• Title/Summary/Keyword: Gas Discharge

Search Result 1,514, Processing Time 0.028 seconds

Analysis of Cast Iron by Glow Discharge Emission Spectrometry (글로우 방전/방출분광분석법에 의한 주철시료의 분석)

  • Cho, K.H.;Woo, J.C.;Han, M.S.
    • Analytical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.297-305
    • /
    • 1993
  • Generally, it is difficult to analyze cast iron samples with spark discharge emission spectrometry since the content of carbon in these samples is high as a few percent. The cast iron samples were analyzed with the developed glow discharge emission spectrometer composed of glow discharge emission source and polychromator. The discharge condition of glow discharge lamp(GDL) has been optimized by variation of Ar gas pressure, discharge voltage and discharge time. Under the optimum conditions obtained in this work, relationships between the measured emission intensities and concentration of two types of cast iron standard samples(BAS, LECO) were investigated. Most of elements(Mn, Si, P, S etc.) showed the good linearity in one calibration curve. And the carbon showed slightly the systematic difference according to the type of standard samples.

  • PDF

Analysis of Medium Effect by Gas Pressure and Gap at Surface Discharge of Dry Air (건조공기의 연면방전에서 가스압력과 극간거리에 따른 매질효과분석)

  • Lim, Dong-Young;Min, Gyeong-Jun;Park, He-Rie;Choi, Eun-Hyeok;Choi, Sang-Tae;Bae, Sung-Woo;Rhee, Sang-Bong;Park, Won-Zoo;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.86-92
    • /
    • 2013
  • In studies on an alternative insulating gas of $SF_6$ gas, the section of the alternative gas and an insulation technique to improve its low dielectric strength have been reported, but very few attempts have been made at the dependence of a gas pressure and a gap as well as the medium effect in the alternative gas. The purpose of this paper is to analyze the dependence of the gas pressure and the gap at surface flashover voltage in dry air. The dependence is analyzed based on the medium effect. The medium effect by the gas pressure and the gap can be explained by surface roughness of a solid dielectric and an electrode as well as an electric field which decreases due to the correlation between the collision ionization coefficient and the gap, respectively. In addition, an insulation technique which can fabricate a compact eco-friendly gas insulated switchgear is proposed by the results of this paper.

An Improvement of the Gas Discharge Structure of the AMD Gate PDP (AND Gate PDP의 기체방전구조 개선)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.42-47
    • /
    • 2004
  • This research has improved the problem of discharge AND gate PDP proposed before. The polarity of the DC discharge which composes AND gate is reversely designed and the cross talk problem to the adjacent scanning electrode has been improved. The AND gate proposed before operated by using non-linearity of the discharge by the space charge. In this research, new discharge NOT logic in which it was used that an applied voltage changed with the discharge circuit was added to AND gate. AND gate came to operate more stably. A selective address was able to be discharged with four horizontal scanning electrodes from the experiment result. The operation margin of the AND gate discharge obtained 34V and of the address discharge obtained 70V.

Detection of Partial Discharge Acoustic Signal Using the Optical Fiber Interferometric Sensor (광섬유 간섭계 센서를 이용한 부분방전 음압 측정)

  • 이종길;박윤석;이준호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.614-623
    • /
    • 2002
  • In this paper, it was manufactured an interferometric optical fiber sensor and measured partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Acrylic and aluminium mandrels wound with fiber-optic were chosen as optical fiber sensor, Sagnac and Mach-Zehnder interferometers were chosen to detect discharge acoustic signals. The two fiber optic interferometers were identified by using the PZT. Discharge experimentation set in the discharge imitation cell in oil tank and the discharge phenomena was generated. Based on the experimental result, to detect the discharge acoustic signal, Sagnac interferometer can detect stably the acoustic signal than the Mach-Zehnder interferometer. It is shown that Sagnac optical fiber sensor can detect the discharge acoustic signals effectively.

A Study on the Characteristics on a Discharge Cell by the Electrode Gap Using 2-D Simulation (2차원 시뮬레이션을 이용한 전극 간격에 따른 방전셀 내부의 특성 연구)

  • Lee, Don-Kyu
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.524-528
    • /
    • 2019
  • Although different types of discharge cells exist, in common it is the primary goal for all discharge cells to have lower drive voltages and higher efficiency characteristics. To improve these factors, many studies are conducted that prolong the discharge path inside the discharge cell or change the composition of the working gas. In this paper, the two-dimensional fluid simulation was used to calculate the discharge voltage (firing voltage and sustain voltage) and the change in luminance and luminous efficacy according to the change in gap distance between discharge electrodes. In addition, we looked at changes in various charged particles, exciting particles and VUV particles, and studied the causes of the resulting values.

Partial Discharge Characteristics on Protrusion Defects in SF6-N2 Mixture Gases (SF6-N2 혼합가스 중 돌출 결함의 부분방전 특성)

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Park, Kyoung-Soo;Kil, and Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2016
  • Studies on a $SF_6$-mixture and -alternative gas has been in progress to reduce the use of $SF_6$ gas as an insulation material of GIS (gas insulated switchgears). In this paper, we dealt with PD (partial discharge) characteristics in pure $SF_6$ and $N_2$, and their mixtures on aspects of insulation design and risk assessment for GIS. A POC (protrusion on conductor) and a POE (protrusion on enclosure) as the major defects were fabricated to simulate PD. We analyzed the DIV (discharge inception voltage), DEV (discharge extinction voltage), pulse magnitude, counts and phase distribution of PD pulse in $SF_6-N_2$ mixtures ($SF_6$ 100%, $SF_6$ 80%-$N_2$ 20%, $SF_6$ 50%-$N_2$ 50%, $SF_6$ 20%-$N_2$ 80%, and $N_2$ 100%) according to the IEC60270. The DIV, DEV as well as magnitude of PD pulse decreased on the POC as increase of $N_2$ ratio. For the POE, the DIV and DEV in $N_2$ ratio below 50% were the same voltages as those in $SF_6$ 100%. In this experiment, $SF_6$ 80%-$N_2$ 20% mixture could be considered with the equivalent insulation performance to a GIS.

Effect of an Additives on Simultaneous Removal of NOx, $So_2$by Corona Discharge (코로나 방전에 의한 NOx, $So_2$동시제거에서 첨가제의 영향)

  • 박재윤;고용술;이재동;손성도;박상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.5
    • /
    • pp.451-457
    • /
    • 2000
  • Experimental investigations on the effect of two kinds of additives ; aqueous NaOH solution and ammonia(NH$_3$) for removal of NOx and SO$_2$ simultaneously by corona discharge were carried out. The simulated combustion flue gas was[NO(0.02[%])-SO$_2$(0.08[%])-$CO_2$-Air-$N_2$] Volume percentage of aqueous NaOH solution used was 20[%] and $N_2$flow rate was 2.5[$\ell$/min] for bubbling aqueous NaOH solution Ammonia gas(14.81[%]) balanced by argon was diluted by air. NH$_3$ molecular ratios(MR) based on [NH$_3$] and [NO+SO$_2$] were 1, 1.5 and 2.5 The vapour of aqueous NaOH solution and NH$_3$was introduced to the main simulated combustion flue gas duct through injection systems which were located at downstream of corona discharge reactor. NOx(NO+NO$_2$) removal rate by injecting the vapour of aqueous NaOH solution was much better than that by injecting NH$_3$however SO$_2$removal rate by injecting NH$_3$was much better than that by injecting the vapour of aqueous NaOH SO$_2$removal rate slightly increased with increasing applied voltage. When the vapour of aqueous NaOH solution and NH$_3$were simultaneously injection NOx and SO$_2$ removal rate were significantly increased.

  • PDF

The Surface Energy Change of TAC Film Treated by an Atmospheric Pressure Plasma (대기압 플라즈마 처리에 의한 TAC 필름의 표면에너지 변화)

  • Lee, Chang-Ho;Jung, Do-Young;Park, Young-Jik;Song, Hyun-Jig;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.184-190
    • /
    • 2009
  • Tri-acetyl-cellulose(TAC) film surface was modified by atmospheric-pressure plasma technique to obtain the hydrophilic functional groups and improve the contact angle. TAC film was modified with N2 plasma ionized in dielectric barrier discharge(DBD) reactor under atmospheric pressure. We measured the change of the contact angle and the surface energy with respect to the plasma treatment conditions such as plasma treatment power, discharge gap and N2 gas flow rate. As the plasma treatment speed of 100[mm/sec], the plasma treatment power of 1.5[kW], discharge gap 2[mm] and the $N_2$ gas flow rate 140[LPM], the best contact angle and the highest surface energy were obtained. The degree of hydrophilization depended strongly on the plasma-treating time and discharge power.

Performance Characteristics of a Pin-to-Cylinder Superposed Discharge Type Ozonizer (SDO)

  • Md. Fayzur Rahman;Lee, Kwang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.113-119
    • /
    • 2001
  • This paper presents a model for a pin-to-cylinder discharge type ozonizer, which utilizes the superposition of surface discharge and corona discharge operation. By changing the gas flow rate, the discharge power and the number of SDO units, the characteristics of ozone concentration ( $O_{3con}$), ozone generation ( $O_{3g}$) and ozone yield ( $O_{3Y}$) were investigated. Using one SDO unit the maximum values of $O_{3con}$, $O_{3g}$ and $O_{3Y}$ were found as 8100[ppm], 1623[mg/h] and 213[g/kWh] respectively. With two SDO units the corresponding values were found as 12800[ppm], 2893[mg/h] and 248[g/kWh] respectively. Hence using two SDO units the efficiency was improved by 16[%].y 16[%].

  • PDF