• Title/Summary/Keyword: Gas Valves

Search Result 181, Processing Time 0.024 seconds

A Study on the Improvement of Preventive Measures for Improving the Safety of Chemical Reactor (화학반응기의 안전성 향상을 위한 예방조치 개선에 관한 연구)

  • Byun, Yoon Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.32-38
    • /
    • 2020
  • Based on the cases of fire and explosion accident in the chemical reactor, thr problems of preventive measures installed in the chemical reactor were analyzed. The chemical reactors produce a variety of chemicals and install rupture disk to relieve the pressure that rises sharply in the event of a runaway reaction. In order to maintain the function of the rupture disk, the emissions was allowed to be discharged into the atmosphere, resulting in fire and explosion accidents. As a way to improve this, safety instrumented system based on the safety integrity level(SIL3) was applied as a preventive measures for chemical reactor. Two emergency shur-off valves are installed in series on pipe dropping raw materials for chemical reactor so that the supply of raw materials can be cut off even if only one of the two emergency shut-off valves is operated during the runaway reaction. The automatic on/off valve is installed in parallel in the supply pipe of the reaction inhibitor so that the reaction inhibitor can be injected even if only one valve is opened at the time of the runaway reaction.

The Effects of an Abnormal Adjusting Intake and Exhaust Valves on the Combustion Characteristics of SI Engine (흡.배기 밸브의 밀착이상이 엔진연소특성에 미치는 영향)

  • Park Kyoung-Suk;Son Sung-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.123-129
    • /
    • 2005
  • The unbalance of the power output, noise, and vibration is happened by the disproportionate pressure variation in the cylinder. For this reason, decrease of the pressure in the cylinder and increase of the residual gas effect on the engine performance. If the abnormal combustion is continued, the crack would be occurred in the engine block. And it could be broken down. For the normal combustion of the SI engine, it is important to supply the balanced mixture by each operating condition. In this study, it was tested the combustion characteristics in the cylinder according to the abnormal adjusting of intake & exhaust valve. This test is willing to set a basic data's analysis fur developing an automotive diagnosis system by analyzing the pressure in the cylinder, the output signal of MAP sensor, the exhaust gas, etc.

Dynamic Analysis on the Tail Gate System for Vehicle with the Energy Regenerative Brake of Hydraulic Driven Systems (유압 구동계 에너지 재생 브레이크를 적용한 자동차 테일게이트 개폐장치에 대한 동특성 해석)

  • Choi, Soon-Woo;Huh, Jun-Young
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.2
    • /
    • pp.19-26
    • /
    • 2010
  • The typical trunk lid system for vehicle is composed of a hinge having 4-bar link and gas lifter. Here, the energy regenerative brake of hydraulic driven systems is applied to the tail gate system for vehicle and removed the gas lifter. The new tail gate system is composed of a hydraulic pump by electric motor, a hydraulic motor, four check valves, an accumulator, a relief valve and a directional control valve. The dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, are investigated in both brake action and acceleration action. The capacity selection method of accumulator by mathematical model is based upon trial and error approach and computer simulation by AMEsim software is carried out.

  • PDF

THE CHARACTERISTIC OF A TWO STAGE AMMONIA RECIPROCATING COMPRESSOR (왕복동 압축기의 성능에 대하여)

  • CHO Kweoun Ock;OH Hoo Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.10 no.1
    • /
    • pp.65-69
    • /
    • 1977
  • The characteristics of two stage compressor which is constituted of two separated reciprocating compressors was tested measuring the volumetric efficiency of each compressor at suction of both bighandlowpressdresideusillgorificetypeflolrmeters. The volumetric efficiency of low pressure side compressor was lower than that of the high side when they were operating under the same compression ratio. And it tended to reduce obviously by lowering evaporating temperature resulting in a markable reduction of refrigerating capacity at the same time. It is assumed that the falling of volumetric efficiency at low side compressor was directed by the decrease in evaporating temperature which derives the falls of gas pressure at suction, increase in compression ratio, and gas flow resistance at suction and discharge valves.

  • PDF

The effects of gas flow in intake and exhaust system on volumetric efficiency (흡배기계의 가스유동이 체적효율에 미치는 영향)

  • 조진호;김병수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.57-65
    • /
    • 1988
  • The study of unsteady gas exchange processes in the intake and exhaust systems of four-cylinder, four-stroke cycle internal combustion engine is described in this paper. The calculation model for the intake and exhaust systems is established and solved by the characteristic method for the equations defining these systems. A constant pressure theory is used for modeling branches of intake and exhaust manifolds. The relationship between the volumetric efficiency and the intake, exhaust pressure variation is clarified by simulation of these systems. It is found that the volumetric efficiency mainly depends on the intake pressure during the short period before the intake valves is closed, that the volumetric efficiency is influenced a little by intake chamber volume in the intake and exhaust system.

  • PDF

Dynamics modeling of a GHP in cooling mode for development of control algorithm (제어 알고리즘 개발을 위한 GHP 냉방모드 동특성 모델링)

  • Shin Younggy;Kim Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.243-249
    • /
    • 2005
  • The present study has been conducted to simulate dynamics of a gas engine-driven heat pump(GHP) for design of control algorithm. The dynamic modeling of a GHP was based on conservation laws of mass and energy. For automatic control of refrigerant pressures, actuators such as engine speed, outdoor fan, coolant three-way valves and liquid injection valve were PI or P controlled. The simulation results showed physical behavior that is realistic enough to apply for control algorithm design.

A New Approach to the High Efficiency of Hydraulic Excavator (유압식 굴삭기의 고효율 화에 관한 새로운 접근)

  • Lee, Y.B.
    • Journal of Drive and Control
    • /
    • v.11 no.4
    • /
    • pp.39-45
    • /
    • 2014
  • With recent oil price increases, the fuel efficiency of hydraulic excavators has become a serious issue. Researchers have considered weight lightening by high pressurization in order to improve the efficiency of the excavator and pump controlled actuation (PCA) and to reduce pressure loss of hybrid and valves using mechanical inertia. However, high pressurization is not very effective because the excavator operates at a low speed; a hybrid is inefficient because little accumulated inertial energy is accumulated; and PCA is ineffective because control precision and responsibility are low. In this study, a method to minimize air and gas in hydraulic oil has been presented as a simple and new way to increase hydraulic efficiency.

A Simulation for Indentifying Influence of The VVT Effect on The SI Engine Performance Using WAVE (WAVE 를 이용한 VVT 효과가 SI 엔진성능에 미치는 영향에 관한 시뮬레이션)

  • Lim, Ock-Taeck;Kim, Dae-Ho;Dutta, Diganta;Tsogtjargal, G.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3032-3037
    • /
    • 2008
  • Variable Valve Timing (VVT) system can be used to improve fuel economy, performance and emissions. This study is identified the effect of VVT in terms of wide open throttle torque, Residual gas fraction, volume efficiency. Engine cycle simulations are performed on 2.0L DOHC in-line 4-cylinder SI engine by using WAVE of Ricardo. Results of the simulations had good agreement with WOT torque experimental data, and helped to predict the tendency of performance as the valve timings change. WOT torque was higher when intake valves were closed early for low rpm and late for high rpm.

  • PDF

A Study on Standards for Pressure Relief Valve Vent Pipes from LPG Storage Tanks (LPG용 압력방출밸브 방출관 설치기준 개선방안)

  • Lee, Jin-Han;Eom, Suk-Hwa;Kim, Lae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.59-64
    • /
    • 2012
  • The dispersion of gas discharged from the vent pipes of pressure relief valves attached LPG (Liquefied Petroleum Gas) storage tank was studied. In general, vent pipes should be positioned so that they discharge vertically upwards in a safe place, and installed so that, in the event of ignition of discharged gas, flame impingement on any vessel, equipment or piping is avoided[1][2]. In Korea, on the other hand, there are various type of the end of vent pipes because there is no rule for discharge directions from the vent pipes. In this paper, we took 4 types of vent directions from the pipes in to account, such as vertically upward, vertically downward, vertically 4-way and horizontally 2-way direction. A software package, FLACS, was adopted to simulate gas dispersion from the vent pipes. We found that vertically downward, vertically 4-way and horizontally 2-way discharge from vent pipes were undesirable to avoid ignition on near ground. Therefore, it was obvious that vertically upward opening of a vent pipe is the best option to discharge in a safe place.

Thermodynamic Analysis on Hybrid Molten Carbonate Fuel Cell - Turbo Expander System for Natural Gas Pressure Regulation (용융탄산염연료전지와 터보팽창기를 이용한 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.28-34
    • /
    • 2014
  • In the natural gas pressure regulation station, high pressure natural gas is decompressing using pressure regulation valves. Waste pressure occurred in the pressure regulation process can be recovered through adopting turbo expanders. However, in the waste pressure recovery process, Joule Thompson effect causes below $0^{\circ}C$ and this low temperature freezes outside land of pipeline or generates methane hydrate in the pipeline which can block the pipeline. Therefore, turbo expander systems are accompanying with a boiler for preheating natural gas. Molten carbonate fuel cell (MCFC), one of the high temperature fuel cell, can use natural gas as a direct fuel and is also exhausting low emission gas and generating electricity. In this paper, a thermodynamic analysis on the hybrid MCFC-turbo expander system is conducted. The fuel cell system is analyzed for the base load of the hybrid system.