• 제목/요약/키워드: Gas Gun

검색결과 452건 처리시간 0.029초

N2 Gas 유량에 따른 TiNOx/Ti/Al 흡수율 변화 (Absorption Rate Variation of TiNOx/Ti/Al Films Depending on N2 Gas Flow Rate)

  • 김진균;장건익;김현후
    • 한국전기전자재료학회논문지
    • /
    • 제28권2호
    • /
    • pp.75-79
    • /
    • 2015
  • Ti was deposited on the Al substrate using DC magnetron sputtering with changing the $N_2$ gas for the possible application of a solar absorbing layer. $N_2$ gas ranged from 50 to 75 sccm was systematically applied in the 5 sccm interval and the variation of the absorption rate was investigated. Microstructural examination and elemental analysis indicate that Ti was reacted with $N_2$ gas and formed $TiNO_x$ compound. As compared with the film without any exposure of $N_2$ gas, absorption rate improved by more than 20%. Typically the average absorption of $TiNO_x$ fim with 65% of $N_2$ gas was about 99% in the visible range, and the average absorption was more than 90% in the infrared absorption region respectively.

LPG 누출 및 가스센서 3D Mapping을 통한 가스유동현상 분석 (Analysis of Gas Flow Behavior with Experiments for LPG releasing and 3D Mapping of Gas Sensor)

  • 김정환;이민경;길성희;이진한;조영도;문종삼
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.45-55
    • /
    • 2017
  • 대부분의 가연성가스의 누출 및 화재/폭발 등의 실험은 큰 위험성이 있으며 실험을 진행할 수 있는 부지 선정에 큰 어려움이 있어 가급적 전산유동해석(CFD) 등의 간접적 방법을 많이 활용하였다. 그러나 2016년 10일 강원도 영월군에 에너지안전실증연구센터가 개소함에 따라 대규모/고압/초저온 등의 실험 뿐아니라 소규모 가연성 가스의 누출 및 검지 실험이 가능하게 되어 본 실험을 계획하였다. 본 실험에서는 가스센서를 교정하고 가스가 누출될 공간에 배치 후 LP가스를 누출시켜 가스센서에 검지된 값을 Contour map으로 가시화하였다. 또한 동일 조건으로 해석한 전산유동해석 결과값과 비교하여 LEL 25% 값의 실제 누출(28s, 최대 3.7m)의 차이점에 대해 분석하였다.

지중 매설 가스 배관의 열차 주행 속도에 따른 진동 속도 특성 (Vibration Velocity Response of Buried Gas Pipelines according to Train Speed)

  • 김미승;선진선;김건;김문겸
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.561-566
    • /
    • 2008
  • Recently, because of development of the high speed train technology, the vibration loads by train is significantly increased ever than before. This buried gas pipelines are exposed to both repeated impact loads, and, moreover, they have been influencing by vibration loads than pipeline which is not located under vehicle loads. The vibration characteristic of pipeline is examined by dynamic analysis, and variable is only train speed. Since an effect of magnitude of vibration loads is more critical than cover depth, as increasing the train speed, the vibration speed of buried pipelines is also increased. The slope of vibration velocity is changed by attenuation of wave, at train speed, 300 km/h. From the analysis results, the vibration velocity of pipelines is satisfied with the vibration velocity criteria which are established by Korea Gas Corporation. The results present operation condition of pipelines under rail loads has fully sound integrity based on KOGAS specification.

  • PDF

고분자 연료전지의 다공성층 내에서의 액상수분 이동에 관한 공극-네트워크 해석 연구 (Pore-network Study of Liquid Water Transport through Multiple Gas Diffusion Medium in PEMFCs)

  • 강정호;이상건;남진현;김찬중
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.46-53
    • /
    • 2011
  • Water is continuously produced in polymer electrolyte membrane fuel cell (PEMFC), and is transported and exhausted through polymer electrolyte membrane (PEM), catalyst layer (CL), microporous layer (MPL), and gas diffusion layer (GDL). The low operation temperatures of PEMFC lead to the condensation of water, and the condensed water hinders the transport of reactants in porous layers (MPL and GDL). Thus, water flooding is currently one of hot issues that should be solved to achieve higher performance of PEMFC. This research aims to study liquid water transport in porous layers of PEMFC by using pore-network model, while the microscale pore structure and hydrophilic/hydrophobic surface properties of GDL and MPL were fully considered.

  • PDF

RCGA와 퍼지기법을 이용한 선박용 가스터빈 엔진의 속도제어 (Speed Control of Marine Gas Turbine Engines Using a RCGA and Fuzzy Technique)

  • 소명옥;이윤형;진강규;정병건;강인철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.274-280
    • /
    • 2005
  • The system parameters of gas turbine engine tend to change remarkably in real operating condition. It means that operators have to consider environment and suitably control fuel flow. The conventional PID controller, however, can not guarantee good control performance in the aspect of system parameter change. This paper, therefore, proposes a scheme for integrating PID control and fuzzy technique to obtain the good performance of gas turbine engine speed control on the whole operating range. The effectiveness of the proposed fuzzy PID controller is verified through computer simulation.

  • PDF

AC 플라즈마 디스플레이 패널에서의 최적 구동 파형 및 최적 가스 흔합비에 관한 연구 (A study on optimal drive waveform and optimal gas mixing ratio of Plasma Display Panel)

  • 최훈영;박헌건;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1721-1723
    • /
    • 1997
  • In AC Plasma Display Panel(PDP), serious problems are low radiation brightness and very high discharge voltage. To solve these problems, it is necessary to obtain optimal frequency of drive waveform and optimal gas mixing ratio. This paper presents firing voltage and sustain voltage as frequency of waveform and gas mixing ratio, and proposes optimal frequency of drive waveform and optimal gas mixing ratio.

  • PDF

비열플라즈마에 의한 수소가스발생에 미치는 수표면 진통효과 (The effect of vibration of the water surface for hydrogen gas generation by plasma electrical discharge)

  • 김종석;박재윤;정장근;김태용;이재동;고희석;이현우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.115-119
    • /
    • 2004
  • This paper is investigated about the effect of vibration of the water surface for hydrogen gas generation by non-thermal plasma. The vibration of the water surface is more powerful with increasing applied voltage. In this experimental reactor which is made of multi-needle and plate, the maximum acquired hydrogen production rate is about 6.8[ml/sec]. Although the generation of hydrogen gas is increased with elevating time, it is saturated after specific time due to the volume of reactor and the saturation of taylor cone.

  • PDF

가변 파장형 적외선 센서를 이용한 변압기 결함 진단 (Fault Analysis of Transformer using Tunable Infrared Gas Sensors)

  • 이근호;이승환
    • 센서학회지
    • /
    • 제32권1호
    • /
    • pp.55-61
    • /
    • 2023
  • The objective of this study is to determine the concentrations of mixed gases by establishing a diagnosis method of a transformer using tunable-wavelength optical infrared sensors. Absorption of infrared light by methane, acetylene, and ethylene gases injected is measured from the outputs of the infrared sensors. Regression analysis equations of the gas concentrations are acquired from their respective measured absorption. The obtained concentrations are as follows: -3-9 % errors above 600 ppm(methane), 3 % errors above 1200 ppm(acetylene), and 10 % errors above 500 ppm(ethylene). The concentration inference equations obtained using the individual gases are applicable when the absorption wavelength bands do not overlap. The results of the fault analysis of a transformer using the Duval triangle method and the tunable infrared gas sensors are as follows: temperature faults with -1-1% errors and energy faults with -7-7 % errors.

수산소 혼합가스를 이용한 선상가열 특성 (The Characteristics of Line Heating Using Hydrox Gas)

  • 김홍건;곽이구
    • 한국생산제조학회지
    • /
    • 제20권4호
    • /
    • pp.407-411
    • /
    • 2011
  • The technology of line heating has evolved in various methods. Among them, fossil fuels like ethylene gas and LPG(Liquid Petroleum Gas) are widely used due to their simple utility. In the meantime, the technology implementing high frequency for line heating has also been developed continually, but its manufacturing technology or application includes lots of problems by now. One of the main characteristics of line heating using conventional technolob'Y is the quenching effect followed by heating process. On the other hand, hydrox gas which is mixed by hydrogen and oxygen is a prominent candidate for an application without above shortcomings. Especially, it is found that line heating using hydrox gas is tremendously effective taking low cost as well as low noise. In this paper, a small cell with high efficiency which can minimize installing space is developed to deal with the problem installing in narrow place. Experiments to prove the validation, efficiency and effectiveness is carried out by characterizing in the line heating of steel. It is found that the energy saving of using hydrox gas for line heating is significant and that the deviation performance is reduced by 78~89%. Furthermore, the noise is also reduced as amount of 18.3% though the heating time is not too different.

Hydrox Gas 절단과 LPG 절단의 열적특성에 관한 연구 (A Study on the Thermal Characteristics of LPG and Hydrox Gas Cutting)

  • 김홍건;곽이구
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.301-305
    • /
    • 2010
  • Cutting procedures where qualities are determined by various demand factors largely influences shipbuilding productivity. Particularly, defects in cutting shapes and cutting surface results in delay for post shipbuilding stages such as in welding and assemblage lines which could become factors for reduced economic viability of the project. Existing cutting procedures utilize fossil fuels such as propane or ethylene as the main fuel component and these methods applied particularly to ship plate cutting gives relatively slow cutting speed and generates large quantities of harmful and sometimes poisonous polluting fumes of which warrants an urgent need to look for alternative cutting methods. Recent introduction of hydrox gas generated by electrically dissociating water into hydrogen and oxygen components to be utilize as an alternative cutting fuel has resulted not just in visible improvement on cutting quality and speed over the existing methods but it has also been welcomed as an environmentally friendly clean fuel source. This paper has been prepared to serve as the basis for accommodating this environmentally friendly hydrox gas cutting method into actual working environment by observing and recording hydrox gas cutting thermal characteristics.