값을 사용하고 있어 그 자료의 신뢰성에 대해서도 꾸준히 문제가 제기되어 왔다. 따라서, 수문 순환 및 물수지의 정량적인 분석을 위해서는 수문 순환 과정에서 상당부분을 차지하는 증발산량의 측정(실측)이 필요한 실정이다. 본 연구는 환경부의 기초수문자료 구축사업의 일환으로 수행되고 있으며, 에디공분산 기술을 사용하여 증발산량을 직접 관측하고 있다. 에디공분산 방법으로 증발산량을 측정하기 위해서 필요한 장비 중 수증기 농도를 측정하는 장비(개회로 기체분석기, 폐회로 기체분석기<수증기 농도를 측정하는 부분의 개폐여부에 따른 장비 구분>)에 대해 비교 측정을 수행하였으며, 관측 지점은 인위적인 관개가 이루어지고 있는 논경지(청미천 관측소)에서 수행하였다. 측정 자료에 대한 검토는 측정 장비에 따른 자료의 특성을 비교하기 위해 약 13,000개(9개월, 30분 간격) 자료를 활용하여 분석을 수행하였다. 그 결과 두 측정장비 모두 농도 변화에 따른 경향성은 유사하게 나타났으나, 측정 자료의 취득률에서는 차이(약 20%)를 보이는데, 이는 개회로 측정 장비의 경우 강우 및 안개 등의 기상상황에 따라 영향을 받기 때문으로 판단된다. 에디공분산 방법을 이용한 증발산량은 여러 기상자료를 이용하여 보정을 수행하기 때문에 측정 장비의 취득률로 인한 증발산량 산정에는 문제가 되지 않을 것으로 판단된다. 단 높은 관측률 및 측정 자료를 위해서는 폐회로 측정 장비를 이용하는 것이 유리할 것으로 판단된다.

  • PDF

Effect of physicochemical properties and feed mix ratios on the carbothermic reductions of iron ore with coke

  • S.R.R. Munusamy;S. Manogaran;F. Abdullah;N.A.M. Ya'akob;K. Narayanan
    • Advances in materials Research
    • /
    • v.13 no.3
    • /
    • pp.161-171
    • /
    • 2024
  • This study aimed to investigate the effect of physicochemical properties and mix ratios of iron ore (oxide feed): coke (reductant) on the carbothermic reductions of iron ore. Coke size was fixed at ≤63 ㎛ while iron ore size varied between 150-63 ㎛ and ≤63 ㎛ respectively. Mix ratios were changed from 100:0 (reference) to 80:20 and 60:40 while the temperature, heating rate and soaking duration in muffle furnace were fixed at 1100 ℃, 10 ℃/min and 1 hour. Particle size analyzer, XRF, CHNS and XRD analyses were used for determination of raw feed characteristics. The occurrence of phase transformations from various forms of iron oxides to iron during the carbothermal reductions were identified through XRD profiles and supported with weight loss (%). XRF analysis proved that iron ore is of high grade with 93.4% of Fe2O3 content. Other oxides present in minor amounts are 2% Al2O3 and 1.8% SiO2 with negligible amounts of other compounds such as MnO, K2O and CuO. Composite pellet with finer size iron particles (≤63 ㎛) and higher carbon content of 60:40 exhibited 45.13% weight lost compared to 32.30% and 3.88% respectively for 80:20 and 100:0 ratios. It is evident that reduction reactions can only occur with the presence of coke, the carbon supply. The small weight loss of 3.88% at 100:0 ratio occurs due to the removal of moisture and volatiles and oxidations of iron ore. Higher carbon supply at 60:40 leads into better heat and mass transfer and diffusivity during carbothermic reductions. Overall, finer particle size and higher carbon supply improves reactivity and gas-solid interactions resulting in increased reductions and phase transformations.