• Title/Summary/Keyword: Gas accident analysis

Search Result 308, Processing Time 0.02 seconds

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

A Study on the Characteristic Analysis of Blue OLED for the Luminous Traffic Safety Mark (발광형 교통안전표지용 청색 OLED의 특성분석에 관한 연구)

  • Kang, Myung-Goo;Kim, Jung-Yeoun;Oh, Hwan-Sool
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2007
  • Luminous traffic safety mark is restricted to use only the place that has a thick fog, many night traffic accidents, limited field of view due to structure of road. Recently, LEDs are used for luminous traffic safety mark, but we propose an organic LED for a novel luminous traffic safety mark in the near future. The device structure was $ITO/2-TNATA(500{\AA})/{\alpha}-NPD(200{\AA})/DPVBi(300{\AA})/BCP(10{\AA})/Alq_3(200{\AA})/LiF(10{\AA})/Al:Li(1000{\AA})$. The characteristics of the device are most efficient on occasion of using $N_2$ gas plasma treatment. Current density is $240.71mA/cm^2$ luminance $10,550cd/m^2$, and current efficiency 3.53cd/A at an applied voltage of 10V. The maximum EL wavelength of the fabricated blue organic light-emitting device is 456nm. CIE color coordinates are x=0.1449 and y=0.1633, which is similar to NTSC deep-blue color with CIE color coordinates of x=0.14 and y=0.08.

  • PDF

A Study on the Change of Traffic Accidents Around the Pedestrian Priority Zone (보행자 우선도로 개선 사업으로 인한 교통사고 변화에 대한 연구)

  • JANG, Jae-Min;LEE, Young-Ihn;KIM, Sukhee;CHOI, Hoi-Kyun
    • Journal of Korean Society of Transportation
    • /
    • v.36 no.2
    • /
    • pp.112-128
    • /
    • 2018
  • We are implementing pedestrian priority zone policy to certain districts to reduce greenhouse gas and to develop eco-friendly city which has more focus on pedestrians' walking environment. This policy has contributed to citizens' satisfaction level with improved public transportation service as well as more spacious streets for walk. Despite highly positive influence of pedestrian priority zone policy to the walking environment, we need to anticipate the impact of this to traffic environment as it may have bad effect to the overall traffic flow around the zone where the policy is implemented. This research has analyzed the change of characteristics of traffic accidents around the eco-traffic area of Hang-Gung dong, Suwon city, to understand impact of the pedestrian priority zone policy to the traffic surroundings, with pre-post analysis methodology. As a result, number of accidents related to pedestrians showed decrease as pedestrian priority zone is designed operated with focus to pedestrians. But accidents related illegal U-turn and violation of the traffic signal showed (significant) increase as there was a restriction of turns and decrease of overall traffic speed. To prevent the accidents above, we need to notice drivers to pay special attention before the pedestrian priority zone event, and information from this research should be given to the drivers through safety signs and mobile application at the place near to the event.

The Design and Implementation of a Real-Time FMD Cattle Burial Sites Monitoring System Based-on Wireless Environmental Sensors (u-EMS : 센서네트워크 기반의 가축매몰지 악취환경정보 실시간 모니터링 시스템 설계 및 구현)

  • Moon, Seung-Jin;Kim, Hong-Gyu;Park, Kyu-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1708-1721
    • /
    • 2011
  • Recent outbreak of cattle diseases such as foot-and-mouth disease(FMD) requires constant monitoring of burial sites of mass cull of cattles. However, current monitoring system takes environmental samples from burial sites with period of between one and two weeks, which makes it impossible for non-stop management of hazardous bio-waste. Therefore, in this study, we suggest an improved real-time environmental monitoring system for such bio-hazardous sites based on wireless sensor networks, which makes constant surveillance of the FMD burial sites possible. The system consists mainly several wireless environmental monitoring sensors(i.e dust, Co2, VOC, NH3, H2S, temperature, humidity) nodes and GPS location tracking nodes. Through analysis of the relayed of the environmental monitoring data via gateway, the system makes it possible for constant monitoring and quick response for emergency situation of the burial sites. In order to test the effectiveness of the system, we have installed a set of sensor to gas outlets of the burial sites, then collected and analyzed measured bio-sensing data. We have conducted simulated emergency test runs and was able to detect and monitor the foul smell constantly. With our study, we confirm that the preventive measures and quick response of bio environmental accident are possible with the help of a real-time environmental monitoring system.

Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor (연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석)

  • Choi, Jungwoon;Lee, Sunil;Park, Ki-Jung;Seo, KyoungWoo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • The domestic unique research reactor, HANARO (Hi-flux Advanced Neutron Application ReactOr), has been constructed with the open-pool, the core is submerged in, for the multi-purpose neutron application. The reactor has a primary cooling system to remove the fission heat from the core and its connected fluidic systems. Since the works are required at the reactor pool top as a characteristic of the research reactor, the radiation shall be minimized with the operation of the hot water layer system to avoid unnecessary radiation exposure on the workers during work at the pool top. Moreover, the pool water management system is connected to the reactor pool to maintain the pool temperature below $50^{\circ}C$ to minimize the uprising radioactive gas or impurity from the colder pool bottom. For the efficient flow rate of the PWMS, the thermal capacity of heat exchanger is selected with 260 kW in the normal operation condition. In this paper, the modeling is formulated to figure out whether or not each pool temperature maintains below the temperature limit and the calculation results show that the designed PWMS heat exchanger has enough capacity with the design margin regardless of the reactor operation mode.

Development of Questionnaire Measuring Quality of Life in Pneumoconioses (진폐증 환자의 삶의 질 설문지 개발)

  • Baak, Young-Mann;Ahn, Byoung-Yong;Mun, Je-Hyeok;Jeong, Jin-Sook;Kim, Ji-Hong;Kim, Kyoung-Ah;Lim, Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.1
    • /
    • pp.54-66
    • /
    • 2000
  • Background: Pneumoconiosis, like other chronic respiratory diseases, is essentially incurable and, for many, progressive. While improved survival time is an important aim of treatment, there is growing recognition that for some people, improving the quality of life is more important than extending the length of life. Currently the measurement of the quality of life is used to assess the efficacy of therapeutic agents. Methods: Sixty-three pnemoconiotics who were admitted to St. Mary's Hospital between April and August 1999 were interviewed using COOP charts, Chronic Respiratory Questionnaire(CRQ) and Pneumoconiotic Respiratory Questionnaire(PRQ), a newly developed questionnaire concerning clinical and socioeconomic features of pneumoconiotics. Also, ILO classification of the chest film, pulmonary function test, and arterial blood gas analysis of the patients were evaluated. The scores between Industrial Accident Compensation Insurance(IACI) covered and uncovered patients and between clinically stable and unstable patients were compared. Results: Domains of CRQ and PRQ showed a high internal consistency reliability($\alpha$=0.86-0.89, 0.77-0.81) except the dyspnea domain($\alpha$=0.63) of CRQ. The scores on the CRQ and PRQ showed statistically significant correlations with the results of COOP charts, pulmonary function test and arterial blood gas analysis. The dyspnea domain and social activity domain of the PRQ showed significant difference between IACI covered and uncovered patients and between clinically stable and unstable patients. Conclusion : Korean translation of the Chronic Respiratory Questionnaire and the newly developed Pneumoconiotic Respiratory Questionnaire are reliable and valid methods and are likely to be useful in measuring the quality of life in patients with the chronic respiratory disease including pneumoconiosis.

  • PDF

An educational needs analysis of precautions against of safety accidents for school foodservice employees in the Jeonbuk area using Borich priority formula and the Locus for Focus Model (Borich 요구도와 The Locus for Focus Model을 이용한 전북지역 학교급식 조리종사자의 안전사고 예방관리를 위한 교육요구도 우선순위 분석)

  • Hyang Jin Lee ;Sun A Choi ;Jeong Ok Rho
    • Journal of Nutrition and Health
    • /
    • v.56 no.5
    • /
    • pp.554-572
    • /
    • 2023
  • Purpose: The purpose of the study was to analyze the priorities for educational content regarding precautions to be taken to prevent safety accidents for employees in school foodservice using the Borich priority formula and the Locus for Focus model. Methods: A survey was conducted in February 2019 on 194 employees in elementary school and 122 employees in middle- and high school foodservice in the Jeonbuk area. Demographic characteristics, status of safety accidents, safety education, and their importance and performance levels were assessed using a self-administered questionnaire. The priorities for the educational content on precautions to prevent safety accidents were based on a 3-step analysis method, including the paired sample t-test, Borich priority formula, and the Locus for Focus Model. Results: The average perceived importance of the precautions to be taken against safety accidents of employees in elementary-, middle-, and high schools was higher compared to the average performance of the employees (p < 0.001). The top priority for elementary school employees was caution against falls during the cleaning of the gas hood and the trench in the kitchen. In addition, 'awareness of chemical signs' was added as one of the top priorities of middle- and high school employees. The second highest priority items were 'do stretching', 'safely adjusting workbench height', 'keeping the right attitude', 'using assistive devices when moving heavy things', and 'checking the material safety data sheet', which were the same for all elementary, middle- and high school employees. Conclusion: Thus, to improve the educational preparedness of employees in the area of safety precautions, eight safety/accident prevention items should be included in the safety education program.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF