• Title/Summary/Keyword: Gas Hazard

Search Result 262, Processing Time 0.024 seconds

Development of Type 4 Composite Pressure Vessel by using PET Liner for Self-contained Breathing Apparatus (PET 라이너를 적용한 공기호흡기용 타입 복합재료 4 압력용기 개발)

  • Cho, Sung-Min;Lee, Seung-kuk;Cho, Min-sik;Lyu, Sung-ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.164-169
    • /
    • 2018
  • In this study, we solved the human hazard problem of aluminum liner by applying plastic PET liner which is widely used as a material for food and beverage containers in the market. In order to reinforce dome area by using low strength / high elongation plastic liner, The aluminum boss was covered on the plastic liner surface. In order to predict the performance of the developed product, the structural analysis was carried out by applying the three - dimensional laminated solid element, and the soundness of the product was verified through the prototype performance test.

Hazard Evaluation of Gas Processes Using a Multi-distinction Equipment Screening Algorithm (다중판별 장치 스크리닝 기법을 이용한 가스공정의 위험성 평가)

  • Yoon En Sup;Park Jeong Su;Ahn Sung Joon;Han Kyounghoon;Yoon Jong Phil;Kim Ku Hwoi;Shin Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.1-9
    • /
    • 2003
  • A Multi-distinction Equipment Screening Algorithm (MESA) is proposed. It selectively integrates Dow's F&EI as its process hazard index technique and ESA (Equipment Screening Algorithm) as qualitative hazard classification technique, and retrieves a detailed list of hazardous equipments with the total hazard indices of those equipments. The inherent expert system, which includes the accident scenarios of the equipments and processes and experts' views of them, narrows further down the list of hazardous equipments and recommends only the most notable candidates. Through the case study of distinguishing the hazardous ranking of the equipments of the LPG underground storage process, using the expert system or not, the applicability of MESA has been validated. Taking the characteristics of the process equipments with hazardous ranking in the point of process intrinsic safety, this proposed algorithm would contribute to providing engineers or managers with information on constructing safely devices and mitigation devices and on scheduling emergency response planning.

  • PDF

The Experimental Study on the Toxic Gases Released from the Floor Finishing Materials in Entertainment Service Industry Buildings (다중이용시설 바닥마감재의 연소가스 독성평가에 관한 실험 연구)

  • 강성동;이창우;현성호;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.14-21
    • /
    • 2002
  • The several floor finishing materials that widely used in entertainment service industry buildings were evaluated according to the method of NES 713. Also, toxic gases of floor finishing materials in combustion without air flow rate were checked as concentration of fire gases variation according to time using gas analyzer. We had estimated the smoke hazard of floor finishing materials in fire. As results of gas analyses using the method of NES 713, toxic index of samples was estimated range of 2~9.7. Therefore, a large amount of toxic gases will release from a floor finishing materials fire and connoted great smoke hazard in fire.

Hazard Evaluation on Fire and Explosion Characteristics of Resorcinol (레조르시놀의 화재·폭발 위험성 평가)

  • Lee, Keun Won;Choi, Yi Rac;Song, Se Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.45-50
    • /
    • 2013
  • Resorcinol is widely used as a wood, tire adhesives, and a raw material of synthetic dye. This material with white crystals at room temperature, the particulates in the air can form explosive mixtures. It is known to be an explosion hazard when exposed to heat in a confined space. The study was evaluated fire and explosion characteristics of the resorcinol through thermal analysis, thermal stability, dust explosion characteristics, and the minimum ignition energy. From this study, it can be used to provide a safety information in the using and handling process of the resorcinol.

THERMAL AND SMOKE MEASUREMENTS OF VEHICLE FIRES Establishing practical large-scale experiment for vehicle fires

  • Kim, Jeong-Hun;Kim, Hong;Lee, Bog-Young;Lee, Chang-Seop
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.335-342
    • /
    • 1997
  • Experiments were conducted to evaluate the hazard risks of vehicle fires. Sensors were strategically placed in passenger cars to determine the temperature, propagation rate and direction of flame. The life safety hazard evaluations such as smoke and gas analysis were included. An important ignition position was performed in the engine compartment. The effects of different ignition positions and the opening of door glasses were also reviewed. The experimental results indicate that the maximum temperature when a vehicle burns varies commonly from 90$0^{\circ}C$ -100$0^{\circ}C$. The flame reaches in the face of a driver about 6-7minutes and the windshield glass breaks about 10 minutes after the ignition in the engine compartment of vehicle. And the smoke and gas concentrations reached the limit of human inhalation after 13-14 minutes. Especially the concentrations of carbon monoxide exceeded the TWA(50 ppm) during short time after ignition in cases of all experiments.

  • PDF

Effect of Electron Irradiation on the Properties of GZO Thin Film and its Gas Sensor Application (전자빔 표면 조사에 따른 GZO 박막의 물성과 가스센서 응용 연구)

  • Kim, Dae-Il
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.3
    • /
    • pp.140-143
    • /
    • 2011
  • In this work, Ga doped ZnO (GZO) films were prepared by radio frequency (RF) magnetron sputtering without intentional substrate heating on glass substrate and then the effect of the intense electron irradiation on structural and electrical properties and the NOx gas sensitivity were investigated. Although as deposited GZO films showed a diffraction peak for ZnO (002) in the XRD pattern, GZO films that electron irradiated at electron energy of 900 eV showed the higher intense diffraction peaks than that of the as deposited GZO films. The electrical property of the films are also influenced with electron's energy. As deposited GZO films showed the three times higher resistivity than that of the films irradiated at 900 eV In addition, the sensitivity for NOx gas is also increased with electron irradiation energy and the film sensor showed the proportionally increased gas sensitivity with NOx concentration. This approach is promising in gaining improvement in the performance of thin film gas sensors used for the detection of hazard gas phase.

A Study on application of F-N curve to OCA (장외영향평가 F-N curve 적용에 관한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.31-37
    • /
    • 2018
  • The distrust about chemical plant safety have been increased by occurring the major industrial accidents. Chemical plants have become more and more enlarged and sophisticated to increase production amount and decrease cost. So hazard of industrial accidents also have been increased. In this situation, quantitative risk assessment is activated by introducing OCA(Off-site Consequence Analysis). So it is possible to analyze the objective hazard of chemical plant. Currently OCA focus on the end point of hazardous area by fire/explosion/dispersion. But in this case, it is possible to analyze the industrial accident effect to near the chemical plant but hard to consider the actual hazard by frequency and population density. This study analyzes the validity about application of F-N curve to OCA by compare end point with F-N curve about accident.

Is HAZOP a Reliable Tool? What Improvements are Possible?

  • Park, Sunhwa;Rogers, William J.;Pasman, Hans J.
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.1-20
    • /
    • 2018
  • Despite many measures, still from time to time catastrophic events occur, even after reviewing potential scenarios with HAZID tools. Therefore, it is evident that in order to prevent such events, answering the question: "What can go wrong?" requires more enhanced HAZID tools. Recently, new system based approaches have been proposed, such as STPA (system-theoretic process analysis) and Blended Hazid, but for the time being for several reasons their availability for general use is very limited. However, by making use of available advanced software and technology, traditional HAZID tools can still be improved in degree of completeness of identifying possible hazards and in work time efficiency. The new HAZID methodology proposed here, the Data-based semi-Automatic HAZard IDentification (DAHAZID), seeks to identify possible scenarios with a semi-automated system approach. Based on the two traditional HAZID tools, Hazard Operability (HAZOP) Study and Failure Modes, Effects, and Criticality Analysis (FMECA), the new method will minimize the limitations of each method. This will occur by means of a thorough systematic preparation before the tools are applied. Rather than depending on reading drawings to obtain connectivity information of process system equipment elements, this research is generating and presenting in prepopulated work sheets linked components together with all required information and space to note HAZID results. Next, this method can be integrated with proper guidelines regarding process safer design and hazard analysis. To examine its usefulness, the method will be applied to a case study.

Structural Response of Offshore Plants to Risk-Based Blast Load

  • Heo, YeongAe
    • Architectural research
    • /
    • v.15 no.3
    • /
    • pp.151-158
    • /
    • 2013
  • Offshore oil and gas process plants are exposed to hazardous accidents such as explosion and fire, so that the structural components should resist such accidental loads. Given the possibilities of thousands of different scenarios for the occurrence of an accidental hazard, the best way to predict a reasonable size of a specific accidental load would be the employment of a probabilistic approach. Having the fact that a specific procedure for probabilistic accidental hazard analysis has not yet been established especially for explosion and fire hazards, it is widely accepted that engineers usually take simple and conservative figures in assuming uncertainties inherent in the procedure, resulting either in underestimation or more likely in overestimation in the topside structural design for offshore plants. The variation in the results of a probabilistic approach is determined by the assumptions accepted in the procedures of explosion probability computation, explosion analysis, and structural analysis. A design overpressure load for a sample offshore plant is determined according to the proposed probabilistic approach in this study. CFD analysis results using a Flame Acceleration Simulator, FLACS_v9.1, are utilized to create an overpressure hazard curve. Moreover, the negative impulse and frequency contents of a blast wave are considerably influencing structural responses, but those are completely ignored in a widely used triangular form of blast wave. An idealistic blast wave profile deploying both negative and positive pulses is proposed in this study. A topside process module and piperack with blast wall are 3D FE modeled for structural analysis using LS-DYNA. Three different types of blast wave profiles are applied, two of typical triangular forms having different impulse and the proposed load profile. In conclusion, it is found that a typical triangular blast load leads to overestimation in structural design.

Pyrolysis Hazard for Nano and Micro-sized Aluminium Dusts (알루미늄 나노 및 마이크로 입자의 열분해 위험성)

  • Han, Ou-Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.75-80
    • /
    • 2015
  • Aluminum dusts, from micro to nano-scale, are widely used in various applications such as propulsion and pyrotechnic compounds because of high burning rate. In this study, the pyrolysis hazard of aluminum dusts with different median size (sized by 70 nm, 100 nm, $6{\mu}m$, $15{\mu}m$) were investigated experimentally. The thermal decomposition characteristics of aluminum dusts with the variation of heating rate were investigated using TGA (Thermo gravimetric analysis) and was estimated the minimum ignition temperature from temperature of weight gain in nano and micro-sized aluminum dusts with different diameter. In the same condition of heating rate, the temperature of weight gain in aluminum dust layers increased with increasing of particle size and increased with increasing of heating rates in air. From the results, it was estimated that the pyrolysis hazard of aluminum dusts decrease with increasing of mean diameter.