• 제목/요약/키워드: Gas Sterilization

검색결과 69건 처리시간 0.032초

Minilaparotomy 불임술(不妊術)과 복강경불임술(腹腔鏡不妊術)에 관(關)한 비교연구(比較硏究) (A Comparison of Minilaparotomy and Laparoscopic Sterilization)

  • 배병주
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제4권1호
    • /
    • pp.17-25
    • /
    • 1977
  • Anderson(1937), Power and Barnes(1941) reported a study concerning a method of tubal sterilization in association with peritoneoscopy or laparoscopy in which they cauterized the tubes. There appears to have been a hiatus of interest in sterilization (cold or hot) associated with laparoscopy until reintroduction by Palmer(1963), Frangenheim(1964) and Steptoe(1967). On the other hand, for interval female sterilization, however, minilaparotomy is relatively new. By Saunder and Munsick(1972), John Lyle(1974), Frank Stubb(1974), Vitoon(1973) and B.C. Bai(1975), their own technique for interval female sterilization requires 2.0 to 2.5cm, incision at the margin of the mons pubis. In Korea, female sterilization by means of minilaparotomy firstly reported by B.C. Bai using Bai's uterine elevator, of his own device, early in 1975. Recently inteval female sterilization by laparoscopy and minilaparotomy are widely accepted throughout the world especially in Asian countries. Minilaparotomy is carried out from 1974, laparoscopic sterilization from 1976, and in this study each of 250 cases of those were analysed and discussed for the comparison at Seoul Red Cross Hospital. (1) In the age distribution, numerous clients were in their age of $31{\sim}35$ in laparoscopy as well as minilaparotomy. Average 33.7 years in L and 33.2 years in M. (M=minilaparotomy, L=laparoscopic sterilization) (2) As regarding living children, women having 3 children represented the greatest number, 113 cases out of 250 in M group and 102 cases out of 250 in L group. Average No. of child are 2.9 in Land 3.1 in M. (3) Concidering the operation day in the menstrml cycle, the greatest number of cases, those who underwent tubal sterilization during the days of $26{\sim}$, next during the $6{\sim}10$ days of the cycle in both group. (4) Concidering the operation time, 188 cases by laparoscopy were performed in $6{\sim}10$ minutes, 33 cases within 5 minutes and 24 cases in $11{\sim}15$ minutes. Maximum 50 minutes, minimum 4 minutes and average 8.3 minutes. The majority of cases (154 cases) by minilaparotomy required $6{\sim}10$ minutes and 67 cases $11{\sim}15$ minutes, 6 cases within 5 minutes. Maximum 30 minutes, minimum 4 minutes and average 10.4, minutes. In both groups, most of the reasons for the extra length were surgical difficulties such as thick abdominal wall, pelvic adhesion, less cooperation of patients in early period of this study. (5) Hospital stay after operation in L group required $3{\sim}4$ hours in 125 cases, $2{\sim}3$ hours in 41 cases, $4{\sim}5$ hours in 32 cases out of 250. Maximum 8 hours, minimum 1 hour and average 3.8 hours. In M group hospital stay required $6{\sim}7$ hours in 100 cases, over 7 hours in 85 cases, $5{\sim}6$ hours in 46 cases and so on. Maximum 14 hours, minimum 2 hours and average 6.5 hours. (6) The time between operation and gas passing in the majority cases of both groups, were $12{\sim}36$ hours. A veragetime 20.3 hours in L and 27.2 in M. (7) Laparoscopic sterilization coincident with induced abortion were carried out in 27 cases, laparoscopy with minilaparotomy to control for mesosalpingeal hemorrhage in 1 case. Minilaparotomy coincident with induced abortion were performed in 65 cases, D and C whit polypectomy, menstrual regulatian, and remaval of IUD in 1 case respectively. (8) In L group, 1 case of mesosalpingeal hemorrhage, 1 case of abdominal wall infection were complicated during operation. In M group, 1 case of uterine perfaration, 1 case of abdominal wall infection, 1 case of hemorrhage from omentum and 1 case of bloody vaginal discharge were complicated. No intensive medical treatment was required for those minor complications in both groups. (9) No failure has been recognized and these two sterilization techniques might be the simple, safe and the most effective method for permanent contraception at present time. There is no significant clinical defference between L and M group in this study.

  • PDF

개선된 플라즈마 공정을 이용한 Ralstonia Solanacearum 불활성화에 관한 연구 (A Study on the Ralstonia Solanacearum Inactivation using Improved Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.369-378
    • /
    • 2014
  • Effect of improvement of the dielectric barrier discharge (DBD) plasma system on the inactivation performance of bacteria were investigated. The improvement of plasma reactor was performed by combination with the basic plasma reactor and UV process or combination with the basic plasma reactor and circulation system which was equipped with gas-liquid mixer. Experimental results showed that tailing effect was appeared after the exponential decrease in basic plasma reactor. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of basic plasma process and UV process. The application of gas-liquid mixing device on the basic plasma reactor reduced inactivation time and led to complete sterilization. The effect existence of gas-liquid mixing device, voltage, air flow rate (1 ~ 5 L/min), water circulation rate (2.8 ~ 9.4 L/min) in gas-liquid mixing plasma, plasma voltage and UV power of gas-liquid mixing plasma+UV process were evaluated. The optimum air flow rate, water circulation rate, voltage of gas-liquid mixing system were 3 L/min, 3.5 L/min and 60 V, respectively. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of gas-liquid mixing plasma and UV process.

포장재에 따른 멸균품의 유효기간에 관한 연구 (Study on the Shelf Life of Sterilized Products according to Packaging Materials)

  • 장송자;정정희;최경미;김미영;박주희;정나연
    • 임상간호연구
    • /
    • 제25권3호
    • /
    • pp.333-341
    • /
    • 2019
  • Purpose: The purpose of this study was to determine the most appropriate shelf life for sterilized products according to their packaging material. Methods: Samples were prepared to target six nursing units in one general hospital in Seoul. After steam and E.O gas sterilization, sterilized product, samples were supplied to wards. Data collection was conducted for 3 months, after the expiration date of 3 months had passed for samples packaged with crepe paper and nonwoven wraps. For samples packaged with paper-plastic pouches, data collection conducted for 3 months when the expiration date of 9 months had passed. The sterilized products were collected and tested for microbial contamination. Identification of the storage environment was done as samples were collected. Results: This study confirmed that the storage environment met international standards such as CDC, except for temperature. For steam sterilized crepe paper packaging samples and steam and E.O gas sterilized for nonwoven packaging samples no contamination in all products was found for 3 months past the expiration date. However, in the E.O gas sterilized paper-plastic pouch packaging sterile samples, Gram-positive bacilli were detected in one sample from a surgical intensive care unit at 45 weeks and another sample from an operating room at 47 weeks. Furthermore, the results did not show any microorganisms for up to 52 weeks in all products. Conclusion: According to the results of this study, sterilized product packaging made with crepe paper and nonwoven wraps is better able an extended shelf life from 3 months to 6 months, reducing unnecessary costs.

Comparative study on bone regeneration between silk mat incorporated 4-hexylresorcinol and collagen membrane

  • Seok, Hyun;Jo, You-Young;Kweon, HaeYong;Baek, Dong-Heon;Kim, Seong-Gon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제34권2호
    • /
    • pp.32-37
    • /
    • 2017
  • The purpose of this study was (1) to demonstrate the anti-microbial properties of 4-hexylresorcinol (4HR) loaded silk mat and (2) comparison of bone formation between 4HR incorporated silk mat and collagen membrane. Anti-microbial properties of 4HR incorporated silk mat was done after sterilization of silk mat (autoclaving and ethylene oxide gas). For the evaluation of bone formation, bilateral bony defects (size: 8 mm) were prepared in the parietal bone of the rabbits (n=10). 4HR incorporated silk mat (size: $10{\times}10mm$) was applied on the right defect. For the comparative purpose, the same size of commercial collagen membrane was applied on the left defect. The anti-microbial properties of 4HR incorporated silk mat were maintained after sterilization process. When compared bone mineral density and bone volume, there was no statistically significant difference between groups at 4 weeks and 8 weeks after operation (p>0.05). In conclusion, 4HR incorporated silk mat could be autoclaved without concern of anti-microbial properties loss. In addition, 4HR incorporated silk mat showed similar bone regeneration to collagen membrane. Therefore, 4HR incorporated silk mat might be considered for the application of open membrane technique.

레토르트 파우치 계육 모형식품의 휘발성분 분석 (Analysis of Volatile Components of a Chicken Model Food System in Retortable Pouches)

  • 최준봉;정하열;공운영;문태화
    • 한국식품과학회지
    • /
    • 제28권4호
    • /
    • pp.772-778
    • /
    • 1996
  • 레토르트 처리시 일어나는 휘발성분 변화를 관찰하고자 닭고기 50%, 식염 1%, 닭고기 육수 49%로 구성된 모형식품을 설정하고, 가열살균에 따른 휘발성분변화를 GC (gas chromatography)로 조사하고, GC-MS (mass spectrometry)로 각 GC peak의 휘발성분을 분석하였다 살균 전, 후의 모형식품에서 NPT (Nitrogen purge and trap)방법으로 휘발성분을 포집한 후 이를 분석한 결과 총 53개 peak가 검출되었고 그 중 42개 peak를 동정하였다. 동정된 42개 peak는 aldehyde류 17종, hydrocarbon류 9종, alcohol류 8종, ketone류 7종 및 furan과 terpene이 각 1종씩이었다. 살균에 따른 휘발성분의 변화량을 비교하고, 동정된 휘발성분의 향기특성 등을 고려해 볼 때 레토르트취에 관여하는 화합물은 2-heptanone, 2-pentyl furan 및 ketone류인 것으로 추정 되었다.

  • PDF

병원내 공기오염과 물품의 항균에 대한 상태조사 (A Study on the Degree of Contamination of Air and Materials in a Hospital)

  • 차옥주
    • 한국환경보건학회지
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 1982
  • The incidence of hospital infection has been seriously increased in the general hospital in recent years. This study was performed on hospital air and materials in a General Hospital in Seoul from June to December in 1980. The results were as follows: 1. Air sampling was done in multiple strategic areas by exposing standard petridishes for 5 minutes. There was a significant difference of airborne microbe between places. ($F._{99}$ = 3.2, p < 0.01). 2. The mean colony count was 8.6$\pm$6.2 colonies / plate / 5 minutes. 3. Gram stains of colony in air sampling were Gram (+) cocci 66.5%. Gram (+) rod 18.4%, Gram (-) cocci 1.3%, Gram (-) rod 8.7% Fungus 4.5%. 4. For the evaluation of sterilization of steam sterilizer and ethylene oxide gas sterilizer, biological monitoring were done by commercial spore strip. Positive culture was obtained in 2 out of 41 tests on 3 steam sterilizers, and in 3 out of 13 tests on ethylene oxide gas sterilizer. 5. Product sampling and culture were done for 2 kinds of disinfectants and 30 sets of various operation package or dressing materials. Positive culture was obtained in one disinfectants.

  • PDF

레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구 (Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer)

  • 임윤규;양해정;김영일
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권1호
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

아세트산이 탑재된 고분자 수화젤을 이용한 이산화염소 기체의 발생 제어 (Control of Generation of Chlorine Dioxide Gas Using Polymer Hydrogels Containing Acetic Acid)

  • 이동한;이욱
    • 폴리머
    • /
    • 제37권5호
    • /
    • pp.553-556
    • /
    • 2013
  • 본 연구에서는 고분자 수화젤 비드 내부에 아세트산을 탑재시킨 후, 분무와 함께 수화젤로부터 방출된 아세트산이 아염소산나트륨과 반응하여, 저농도의 이산화염소 기체를 장시간 지속적으로 발생시킬 수 있는 장치를 개발하였다. 폴리아크릴아미드 수화젤 비드에 탑재시킨 아세트산의 함량과 부직포에 코팅한 아염소산나트륨의 함량을 변화시키면서 발생하는 이산화염소 기체의 생성량을 측정한 결과, 수화젤로부터 아세트산이 방출된 후 반응을 하기 때문에 직접반응에 의한 것보다 반응시간이 지연되어 저농도의 이산화염소 기체가 지속적으로 생성되도록 제어하는 것이 가능하였다. 이러한 결과는 본 연구가 목적으로 하는 저농도의 이산화염소를 장시간에 걸쳐서 지속적으로 생성할 수 있는 장치를 고분자 수화젤을 이용하여 구현할 수 있음을 보여준다.

히터 일체형 하이브리드 단판형 플라즈마 방전소자 (One-Plate Type Hybrid Plasma Discharge Device with Heating Element)

  • 최우진;최은혜;성형석;권진구;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.320-326
    • /
    • 2019
  • Recently, the application of atmospheric plasma technology in air filtration is increasing. Sterilization by an atmospheric plasma device is very effective. However, ozone gas, which is generated during atmospheric plasma formation, poses a hazard to human health. To reduce the ozone gas during plasma discharge, we fabricated a one-plate hybrid plasma discharge device with a heating element, which can decompose ozone gas effectively by a simple heating action. In this study, we evaluated the plasma discharge characteristics and ozone concentrations with various Ar flow rates and temperatures. With increasing Ar gas flow rate, the ozone concentration and spectrum intensity increased till an Ar gas flow rate of 60 sccm, and decreased thereafter. When discharged in high temperature, the ozone concentration and spectrum intensity decreased. Further, to evaluate the state of the treated surface under various plasma discharge and heating conditions, we measured the variation in the contact angles on the surface. Regardless of the temperature, the contact angle increased with increasing discharge voltage. However, the contact angle increased when discharged at high temperature.

GC/AED를 이용한 의료용 액화혼합가스 중 산화에틸렌 및 프레온 가스류의 몰분율 측정 (Determination of the mole fractions of ethylene oxide and freons in medical liquefied gas mixture by GC/AED)

  • 김현주;김달호;임아랑;이택홍;김진석
    • 분석과학
    • /
    • 제25권6호
    • /
    • pp.382-387
    • /
    • 2012
  • 산화에틸렌($C_2H_4O$, Ethylene oxide, EtO)은 에탄올아민 같은 공업적으로 중요한 물질이나 에틸렌 글리콜의 생산 원료 또는 살균제로 이용되는 물질이다. 산화에틸렌은 불화탄화수소를 분사제 또는 바탕가스로 하여 액화혼합가스로 제조되어 열에 약한 의료기기나 저장시설의 소독에 널리 사용되고 있다. 액화혼합가스의 생산 및 사용 시 품질관리 및 안전관리를 위해 각 성분의 몰분율을 정확히 측정할 필요가 있다. 휘발성 액체시료 중 각 기체성분들은 증기압이나 끓는점 등과 같이 물리 화학적 성질이 다르므로 몰분율 측정 시 실린더 내부의 상층에 평형을 이루고 있는 기체시료 또는 하층의 기화되지 않은 액체시료를 직접 측정기기에 주입하는 방법에 따라 측정 결과가 다를 수 있다. 본 연구에서는 액화혼합가스를 액체 또는 기체 상태로 주입할 수 있는 새로운 온라인 시료도입장치를 고안하고 GC/AED (gas chromatograph-atomic emission detector)를 사용하여 산화에틸렌과 불화탄화수소 액화혼합가스를 측정하였으며 AED의 검출특성, 기기에 주입 시 시료의 상태, 측정파장에 따른 측정결과의 정확성 및 반복성을 조사하였다.