• Title/Summary/Keyword: Gas Transport

Search Result 861, Processing Time 0.035 seconds

Porometric Study on the Gas Diffusion Layer in PEMFCs Using Method of Standard Porosimetry (MSP 기법을 적용한 고분자 전해질 연료전지 가스확산층의 포로시메트리 연구)

  • Lee, Yongtaek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.64-69
    • /
    • 2013
  • The structure of pore network of gas diffusion layers (GDLs) in PEMFCs plays a critical role in determining the transport phenomena of reaction gas as well as generated water. In addition, the interactive characteristics between water and surface of pore are no less important than the structural characteristics of pore network. In this study, porometric investigation is conducted for two kinds of GDL using method of standard porosimetry which enable to distinguish hydrophobic pores from hydrophilic pores of GDLs. The porosity of TGPH-120 decreases by 6% by adding 30 wt.% of PTFE, but the porosity of hydrophilic pores decreases by 12%. The relation of $p_c-S_{nw}$ varies with the addition of PTFE, especially at low $p_c$.

Gas Phase Analysis of the Diamond CVD Reaction by Hot Filament Method (열필라멘트법에 의한 다이아몬드 CVD반응의 기상 조성 분석)

  • 서문규
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.11
    • /
    • pp.1233-1239
    • /
    • 1998
  • Gas phase compositions of the hot filament-assisted diamond CVD reaction were analyzed by on-line quadrupole mass analysis(QMA) technique. D2 isotope experiments showed that methance molecules were decomposed into atomic state and then recombined in to acetylene during transport the probe line. Although acetylene or ethylene was supplied instead of methane similar gas compositions were obtained when filament temperature was above 1500$^{\circ}C$ Therefore this system could be assumed near thermal equilibrium state. Filament temperature and reaction pressure variation experiments exhibited the same tendency between acetylene concentration and diamond growth rate and these results implied that acetylene molecule played the role of the reactive species in the diamond CVD reaction.

  • PDF

A finite Element Analysis on the discharge characteristics of $SF_6$ gas ($SF_6$ 가스 방전 특성의 유한요소해석)

  • 최승길;심재학;강형부
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.265-272
    • /
    • 2000
  • In this paper the corona discharge in SF$_{6}$ gas used as insulating material in lots o high voltage equipment, is simulated by finite element method with Flux-Corrected Transport(FCT) method. By application of proposed method the negative corona discharge characteristics in needle to plane electrode is analyzed with time step. For the accuracy of analysis the secondary electron emission by photon and ion are also considered as well as the accuracy of analysis the secondary electron emission by photon and ion are also considered as well as townsend first ionization and electron attachment. The calculated results show that the electric field intensity between anode and ion group is decreased as times go-by according to field distortion by those space charge. Accordingly the electron density is decreased strongly by the attatchment effect of SF6 gas so that the corona discharge becomes extinguished abruptly.y.

  • PDF

Numerical Study on Flow and Heat Transfer in a CVD Reactor with Multiple Wafers

  • Jang, Yeon-Ho;Ko, Dong Kuk;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.91-96
    • /
    • 2018
  • In this study temperature distribution and gas flow inside a planetary type reactor in which a number of satellites on a spinning susceptor were rotating were analyzed using numerical simulation. Effects of flow rates on gas flow and temperature distribution were investigated in order to obtain design parameters. The commercial computational fluid dynamics software CFD-ACE+ was used in this study. The multiple-frame-of-reference was used to solve continuity, momentum and energy conservation equations which governed the transport phenomena inside the reactor. Kinetic theory was used to describe the physical properties of gas mixture. Effects of the rotation speed of the satellites was clearly seen when the inlet flow rate was small. Thickness of the boundary layer affected by the satellites rotation became very thin as the flow rate increased. The temperature field was little affected by the incoming flow rate of precursors.

First-Principles Study on Thermodynamic Stability of UO2 with He Gas Incorporation via Alpha-Decay

  • Kwon, Choa;Lee, Kwanpyung;Han, Byungchan
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.368-371
    • /
    • 2019
  • Using first principles calculations we investigated the thermomechanical stability of spent nuclear fuels (SNF), especially how mechanical properties of $UO_2$, such as, bulk, shear and Young's moduli and Poisson's ratio vary through alpha-decay of U into Th with generation of He gas. Our results indicate that substitution of U by Th through alpha decay ($U_{1-x}Th_xO_2$) does not significantly affect the stability of the grain in a fuel matrix. In addition, we studied the transport properties of He in and boundaries of the $U_{1-x}Th_xO_2$ grain. Helium preferentially resides at the grain boundaries through diffusion. Our study can contribute to substantial reduction of environmentally risk and enhancement of our sustainability by safe control of radioactive materials.

Molecular Dynamics (MD) Study of Polymeric Membranes for Gas Separation (기체 분리용 고분자 분리막의 분자동력학 연구)

  • Park, Chi Hoon;Kim, Deuk Ju;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.341-349
    • /
    • 2014
  • Molecular dynamics (MD) computer simulation is a very useful tool to calculate the trajectory and velocity of particles (generally, atoms), and thus to analyze the various structures and kinetic properties of atoms and molecules. For gas separation membranes, MD has been widely used for structure analysis of polymers such as free volume analysis and conformation search, and for the study of gas transport behavior such as permeability and diffusivity. In this paper, general methodology how to apply MD on gas separation membranes will be described and various related researches will be introduced.

Color Gradients of Isolated Late-type Galaxies

  • Kim, Ji-Hun;Im, Myeong-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.32.1-32.1
    • /
    • 2012
  • Radial color gradient of disk galaxies has been a key tool for diagnosing the ages and metallicities of the stars and gas of these galaxies, and thus, the formation process of these disks. In many cases, observational data support the 'inside-out' picture of disk galaxy formation proposed by Larson (1976). In this scenario, gas within dark matter halos cools and accretes on to the outer disk while enhancing star formation in the disk. Recent discoveries of "extended ultra-viloet" (XUV) disks also show that majority of disk galaxy experience active star formation within out disks where gas surface density is quite low (Thilker et al. 2007; Gil de Paz et al. 2007). However, neither gas, nor stars stay put within galaxies. They rather migrate into bulges, disperse throughout galaxies, or flow into and out of galaxies via various mechanisms. There have been a few notable studies to investigate how radial star formation and metal abundance gradients vary across populations of disk galaxies systematically. However, the mechanisms driving gas transport are still poorly understood. Cross-matching various galaxy catalogs including KVAGC and UKIDSS, we are investigating if color gradients of late-type galaxies depend on their physical properties, especially on environmental properties. We will present the result from the pilot study on Karachentsev isolated galaxy catalog.

  • PDF

CAE Analysis of $SF_6$ Arc Plasma for a Gas Circuit Breaker Design (가스차단기 최적설계를 위한 $SF_6$ 아크 플라즈마 CAE 해석)

  • Lee Jong C.;Ahn Heui-Sub;Kim Youn J.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.365-368
    • /
    • 2002
  • The design of industrial arc plasma systems is still largely based on trial and error although the situation is rapidly improving because of the available computational power at a cost which is still fast coming down. The desire to predict the behavior of arc plasma system, thus reducing the development cost, has been the motivation of arc research. To interrupt fault current, the most enormous duty of a circuit breaker, is achieved by separating two contacts in a interruption medium, $SF_{6}$ gas or air etc., and arc plasma is inevitably established between the contacts. The arc must be controlled and interrupted at an appropriate current zero. In order to analyze arc behavior in $SF_{6}$ gas circuit breakers, a numerical calculation method combined with flow field and electromagnetic field has been developed. The method has been applied to model arc generated in the Aachen nozzle and compared the results with the experimental results. Next, we have simulated the unsteady flow characteristics to be induced by arcing of AC cycle, and conformed that the method can predict arc behavior in account of thermal transport to $SF_{6}$ gas around the arc, such as increase of arc voltage near current zero and dependency of arc radius on arc current to maintain constant arc current density.

  • PDF

The Analysis of Energy Consumption Characteristics of the Apartment (공동주택 에너지 소비 경향 분석에 관한 연구)

  • Lee, Hyun-Jung;Park, Sun-Hyo;Bae, Sang-Hwan;Lee, Byung-Seok;Kim, Yang-Sub
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.305-310
    • /
    • 2012
  • In 2009, The Ministry of Land, Transport and Maritime Affairs, Korea opens apartment maintenance fee to public in "Apartment Management Info System". The high energy consumption component of apartment, which is hot water, water, electricity and heating, is released to public on this system. Through this system, apartment energy consumption and greenhouse gas emissions data can be compiled and expected to be accurately analyzed. Energy consumption and greenhouse gas emissions statistics of the apartment are collected being made to reduce energy and gas emissions. However, The accurate survey of energy consumption trends have not been accomplished. The energy consumption and greenhouse gas emissions survey in Apartment should be made first in order to reduce energy consumption. and then the correlation factors analysis which is affecting energy consumption is required. The purpose of this study is to analyze energy consumption characteristics of apartment in Bundann-gu, Seongnam, Korea in monthly, unit area and building built year basis. And then the research can be used as the basis of policy to Reduce energy consumption and greenhouse gas emissions.

  • PDF

세라믹 가스센서를 이용한 토양증기추출공정의 배출가스 모니터링 기법 연구

  • 양지원;조현정;이재영;곽무영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.250-252
    • /
    • 2002
  • The goals of environmental monitoring are to locate and quantify the significant contamination, estimate the fate and transport, estimate the potential exposure and risks to humans and the environment, and track the performance of various remedial technologies. In this study, ceramic gas sensor system is proposed to enhance the effectiveness of soil vapor extraction (SVE) process by monitoring the effluent gas. SVE is a technique that is widely used to remediate unsaturated soils contaminated with volatile organic contaminants. The sensor response for benzene, toluene, and xylene, the representative effluent gas compositions of SVE process, was evaluated using the proposed sensor system. As a result, it was verified that the response of sensor was increased or decreased very sensitively according to the change of the effluent gas concentration. Besides, the sensor could detect the difference over a wide range of concentration and it was more sensitive in order of xylene, toluene, and benzene. It is expected that this VOC analysis method results in field monitoring costs saying and appropriate immediate action for process control. More detailed experiments are being conducted in our research group.