• Title/Summary/Keyword: Gas Toxicity

Search Result 196, Processing Time 0.027 seconds

The Experimental Study for the Smoke Optical Density and Toxic Gases of Sandwich Panel Insulations(Single Chamber Method) (샌드위치패널 단열재의 연기농도 및 연소독성가스에 대한 실험적 연구(연소챔버법))

  • Park, Soo-Young;Lee, Woo-Seok;Yeo, Han-Seung;Im, Hong-Soon
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.26-32
    • /
    • 2006
  • Nowadays in Korea, KS F 2271 has been using for the test of fire safety performance of sandwich panels. Smoke toxicity test is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice; however this method is not a quantitative way. This test result can be influenced by the health status of mice and test condition. Specific optical density can be quantitatively measured by ISO 5659-2 single chamber method and toxic gases can be quantitatively measured by FTIR analysis. In this study, specific optical density of sandwich panel insulations, which are widely used in Korea, were tested using the ISO 5659-2 single chamber test method and compared with each test. Also, in the second test of three tests for each specimen, FTIR analysis was performed and quantitative test results(HCl, $NO_2$, etc) were compared with each test result.

A Case of Diffuse Alveolar Damage Induced by Cyclophosphamide (Cyclophosphamide에 의해 유발된 미만성 폐포 손상 1예)

  • Bae, Sang-Su;Bae, Mun-Hee;Park, Hyung-Suk;Park, Jeong-Woong;Suh, Gee-Young;Chung, Man-Pyo;Han, Joung-Ho;Kwon, O-Jung;Lee, Kyung-Soo;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.429-436
    • /
    • 1998
  • Approximately 100 drugs have been reported to affect the lungs adversely. Among these, pulmonary toxicity caused by antieneoplastic agent. is being recognized more frequently. Cyclophosphamide is an immunosuppressive alkylating agent used for the treatment of a wide variety of malignant and nonmalignant diseases. The incidence of pulmonary toxicity is probably less than 1 percent The first case was reported in 1967. Since then, more than 20 well-documented cases of pulmonary toxicity associated with cyclophosphamide have been reported in the literature. In Korea, three patients were identified with cyclophosphamide-induced lung disease. The typical features of toxicity include dyspnea, fever, cough, new parenchymal infiltrates, gas exchangs abnormalities on pulmonary function tests, and pleural thickening on chest roentgenogram. The best approach to management is early diagnosis, discontinuation of the offending drug and administration of corticosteroid therapy. Recently, we experienced a case of diffuse alveolar damage induced by cyclophosphamide. The patient presented with early-onset pulmonary toxicity and died of repiratory failure despite early use of corticosteroid.

  • PDF

Studies on Phytotoxin in Intensively Cultivated Upland Crops -I. Identification of phytotoxin in soil and effects of phytotoxin application to the toxicity of hot-pepper plant (연작재배지토양(連作栽培地土壤)의 식물독소(植物毒素)에 관(關)한 연구(硏究) -제(第)1보(報) 토양중(土壤中) 식물독소(植物毒素)의 분리정량(分離定量) 및 식물독소(植物毒素) 첨가(添加)가 고추 유식물(幼植物)에 미치는 영향(影響))

  • Lee, Sang Kyu;Suh, Jang Sun;Kim, Young Sig;Park, Jun Kyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.20 no.1
    • /
    • pp.63-67
    • /
    • 1987
  • A laboratory experiment was conducted to find out the concentration of phytotoxin in intensively cultivated hot-pepper, garlic and chinese cabbage, and effects of these phytotoxin to the germination and growth of young hot-pepper plant. Also this experiment presents describes of the bio-assay method and results of phytotoxin application to the toxicity of hot-pepper plant. The results obtained were summarized as follows; 1. A series of non-volatile (aromatic) phenolic compounds such as hydroquinone, benzoic-, p-hydroxybenzoic, and vanillic acid were quantitatively and qualitatively analysed using BSA(N, O-bis(trimethylsilyl)acetamide) by means of gas chromatography method. 2. Phytotoxin as hydroquinone, benzoic-, p-hydroxybenzoic- and vanillic acid were determined in intensively cultivated hot- pepper, garlic and chinese cabbage. Highest concentration of phytotoxin was obtained in hot-pepper cultivated soil. 3. Direct toxic action of the applied phytotoxin to the germination and young hot-pepper plant growth was observed at the levels of 200 ppm. Benzoic acid was obtained the highest toxicity to the young hot-pepper plant growth. 4. Mode of actions of phytotoxins to the young hot-pepper plant growth were observed as stunting of stem elongation, discoloration of leaf and oxygen depletion from consideration as causes of symptom.

  • PDF

A Study on the Hazard Area of Bunkering for Ammonia Fueled Vessel (암모니아 연료추진 선박의 벙커링 누출 영향에 관한 연구)

  • Ilsup Shin;Jeongmin Cheon;Jihyun Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.964-970
    • /
    • 2023
  • As part of the International Maritime Organization ef orts to reduce greenhouse gas emissions, the maritime industry is exploring low-carbon fuels such as liquefied natural gas and methanol, as well as zero-carbon fuels such as hydrogen and ammonia, evaluating them as environmentally friendly alternatives. Particularly, ammonia has substantial operational experience as cargo on transport ships, and ammonia ship engines are expected to be available in the second half of 2024, making it relatively accessible for commercial use. However, overcoming the toxicity challenges associated with using ammonia as a fuel is imperative. Detection is possible at levels as low as 5 ppm through olfactory senses, and exposure to concentrations exceeding 300 ppm for more than 30 min can result in irreparable harm. Using the KORA program provided by the Chemical Safety Agency, an assessment of the potential risks arising from leaks during ammonia bunkering was conducted. A 1-min leak could lead to a 5 ppm impact within a radius of approximately 7.5 km, affecting key areas in Busan, a major city. Furthermore, the potentially lethal concentration of 300 ppm could have severe consequences in densely populated areas and schools near the bunkering site. Therefore, given the absence of regulations related to ammonia bunkering, the potential for widespread toxicity from even minor leaks highlights the requirement for the development of legislation. Establishing an integrated system involving local governments, fire departments, and environmental agencies is crucial for addressing the potential impacts and ensuring the safety of ammonia bunkering operations.

Analysis of Toxic Substance (Indotoxin) by Gas Chromatography (기체 크로마토그래피에 의한 독성 물질(내독소)의 분석)

  • 이봉헌;박흥재
    • Journal of Environmental Science International
    • /
    • v.5 no.5
    • /
    • pp.555-560
    • /
    • 1996
  • The toxic substances (endotoxins) from the bacterial cell walls were extracted by using incubator, centrifuge, UV-Vis spectrophotometer, and their fatty acid compositions were analyzed by Gas Chromatography. The lethal toxicities and pyrogenic activities of toxic substances were tested and the results were compared each other. The results of fatty acid analyses showed that the major fatty acid of the toxic substance was tetradecanoic acid for Vibrio vulnificus, dodecanoic acid for Escherichia coli, and decanoic acid for Salmonella typhimurium. These three fatty acids were the main fatty acids ofr three toxic substances (more, than 70%). The unique points in the fatty acid compositions were that tetradecanoic acid was composed as important one (37.15%) for V. vulnificus and that the amount of hexadecanoic acid was very small (below 2%) for three toxic substances. The lethal toxicity in ICR mice of toxic substance from V. vulnificus (LD50 was 52.5 mg/kg) was similar to that of E. coli (56.5mg/kg), but weaker than that of S. typhimurium (37.5mg/kg). Toxic substance from V. vulnificus was more pyrogenic in rabbit than that from E. coli, but less than that from S. typhimurium.

  • PDF

A Study on the Smoke Hazard Increase of Flame-retardant-treated Interior Decorative Textile -Focused on Viscose Rayon Textile Wallcovering- (난연 처리된 실내장식섬유의 연기 위해성 증가에 관한 연구 -비스코스 레이온 섬유 벽지를 중심으로-)

  • Lee, Joonhan;Kim, Sun Mee
    • Journal of Fashion Business
    • /
    • v.24 no.3
    • /
    • pp.30-39
    • /
    • 2020
  • This study was conducted to identify problems in domestic flame-retardant performance specifications. Currently, the domestic wallcovering anti-inflammatory regulations are not prepared for damage caused by smoke, with the carbonized area as the main function. In particular, given that smoke is the main cause of human casualties and injuries in a fire, it is reasonable that the flame density and toxicity of the wallcovering should also be the main performance indicators. The scope and method of research in this study were as follows. First, a prior study related to fire on various wallcoverings was considered. Second, it raised questions about the effects of smoke in the event of a fire and domestic anti-inflammatory performance tests. Third, textile wallcovering samples were manufactured with viscose rayon for experimental verification of the problems and tested by Korean and EU standards without flame retardant processing to analyze the differences between each regulation. Fourth, the performance of flame retardant wallcovering according to Korean standards was evaluated using smoke density and harmful gas testing methods. The results of each test were as follows. Non-fire retardant wallcovering was rejected by Korea standards. However, B-s1.d0 in Europe. Smoke density testing and harmful gas by domestic combustion processing on the same sample showed that the smoke density increased about 4.3 times more than before, and the harmful gas test showed that the suspension of the post-processing sample slowed earlier than the non-processed sample.

Computational Chemistry Study on Gas Hydrate Formation Using HFC & HCFC Refrigerants (R-134a, R-227ea, R-236fa, R-141b) (수소불화탄소 및 수소염화불화탄소 냉매(R-134a, R-227ea, R-236fa, R-141b)를 이용한 가스 하이드레이트 형성에 관한 계산화학적 해석)

  • Kim, Kyung Min;An, Hye Young;Lim, Jun-Heok;Lee, Jea-Keun;Won, Yong Sun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.704-710
    • /
    • 2017
  • Although the desalination technique using gas hydrate formation is at a development stage compared to the commercially well-established reverse osmosis (RO), it still draws attention because of its simplicity and moderate operational conditions especially when using refrigerants for guest gases. In this study, DFT (density functional theory)-based molecular modeling was employed to explain the energetics of the gas hydrate formation using HFC (hydrofluorocarbon) and HCFC (hydrochlorofluorocarbon) refrigerants. For guest gases, R-134a, R-227ea, R-236fa, and R-141b were selected and three cavity structures ($5^{12}$, $5^{12}6^2$, and $5^{12}6^4$) composed of water molecules were constructed. The geometries of guest gas, cavity, and cavity encapsulating guest gas were optimized by molecular modeling respectively and their located energies were then used for the calculation of binding energy between the guest gas and cavity. Finally, the comparison of binding energies was used to propose which refrigerant is more favorable for the gas hydrate formation energetically. In conclusion, R-236fa was the best choice in terms of thermodynamic spontaneity, less toxicity, and low solubility in water.

A Study on the Efficiency Estimation of Halogen free Fire Resistance Cable (저독성 내화전선 케이블의 성능평가에 관한 연구)

  • 윤헌주;홍진웅;유동일;윤재선;곽동일
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • Efficiency estimation of toxicity free resistance cable experiments were conducts to understand toxicity free fire ersistance polyolefin insulation material and smoke density characteristic and combustion gas corrosion analysis. A main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Similar patterned fire incidents such as, Inchon Live-Hof Pub Restaurant as, Sea-land Children Resort have proven that serious loss of lives were caused by hazardous gas generated fire resistance cable materials. In this paper, Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5$\pm40.04〔w/$\textrm{cm}^2$〕for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. Also, the fire gases was occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC which has high content of carbon in chemical compound.

Prediction of Damages and Evacuation Strategies for Gas Leaks from Chlorine Transport Vehicles (염소 운송차량 가스누출시 피해예측 및 대피방안)

  • Yang, Yong-Ho;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.407-417
    • /
    • 2024
  • The objective of this study is to predict and reduce potential damage caused by chlorine gas leaks, a hazardous material, when vehicles transporting it overturn due to accidents or other incidents. The goal is to forecast the anticipated damages caused by chlorine toxicity levels (ppm) and to design effective response strategies for mitigating them. To predict potential damages, we conducted quantitative assessments using the ALOHA program to calculate the toxic effects (ppm) and damage distances resulting from chlorine leaks, taking into account potential negligence of drivers during transportation. The extent of damage from toxic gas leaks is influenced by various factors, including the amount of the leaked hazardous material and the meteorological conditions at the time of the leak. Therefore, a comprehensive analysis of damage distances was conducted by examining various scenarios that involved variations in the amount of leakage and weather conditions. Under intermediate conditions (leakage quantity: 5 tons, wind speed: 3 m/s, atmospheric stability: D), the estimated distance for exceeding the AEGL-2 level of 2 ppm was calculated to be 9 km. This concentration poses a high risk of respiratory disturbance and potential human casualties, comparable to the toxicity of hydrogen chloride. In particular, leaks in urban areas can lead to significant loss of life. In the event of a leakage incident, we proposed a plan to minimize damage by implementing appropriate response strategies based on the location and amount of the leak when an accident occurs.

A Case of Acute Hydrogen Sulfide Intoxication Caused Rapid Loss of Consciousness (급속한 의식 변화를 초래한 급성 황화수소 중독 1례)

  • Ahn, Jung-Hwan;Jung, Yoon-Seok
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.2 no.2
    • /
    • pp.147-150
    • /
    • 2004
  • Hydrogen sulfide is a colorless, and malodorous 'rotten eggs' gas that results from the decay of organic material. It is a byproduct of industry and agriculture. The mechanism of its toxicity is primarily related to inhibition of oxidative phosphorylation, which causes a decrease in available cellular energy. Because there is no rapid method of detection that is of clinical diagnostic use, management decisions must be made based on history, clinical presentation, and diagnostic tests that imply hydrogen sulfide's presence. Although there is some anecdotal evidence to suggest that the early use of hyperbaric oxygen is beneficial, supportive care remains the mainstay of therapy. We describe an occupational exposure to hydrogen sulfide gas in 51-year-old man. While cleaning the sewage of pigs. he became unconscious. When he arrived in the emergency department, he had irritability and confused mentality. The typical smell of rotten eggs on clothing and exhaled air were enough to be considered to be exposed to hydrogen sulfide. Hyperbaric oxygen therapy was performed. He had a recovery to normal function.

  • PDF