• 제목/요약/키워드: Gas Insulated Switchgear(GIS)

검색결과 188건 처리시간 0.031초

금속 이물질이 에폭시 절연물의 절연파괴에 미치는 영향 (Effects of Metal Particle on Dielectric Breakdown of Epoxy Insulation)

  • 장윤기;이동원;김정배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.207-208
    • /
    • 2007
  • Epoxy resin insulators show a lot of advantages for electrical power apparatus. Because epoxy resin provide electrical and mechanical characteristic which is excellent, it is desirable to apply epoxy resin as a spacer and post insulation in Gas Insulated Switchgear (GIS). In this study, we have investigated the influence of surface electric field attached particle contaminated spacer surfaces under SF6 gas. Also, we performed analysis of electric field. As a result, when the particle was attached on spacer, we found out a surface electric field of characteristics.

  • PDF

SiO2와 Al2O3를 충진재료로 사용하는 초고압 GIS용 에폭시 절연물 베리어의 전기적 및 기계적 특성에 관한 연구 (A Study on Electrical and Mechanical Properties of Epoxy Insulation Barrier for High Voltage GIS Using a Filler of SiO2 and Al2O3)

  • 서왕벽;배동호
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.379-383
    • /
    • 2015
  • Some insulating materials are organized and analyzed with variables to obtain the optimized profile of encapsulated three phase of epoxy barrier which is applied to gas compartment and supporting conductors for high voltage GIS (gas insulated switchgear). The high voltage GIS is used in electrical power system and operating reliability. In this paper, optimization possibility of barrier shape including both electrical insulation performance and mechanical strength, premised on that condition minimizing volume and light weight should be kept for high voltage GIS, could be achieved by analysis simulation. As a result, filling material which is lower permittivity such as $SiO_2$ instead of $Al_2O_3$ properly to the epoxy material, can be improved to increase the electrical insulation performance and mechanical strength for an optimized profile barrier of a high voltage GIS.

Electrical and Mechanical Properties of Epoxy/Micro-sized Alumina Composite and the Effect of Nano-sized Alumina on Those Properties

  • Park, Jae-Jun;Shin, Seong-Sik;Yoon, Chan-Young;Lee, Jae-Young;Park, Joo-Eon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.260-263
    • /
    • 2015
  • Epoxy/micro-sized alumina composite was prepared and the effects of alumina content on the electrical and mechanical properties were investigated in order to develop an insulation material for gas insulated switchgear (GIS). Nano-sized alumina (average particle size: 30 μm) was also incorporated into the epoxy/micro-sized alumina composite. An electrical insulation breakdown strength test was carried out in sphere-sphere electrodes and the data were estimated by Weibull statistical analysis. Tensile strength was measured at a crosshead speed of 10 mm/min using a universal testing machine. Alumina content was varied from 0 wt% to 70 wt%.). As micro-sized alumina content increased, insulation breakdown strength increased until 40 wt% alumina content and decreased after that content. The tensile strength of a neat epoxy system was 82.2 MPa and that value for 60 wt% alumina content was 91.8 MPa, which was 111.7% higher than inthe neat epoxy system. The insulation breakdown strength of micro-sized alumina (60 wt%)/nano-sized alumina (1 phr) glycerol diglycidyl ether (GDE) (1 phr) composite was 54.2 MPa, which was 116% higher than the strength of the system without nano-sized alumina.

초고압 GCB의 차단성능 검증을 위한 유동해석 (Fluid Analysis for Verifying Interrupting Capability of UHV GCB)

  • 김두성;서경보;송원표;정영환;김덕수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.19-21
    • /
    • 2002
  • Recently, it has become more competitive to take larger market share among domestic companies manufacturing high-power apparatus. Unfortunately, the size of total market in this field is being smaller than before because the business of transmission and distribution of electric power is being shifted from government control to private management. To save this situation, we are trying to develop new high-voltage Gas Insulated Switchgear for export such as 245kV GIS and 300kV GIS. It is very important to make GIS compact size to have international competitiveness against European companies. By reducing GIS's dimensions same as 170kV class, we expect to launch abroad successfully. Many factors should be considered to achieve good performance during short-circuit making-breaking. Analysis on cold gas flow is one method widely used to evaluate small-current interruption. Through this analysis, we can examine the dielectric characteristics at the weak points in the circuit-breaker. In this paper, we describe the results of cold-gas flow analyses on 245kV and 300kV circuit-breakers.

  • PDF

금속입자 오손시 $SF_6$가스의 절연파괴특성 (Breakdown Characteristics of $SF_6$ Gas under Particle Contaminated Conditions)

  • 김민규;문인욱;김익수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.465-468
    • /
    • 1995
  • The gas-insulated switchgear(GIS) has made high-reliability, high-safety, compact substations possible by using $SF_6$ gas. They are likely to be further developed toward higher voltages and targer capacities, along with greater compactness and lower cost. Although $SF_6$ gas has excellent insulation performance, breakdown voltages are reduced by the conducting particles. Thus, extensive studies have been made on the breakdown characteristics of $SF_6$ gas in particle contaminated conditions. Experiments were carried out for fired particle and free particle in a coaxial electrode system with DC and AC voltages. This paper represents the experimental results of the processes involved in electrical breakdown in compressed $SF_6$ gas, where breakdown is initiated by conducting particles.

  • PDF

An Application of the Novel Techniques Detecting Partial Discharge Employable to GIS Using Optical Sensor

  • Ryu, Cheol-Hwi;Jung, Seung-Yong;Koo, Ja-Yoon;Yeon, Man-Seung
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.396-400
    • /
    • 2007
  • A novel technique has been proposed and related experimental works have been performed in order to detect the partial discharges and the location of the possible defects introduced into the Gas Insulated Switchgear. For this purpose, a prototype HY Pockels sensor has been developed and then employed in order to investigate its field applicability for finding the location of the defects using a 170kV GIS mock-up. Our proposed sensor enables us to measure the electric field variation due to the PD occurrence. In addition, the different PD patterns are observed, which might be dependant on the location and the distance of the sensor with respect to the PD source. Throughout this work, its linear response has been proved to be admissible as a function of the applied voltage. And also the position of the PD source might be distinguished by comparing the PD patterns.

GIS PD검출을 위한 초광대역 UHF 커플러의 비교 연구 (A comparative study on UWB UHF couplers for GIS PD detection)

  • 이상화;최재구;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.207-210
    • /
    • 2003
  • 가스절연개폐장치(Gas-Insulated Switchgear, GIS) 내부에서 발생하는 부분방전(Partial Discharge, PD) 신호는 1ns이하의 상승시간(rising time)을 가지므로, 이 신호를 효과적으로 측정하기 위해서는 초광대역(Ultra Wide Band, UWB)특성을 갖는 커플러가 필요하다. 본 논문에서는 이러한 UWB 특성을 구현하기 위해, 대수주기 톱니형 평면 안테나(log-periodic toothed planar antenna)와 등각 스파이럴 패치안테나(equi-angular spiral patch antenna)형태의 두 가지 초광대역 UHF 커플러를 설계 제작하였다. 제작한 커플러들의 특성을 파악하기 위해 안테나의 급전부에, 자체 설계한 매칭 회로인 발룬(balun, balance to unbalance)을 장착하여, 반사계수, 모의펄스에 의한 검출신호, 스펙트럼 둥을 측정하였다.

  • PDF

GIS 절연진단용 Cavity 안테나 센서의 특성 연구 ((The Characteristics Study of Cavity Antenna Sensor for GIS Insulation Diagnosis)

  • 이창훈;이창욱;최은혁;김정배;김기채;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.424-426
    • /
    • 2007
  • 본 연구에서는 UHF 대역의 측정이 가능한 Cavity 안테나를 이용하여 절연진단기술에서의 적용가능성을 검토해 보았다. 제안된 안테나는 유전체 손실이나 급전라인의 손실이 없는 공기를 매질로 하므로, 고출력에 적합하며 고효율을 가진다. 또한 제작이 용이한 구조를 가지므로 대량 생산 시 많은 장점올 가질 것으로 기대된다. 시뮬레이션을 통하여 Cavity 안테나가 0.3 ${\sim}$ 10[GHz] 대역에서는 -10[dB]이하의 Return loss값을 가지는 측정주파수 대역이 약 2.7 ${\sim}$ 10[GHz]로 나타났으며, 0.3 ${\sim}$ 2.5[GHz]의 대역일 경우는 측정 주파수 대역이 약 0.7 ${\sim}$ 2.5[GHz]으로 나타남으로써 대표적인 전력기기인 GIS(Gas Insulated Switchgear : 가스절연개폐장치)에서 UHF 대역을 이용한 절연진단기술에서 사용하는 주파수 대역에서 사용이 가능함을 확인할 수 있었다.

  • PDF

25.8 kV GIS에서 전자기파 부분방전신호 감쇠특성 측정방법 비교 (Comparison of The Attenuation Measurement Methods for Electromagnetic Partial Discharge Signal in 25.8 kV Gas Insulated Switchgear)

  • 구선근;한기선;곽주식;주형준;정문규
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1281-1287
    • /
    • 2015
  • We report the characteristics and differences of two types of attenuation measurement methods for electromagnetic partial discharge signal in GIS. The pulse method is to measure the attenuated waveforms in time domain and coverts them into frequency domain to get the attenuation spectra of given GIS section. This method simulates the real partial discharge signal. The frequency swept continuous wave method can obtain attenuation spectra directly so that it gives attenuation with low noise floor and simplicity. We show that both methods are effective and exchangeable because the attenuation results measured by two methods have similar trends

전력설비 안전성 확보를 위한 GIS(가스절연개폐장치) 검사수행 절차 및 방법 (The Inspection Procedure and Method of GIS to Guarantee the Safety of Power Facility)

  • 박준성;황광수;김진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.361-364
    • /
    • 2015
  • 본 논문은 전기사업법 제61조의 공사계획인가 및 신고대상인 차단기에 대하여 동법 제63조에 의거해 실시하는 사용전검사의 항목 및 검사수행 방법에 대하여 서술하였다. 차단기는 전력계통을 이상전압에서 보호하기 위한 밀폐형 개폐장치로서 전기사업용 전기설비인 변전소에 설치되는 차단기는 대부분 GIS(Gas Insulated Switchgear)화 되고 있는 실정이다. GIS는 정상전류의 차단, 설비사고의 억제 및 파급사고 확산방지에 중추적인 역할을 수행하고 있기 때문에 그 중요성은 더욱 더 높아지고 있다고 볼 수 있다. 이에 핵심 전력설비인 GIS의 사용전 검사항목 및 검사수행 방법을 고찰함으로써 안정적인 전력공급과 전력계통의 신뢰도 제고에 기여하고자 한다.

  • PDF