• 제목/요약/키워드: Gas Insulated Switchgear(GIS)

검색결과 188건 처리시간 0.031초

GIS에 있어서의 과도과전압(過渡過電壓) 측정용(測定用) 센서 (A Voltage Sensor for measurement of Very Fast Transients in GIS)

  • 이복희;백용현;하촌달치;서촌준언;석정승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.297-300
    • /
    • 1990
  • The measurement of very fast transients generated by disconnecting switches in gas-insulated switchgear(GIS) have to deal with the problems such as reliability, interference pich-up, optimal design of high voitage equipments. This paper presents a new developed voltage sensor to measure the very fast transients, the basic theory of the measuring method, the design, structure of planar capacitive voltage probe are described. Finally the examples of modelling tests on an actual site GIS are discussed.

  • PDF

170kV GIS용 Rogowski coil형 CT개발 (Development of Rogowski-Coil Type CT for Application in 170kV GIS)

  • 정영환;김정배;송원표;김덕수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.479-481
    • /
    • 2001
  • Traditionally, instrument transformer of the ferromagnetic core type have been used for measuring current in GIS(Gas Insulated Switchgear). Recently, with the introduction of digital technology at the protection relay or measurement device level, the use of new current sensor can be foreseen. Current measurement by means of Rogowski coil is just one illustration of this. This paper describes the progress of development of Rogowski-coil type CT for application in 170kV GIS.

  • PDF

GIS 내부의 도체이물질에 의한 불평등 전계 해석 (Analysis of unequal electric field by metal particle in GiS)

  • 박경수;김진;이희복;고영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.531-533
    • /
    • 2000
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence So the transformer substation can be reduced the size to 1/10. Insulation method using $SF_6$ gas has a very excellent insulation characteristics for high pressure equipment but has a characteristics that insulation heredity is changed for internal unequal electric field. So analysis of electromagnetic field in GIS is very important basic data for structure design and trouble diagnosis process. In compared with established method, SNM in this paper observes variation of the electromagnetic field with real time and get result very similar to measurement. In order to know the variation of electromagnetic field distribution for transient response for time and position, variations are observed when the spacer is bonded and metal particles are moving fast.

  • PDF

광 포켈스 소자를 적용한 GIS 전단용 UHF 센서 출력신호 처리기술 개발 (A Novel method of UHF sensor signal process using Pockels sensor applicable to the diagnosis of GIS)

  • 남도희;류철휘;정승용;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.151-152
    • /
    • 2006
  • Gas Insulated Switchgear 내부에서 발생되는 부분방전 검출을 위하여 다양한 UHF센서가 이용되고 있다. 그러나 출력단의 신호크기가 극히 미약하여 다단계 증폭과정과 아날로그/디지털 신호처리 기술들이 적용되고 있으며 이로 인한 신호 왜곡이 필연적이어서 그 해결방안이 다양하게 제시되고 있다. 하나의 방안으로서 UHF 출력신호를 광 신호 형태로 전송할 수 있는 광소자와 Optical Fiber의 장점을 이용하면 기존에 상용화되어 있으나 문제를 야기 시키는 신호처리 기술 대체가 가능하다. 본 논문에서는 GIS 진단 기술개발을 위하여 자체 개발된 광 기술을 적용하여 검출된 미세신호들의 왜곡 문제점 해결에 기여하고자한다.

  • PDF

GIS 부분방전 측정용 동축형 밸런 부착 다이폴 UHF 내장형 센서 (UHF-Sensor with coaxial cable balun for Diagnosis of Insulator)

  • 박은정;조준호;김경봉;김기채;김정배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1457-1458
    • /
    • 2007
  • 본 논문은 전기에너지의 안정적인 공급을 위한 가스절연개폐장치(Gas Insulated Switchgear; GIS)의 안정성과 신뢰성을 확립하기 위해 GIS 내부 결함에 의한 사고의 발생을 미리 진단하는 절연진단용 UHF 대역($0.5\;{\sim}\;1.5$ GHz) 동축형 밸런 부착 안테나를 제안하였다. 동축형 밸런이 부착된 안테나를 GIS에 장착하였을 때 반사계수의 주파수특성을 실험치와 비교 검토하였다.

  • PDF

Lightning Impulse Breakdown Characteristic of Dry-Air/Silicone Rubber Hybrid Insulation in Rod-Plane Electrode

  • Kwon, Jung-Hun;Seo, Cheong-Won;Kim, Yu-Min;Lim, Kee-Joe
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1181-1187
    • /
    • 2015
  • Sulfur hexafluoride (SF6) gas is used widely in electric power equipment such as Gas Insulated Switchgear (GIS), Gas Insulation transmission Line (GIL), and Gas Circuit Breaker (GCB). But applications of SF6 should be restricted because SF6 gas is one of the greenhouse effect gases. To reduce use of SF6 gas, a study on eco-friendly alternative insulation medium is needed. In this paper, we investigated lightning impulse (LI) breakdown of dry-air which is attracting attention as an ecofriendly alternative gas and the LI breakdown of hybrid insulation combined with dry-air and solid insulation (Room-Temperature Vulcanizing Silicone Rubber-RTV SIR) and dry-air in inhomogeneous fields according to gap distance and pressure. The experiment results showed that the LI breakdown strength of hybrid insulation system was higher than that of dry-air insulation system. It was verified that the development of technology related to eco-friendly power apparatus compact such GIS, GCB and GIL can be used as basic research data.

25.8kV급 GIS에 Matrix System을 적용한 전력설비 최적화 연구 (A Study on Optimization of Electric Power Facilities Applied Matrix System at 25.8kV GIS)

  • 이양미;남재우;김철환
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.507-512
    • /
    • 2017
  • Recently, more electric power facilities have been miniaturized and it is noted that the facilities maintenance will be essential through operation optimization. In this paper we applied and examined the operation optimization of electric power facilities by applying Matrix system which can improve reliability to minimize outage and recover failure rapidly when blackouts happen at 25.8kV Gas Insulated Switchgear(GIS). The fundamental problem for facilities maintenance of GIS can happen due to indeterminable internal state in real time. Matrix optimization organizes action states in all containers which contain pressurized $SF_6$ Gas such as circuit breaker, disconnector switch, bus for utilizing them each area. Then, we connect it with power system to monitor and control internal state remotely in real time, and we can minimize blackout zone or outage. Considering above process, we improved stability of overall facilities.

145kV 40kA GCB용 Al 알루미늄 주물탱크 개발 (The Development of Al Casting Tank for 145kV 40kA GCB)

  • 한동영;조낙근;이근호;김정배;송원표;고희석;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1028-1030
    • /
    • 2004
  • 최근 세계시장이 Al-Casting 외함(알루미늄 주물탱크)을 적용한 GCB(Gas Circuit Breaker) 및 GIS(Gas Insulated Switchgear)를 선호하고 있으며, 이는 철재 외함에 비해 많은 이점을 갖고 있기 때문이다. 알루미늄 외함은 철재 용접형 제품에 비해 중량이 가벼워 취급 및 운반이 용이할 뿐 아니라 장기 사용 시에도 발청의 우려가 없으며, 2층 이상의 건물에 신설 또는 증설시 건물의 중량 제한에 따른 제약 조건에서 훨씬 자유롭다. 또한 Casting은 Welding형에 비해 분기부 전계 강도가 유리하고, 알루미늄은 철에 비해 열발생량이 적어 외함크기 축소가 가능하다. 또한 제작공정이 철재 용접외함에 비해 단순하고 대량생산에 유리하다. 이로 인해 외함이 표준화되고 GIS 모듈화가 완성되면 기종별 Series화하여 대량생산 체제 구축에 유리하게 된다. 점진적인 인건비 상승으로 용접형 외함의 단가상승이 예상되며, GCB의 경우 Al Casting형이 원가면에서도 유리하다. 이에 당사 GCB 및 GIS 제품 경쟁력 향상 및 수출시장 적극공략을 목적으로 현행 GCB 및 GIS 철재 용접형외함을 알루미늄 Casting 외함으로의 변경, 개발을 실시하였다. 본 연구에서는 Al Casting 외함을 개발하기 위한 일련의 과정에 대해 소개한다.

  • PDF

초고압 GCB용 Al 알루미늄 주물탱크 개발 (The Development of Al Casting Tank for Ultra High Voltage GCB)

  • 양대일;한동영;서경보;김정배;송원표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1330-1332
    • /
    • 2005
  • 최근 세계시장이 Al-Casting 외함(알루미늄 주물탱크)을 적용한 GCB(Gas Circuit Breaker) 및 GIS(Gas Insulated Switchgear)를 선호하고 있으며, 이는 철재 외함에 비해 많은 이점을 갖고 있기 때문이다. 알루미늄 외함은 철재 용접형 제품에 비해 중량이 가벼워 취급 및 운반이 용이할 뿐 아니라 장기 사용 시에도 발청의 우려가 없으며, 2층 이상의 건물에 신설 또는 증설시 건물의 중량 제한에 따른 제약 조건에서 훨씬 자유롭다. 또한 Casting은 Welding형에 비해 분기부 전계 강도가 유리하고, 알루미늄은 철에 비해 열발생량이 적어 외함크기 축소가 가능하다. 또한 제작공정이 철재 용접외함에 비해 단순하고 대량생산에 유리하다. 이로 인해 외함이 표준화되고 GIS 모듈화가 완성되면 기종별 Series화하여 대량생산 체제 구축에 유리하게 된다. 점진적인 인건비 상승으로 용접형 외함의 단가상승이 예상되며, GCB의 경우 Al Casting형이 원가면에서도 유리하다. 이에 당사 GCB 및 GIS 제품 경쟁력 향상 및 수출시장 적극공략을 목적으로 현행 GCB 및 GIS 철재 용접형외함을 알루미늄 Casting 외함으로의 변경, 개발을 실시하였다. 본 연구에서는 Al Casting 외함을 개발하기 위한 일련의 과정에 대해 소개한다.

  • PDF

이동격자를 이용한 72.5kV${\sim}$800kv 초고압 차단기 유동해석 (CFD Analysis of 72.5kV${\sim}$800kV GIS with Moving Grid)

  • 윤자홍;최병화;이기헉;윤치영;고경석;민병수;박일석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.799-801
    • /
    • 2002
  • To develop GIS (Gas Insulated Switchgear), prediction of the flow field including pressure in GIS is very important. The transport phenomena in GIS including arc is also being studied in these days. In this study, to predict the arc behaviour for GIS with voltage rating up to 800kV developed by HHI (Hyundai Heavy Industries Co. Ltd.), the analysis of flow and electric field in GIS were investigated. To simulate the compressible flow in GIS, the CFX, commercial CFD code, was used. The movement of the piston and the electrode of the GIS was simulated with moving grid method, which was superior to the method of varying the property of cells in the aspect of accuracy and convergence of solution. The calculated maximum pressure within the puffer cylinder was matched with experimental data within 5% error. Also, the oscillation of pressure in GIS after the movement of electrode was well predicted.

  • PDF