• 제목/요약/키워드: Gas Range

Search Result 2,992, Processing Time 0.03 seconds

A Study on the Development of Low Power Automatic ON/OFF Valve System for Gas Leak Detection (가스 누출 감지를 위한 저전력 자동 ON/OFF 밸브 시스템 개발에 관한 연구)

  • Choi, Young Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.369-374
    • /
    • 2021
  • Apartment recently built in kitchen is made is made because the gas hose with built-in ways invisible inside the sink. In this case, if the gas leaks, it is a dangerous method that can accumulate inside the sink and lead to an explosion. In this study, since the hose connected between the gas range and the intermediate valve is inside the sink, it is not possible to test for gas leaks, so a valve system that can easily check for gas leaks using a pressure sensor was studied. As for the pressure measurement method, the pressure of the hose connecting the intermediate valve and the gas range was measured so that data could be collected and analyzed using the I2C communication method. In addition, the calculation of the gas pressure supplied to the home was investigated for the atmospheric pressure error for the value calculated by adding the average value of the gas gauge pressure of 22.46 mbar at the inlet of the gas meter to the atmospheric pressure. A valve system was developed to detect minute gas leaks.

Test-Retest Reliability of Paper-Pencil Test for Investigating Burner-Control Linkages of Four-Stove Gas Range

  • Kee, Dohyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.267-271
    • /
    • 2013
  • Objective: The purpose of this study is to examine the test-retest reliability of paper-pencil test for investigating population stereotype of burner-control linkages of four-stove gas ranges. Background: Much of the research on gas-range stereotype strength has been performed using the paper-pencil test. While the use of the paper-pencil tests has the advantage of collecting data in a large group of subjects against reasonable costs, concerns regarding the reliability of the paper-pencil test has also been stated. Method: Three paper-pencil tests classified by intervals of test-retest were performed, in which eight types of burner-control arrangements were investigated. Sixty eight subjects were test-retested within two weeks, 85 subjects were test-retested within four weeks and 58 subjects were test-retested three times in series with interval of two and four weeks. Results: Chi-square test showed that three intervals of test-retest including two, four and two & four weeks have not statistically significant effect on subjects' responses irrespective of eight types of burner-control linkages dealt with in this study(p>0.10). Concordance rates of subjects' responses ranged between 73.5% and 100.0% for two-week test-retest, between 67.1% and 97.6% for four-week test-retest, and between 65.5% and 100.0% for two- and four-week serial test-retest. The concordance rates were linearly correlated with proportion of subjects' responses for stereotypes of burnercontrol linkages. Conclusion: It is concluded that the paper-pencil tests for investigating gas range relevant stereotypes could reproduce reliable results compared to baseline test within interval of four weeks. Application: The results of this study would be useful as an ergonomic guideline when designing the paper-pencil tests for stereotype relevant studies.

Effect of Packaging Conditions on the Fruit Quality of Chinese Quince

  • An, Duck-Soon;Lee, Dong-Sun
    • Food Science and Biotechnology
    • /
    • v.15 no.5
    • /
    • pp.683-687
    • /
    • 2006
  • The respiration rate of Chinese quince was measured at 0, 5, 10, and $20^{\circ}C$ to determine its tolerable range of storage temperatures. Based on the measured respiration rates, plastic films covering a wide range of gas permeabilities were used for packaging and storing individual Chinese quince at 0 and $10^{\circ}C$. Chinese quince can be categorized as low respiration fruit. Higher respiratory quotients were observed at higher temperature suggesting that the tolerable temperature range for storage is $0-10^{\circ}C$. Packages containing Chinese quince wrapped in highly gas-permeable polyolefin film PD 941 attained, with progressive decreases in volume, 9.5-10.2% $O_2$ and 1.3-1.8% $CO_2$ at $0^{\circ}C$, 8.1% $O_2$ and 2.4% $CO_2$ at $10^{\circ}C$. At these levels, PD 941 could preserve the fruit at acceptable quality levels for 152 and 50 days at 0 and $10^{\circ}C$, respectively. Less gas-permeable packages built up high $CO_2$ concentrations (above 15.8%) and low $O_2$ concentrations (less than 1.8%) causing free volume expansion and eventual dark discoloration of the fruit. The storage life realized by packaging with polyolefin film PD 941 could facilitate the availability of Chinese quinces in winter and spring for medicinal or ornamental purposes in the fresh state.

Electrical and Optical Characteristics of Inductively Coupled Plasma by Ar Gas Pressure and Rf Power (Ar 가스 압력과 RF 전력에 따른 유도결합형 플라즈마의 전기적 및 광학적 특성)

  • 최용성;허인성;이영환;박대희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.560-566
    • /
    • 2004
  • In this paper, the electrical and emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma (ICP) with the variation of argon gas pressure and RF power. The RF output was applied to the antenna in the range of 5∼50 W at 13.56 MHz. The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of -100V∼+100V. When the pressure of argon gas was increased, electric current was decreased. There was a significant electric current increase from 10 to 30 W. Also, when the RF power was increased, electron density was increased. Also, the emission spectrum, Ar- I lins, luminance were investigated. At this time, the input parameter for ICP RF plasma, Ar gas pressure and RF power were applied in the range of 10∼60 mTorr, 10∼300 W, respectively. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

Condensation Heat Transfer for the R-11 Superheated Vapor with and without Noncondensable Gas (R-11의 응축열전달에 미치는 부응축가스 및 과열의 영향)

  • CHO Kwon-Ok;KUM Jong-Soo;OH HOO-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.85-93
    • /
    • 1985
  • An experimental investigation on condensing heat transfer for the Refrigerant-11 superheated vapor during condensation on the 40 mm O.D by 75 mm long horizontal tube is carried out under the various conditions of air contents as noncondensable gas, condensing pressure, and coolant temperature. The data span a refrigerant flow range from 23 to 63 kg/h and weight fractions of noncondensable gas range from 0 to $15\%$. The comparisons are made using data obtained by the authors and further data obtained from other sources. The characteristics of the condensing heat transfer of refrigerant superheated vapor with and without noncondensable gas flowing horizontally are revealed experimentally, and on the basis of the data obtained, correlations for predicting heat transfer coefficient during condensation on the tube are proposed.

  • PDF

Optimal control of continuous system using genetic algorithms (유전 알고리듬을 이용한 연속 공정의 최적 제어)

  • Lee, Moo-Ho;Han, Chonghun;Chang, Kun-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.1
    • /
    • pp.46-51
    • /
    • 1997
  • The optimal control of a continuous process has been performed using genetic algorithms(GAs). GAs are robust and easily applicable for complex and highly nonlinear problems. We introduce the heuristics 'dynamic range' which reduces the search space dramaticaly keeping the robust search of GAs. GAs with dynamic range show the better performance than SQP(Successive Quadratic Programing) method which converges to a local minimum. The proposed methology has been applied to the optimal control of the continuous MMA-VA copolymerization reactor for the production of the desired molecular wieght and the composition of VA in dead copolymer.

  • PDF

Analysis of Antioxidants in Fatty Foods Using Gas Chromatography/Mass Spectrometry (식품 중 Gas Chromatography/Mass Spectrometry를 이용한 산화방지제의 분석에 관한 연구)

  • 이정애;노동석
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.3
    • /
    • pp.210-216
    • /
    • 1997
  • The prevention of oxidative degradation in fats and oils is largely controlled by the use of synthetic phenolic antioxidants. Antioxidants, BHA: 2-&-3-tert-butyl-4-hydroxyanisol, BHT: 3,5-di-tert-butyl-4-hydroxytoluene, TBHQ: tert-butylhydroquinone, PG: propyl gallate, PTG: pentyl gallate, OG:octyl gallate, were extracted from fatty foods with hexane and from hexane layer to presaturated acetonitrile with hexane. The polar phenolic hydroxyl groups of antioxidants were silylated with MSTFA and injected to Gas Chromatography/Mass Spectrometry. The calibration plots were linear in the investigated range, 0.1~10.0 $\mu\textrm{g}$/g. The limit of detection for 6 phenolic antioxidants was 0.1 $\mu\textrm{g}$/g. Recoveries and reproducibilities from samples fortified at 1.0 $\mu\textrm{g}$/g were in the range of 70~90% and 0.5~13%, respectively. The simultaneous determination of phenolic antioxidants in fatty foods using GC/MS-SIM mode and macro program was described.

  • PDF

The Response Properties of Organic Gas for the Palmitic Acid LB films by the Effect of pH (pH변화에 대한 Palmitic Acid LB막의 유기가스 반응특성)

  • 강기호;김정명;장정수;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.317-319
    • /
    • 2000
  • We fabricated the QCM with Langmuir-Blodgett(LB) film deposited at the different subphase pH and investigated the resonant frequency response by the injection of organic gas response. In the $\pi$-A isotherms, the monolayer on the air/water interface had different limiting area per molecule and showed more condensed status as increasing the subphase pH. When palmitic acid LB film was deposited on the QCM, the resonant frequency shift was proportional to the deposited layer and had more resonant frequency shift in the case of the higher pH range as expected. In the resonant frequency for the injection of organic gas, it has been improved in the case of LB film fabricated at the lower subphase pH range and dependant upon the molecular weight of organic gas.

  • PDF

A Empirical Study on Applying Ubiquitous Technology for Gas Safety Management (U-기반 가스안전관리의 기술을 적용을 위한 실증적 연구)

  • Oh, Jeong-Seok;Choi, Kyung-Suhk;Kwon, Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.63-68
    • /
    • 2008
  • The ubiquitous technology is capable of innovating various area to constructing intelligent and network to all objects. This technology can construct network infrastructure to facilities for applying legacy industry and need to develop intelligent service that analyze context-aware through network. This paper derive and propose the introduction range of ubiquitous technology, which should be testified and analyzed network, and studied the detection and analysis of information for managing gas facilities. We investigate the current status of gas facilities and automatic reading system, testing and analyzing wireless personal area network and mobile communication by scalability, self-configuration, connection in underground. Furthermore, we propose modelization method for intelligent service and derive the introduction range for applying ubiquitous technologies for managing gas facilities.

  • PDF

Ionization of Helium Gas with a Tungsten Tip

  • Kim, Hee-Tae;Yu, Soon-Jae
    • Journal of Information Display
    • /
    • v.10 no.1
    • /
    • pp.45-48
    • /
    • 2009
  • The ionization of a helium atom was investigated as a function of gas pressure, with the use of a tungsten tip. The tungsten tip, to which the external voltage was applied, was used to generate a constant electron current. The ionization current of helium gas was measured as a function of gas pressure. Effective ionization occurred in the pressure range of 0.5-20 torr when the distance between the field emission tip and the collector was 1 cm. The ionization current was linearly proportional to the voltage that was applied to the tungsten tip.