• 제목/요약/키워드: Gas Discharge

검색결과 1,507건 처리시간 0.03초

Flowing Gas의 방전특성에 관한 연구 (A Study on Sparkover Discharge Characteristics of Flowing Gas)

  • 오재열;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.296-299
    • /
    • 1991
  • This paper reports the characteristics of sparkover discharge in flowing gas ranging from 0[m/s] to 30[m/s] under the needle-rod gap. The important results obtained from this paper are as followers. 1. The maximum sparkover voltage of flowing gas are about 3.1[kv](d=1[cm], 5.4[kv](d=2[cm]), 8.1[kv](d=3[cm]) higher than those of static gas 2. The empirical equation obtained from this experiment is [%]$\frac{Vs}{Re}=A\;log_{10}\;Re+B$ where A=$-7.79{\times}10$ B=$5.60{\times}10^2$ 3. The duration time of sparkover decreases with increasing the Reynolds number. 4. The discharge pattern can be controlled by adjustment of the Reynolds number

  • PDF

Discharge characteristics of a Flat Fluorescent Lamp(FFL) contanining Penning gases

  • Lee, Sang-Mok;Cho, Yong;Jung, Sang-Kooun;Jeong, Byoung-Hyun;Jeong, Yun-Cheol;Kwak, Min-Gi;Sohn, Sang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.675-678
    • /
    • 2006
  • We developed a Flat Fluorescent Lamp(FFL) with a high luminance by using the same discharge mode as PDP. Our FFL has the simple and unique structure where the glass substrates are used as dielectric layers. The panel has a striped line shape of 7 inch diagonal size. The Xe-Ne-He mixture gas was used to generate the plasma, and the gas discharge characteristics under both total gas pressure and partial gas pressure were investigated. The panel showed a maximum high luminance $7,270cd/m^2$ under bias of 20KHz pulse of 3KV.

  • PDF

유한요소법을 이용한 침대 평판 전극에서의 $SF_6$ 가스 방전 특성 해석 (A study on the discharge characteristics of $SF_6$ gas by Finite Element Methods in needle to plane electrode)

  • 현정수;박필용;최승길;심재학;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.700-703
    • /
    • 1999
  • Thls paper describes the process of corona discharge in $SF_6$ gas. The discharge characteristm such as electric field distribution, electron density, ion density and current denslty distribution are considered as time go by, The result show that difference between electronegative gas and nonelectronegative gas.

  • PDF

LPG용 압력방출밸브 방출관 설치기준 개선방안 (A Study on Standards for Pressure Relief Valve Vent Pipes from LPG Storage Tanks)

  • 이진한;엄석화;김래현
    • 한국가스학회지
    • /
    • 제16권4호
    • /
    • pp.59-64
    • /
    • 2012
  • LPG 저장설비에 부착된 압력방출밸브 방출관으로부터 분출된 가스의 확산에 대해 검토하였다. 통상 방출관은 안전한 장소인 수직 상방향으로 분출되도록 설치되어야 하며, 방출된 가스가 착화되더라도 저장탱크, 장치, 배관에 화염이 닿지 않도록 설치되어야 한다[1][2]. 그러나 우리나라에서는 방출구를 통한 분출방향에 대한 기준이 없이 다양한 방출구 형태가 존재한다. 따라서, 본 연구에서는 4가지 방출방향 즉 수직상방, 수직하방, 수평 2, 수직 4방향에 대해서 고려하였다. 방출구로부터 분출된 가스의 확산 시뮬레이션은 상용소프트웨어인 FLACS를 사용하였다. 이를 통해 수직하방, 수평 2, 수직 4방향으로 분출하도록 방출구를 설치하는 것은 지면에서의 착화를 방지하는 데 불리한 것으로 나타났다. 따라서 안전밸브로부터 분출된 가스를 방출구를 통해 안전하게 분출하기 위해서는 수직상방으로 분출되는 것이 최선임을 알 수 있었다.

중실원추형 및 중공원추형 2유체 미립화기의 화재 소화 성능 검토: 공급 기체와 미분무 영향 (Examination on Fire Extinguishing Performance of Full Cone and Hollow Cone Twin-fluid Atomizers: Effects of Supply Gas and Water Mist)

  • 김동환;이치영
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.28-36
    • /
    • 2019
  • 본 연구에서는 분사 형태(Spray pattern)가 중실원추형(Full cone) 및 중공원추형(Hollow cone)인 2유체 미립화기를 이용하여 공급 기체 및 미분무가 헵탄 풀화재(Heptane pool fire) 소화 성능에 미치는 영향을 검토하였다. 2유체 미립화기의 공급 기체로 30 lpm (Liter per minute; L/min)의 공기 또는 질소를 이용하였으며, 물을 공급하지 않은 경우(즉, 공기 또는 질소만 분사한 경우)와 물 0.085 lpm을 공급한 경우(즉, 미분무와 공급 기체를 함께 분사한 경우)에 대해 실험을 수행하였다. 실험 결과, 공급 기체만 분사한 경우보다 미분무와 공급 기체를 함께 분사한 경우에, 그리고 중공원추형인 경우보다 중실원추형인 경우에 빠르게 화재 소화 가능함을 확인하였다. 또한, 중실원추형의 경우, 미분무와 공급 기체 함께 분사 시 화재 소화 성능에 미분무의 영향은 지배적이었으나 공급 기체의 영향은 미비한 것으로 관찰되었다. 반면, 중공원추형의 경우, 중실원추형과 달리 미분무와 공급 기체 함께 분사 시 공급 기체로 질소를 공급한 경우가 공기를 공급한 경우에 비해 평균 화재 소화 시간이 확연하게 짧아지는 것으로 측정되었고, 이를 통해 미분무 뿐 아니라 공급 기체도 화재 소화 성능에 지대한 영향을 미칠 수 있음을 확인하였다.

장애물이 있는 챔버 내부의 정전기 방전 에너지에 의한 가스 폭발시 초기화염과 화염전파 특성에 대한 PIV 계측 (PIV Measurements on the Flame Initiation and Propagation under Gas Explosions by Electrostatic Discharge Energies in a Confined Chamber with an Obstacle)

  • 박달재;이석환;성재용;이영순
    • 대한기계학회논문집B
    • /
    • 제33권9호
    • /
    • pp.682-687
    • /
    • 2009
  • In order to investigate the effects of three different electrostatic discharge energies on gas explosions, a high-speed PIV system has been applied. The present study paid attention to the flame initiation by the gas explosions and its propagation at the existence of an obstacle within a chamber. Three different ignition energies such as 0.56 mJ, 52.87 mJ and 112.5 mJ were used. It is found that the ignition kernel is bent by the electrostatic discharge during the flame initiation. Tangential velocities of unburnt mixture ahead of initially propagating flame fronts are increased with increasing ignition energy, which makes the flame propagation faster before it reaches the obstacle. Although the flame speed was found to be less sensitive to the ignition energies, the flame developments were different. The effects of the energies on explosion pressures were also discussed.

LCD 배면광원용 무수은 형광램프의 전기.광학적 특성 (Electro-Optical Characterization of Hg-Free Fluorescent Lamps for LCD Backlight)

  • 이순석;임성규
    • 한국콘텐츠학회논문지
    • /
    • 제6권12호
    • /
    • pp.163-168
    • /
    • 2006
  • LCD의 배면광원으로 활용될 무수은 형광램프를 제작한 다음, 전기 광학적 특성을 평가하였다. PDP 형광체, nitro-cellulose 및 n-butyl acetate를 혼합하여 유리관 내부에 얼룩 없이 균일하게 코팅하였다. 또 $550^{\circ}C$에서 20 분 동안 소성하였고, 가스혼합장치를 이용하여 $10^{-6}$ torr까지 배기시킨 다음 방전가스를 주입하여 형광램프를 완성시켰다. 형광체 두께 및 유리관 직경 등을 변화시켜 제작, 평가한 결과 이들 변수들에 대하여 최적의 값을 찾아 낼 수 있었다. 또한 Ne+Xe 방전가스를 주입하여 제작된 형광램프에 75 kHz의 정현파 전압을 공급시킨 결과 휘도 $6,270cd/m^2$, 발광효율 13 lm/W를 얻었다.

  • PDF

친환경 절연설계를 위한 N2/O2 혼합가스 중 고체유전체 종류에 따른 연면방전특성 (Surface Discharge Characteristics of Solid Dielectrics in N2/O2 Mixture Gas for Eco-Friendly Insulation Design)

  • 임동영;박혜리;최은혁;최상태;이광식
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.9-15
    • /
    • 2012
  • In this paper, we deal with a surface discharge that caused an aggravation of the dielectric strength in the $N_2/O_2$ mixture gas, When composit dielectrics were formed from the use of a solid dielectric. It was found from this study that the surface discharge voltage was deeply involved in the mixture ratio of $O_2$, the electrical property of the solid dielectric, kind of the solid dielectric, an electric field at the triple junction and a medium effect. These results expect basic data that will be used to transmission and distribution power system equipment using the $N_2/O_2$ mixture gas.

주사바늘 전극형 오존발생기 특성 연구 (Observation and Characteristics of Ozonizer using Injection Needle Electrode)

  • 박현미;권영학;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.77-82
    • /
    • 2015
  • Ozone is a powerful disinfectant and oxidizing agent, and it is used in a wide range of applications, such as waste water treatment, food processing, etc.. There is also a great potential of using ozone in new emerging medical applications, such as ozone dentistry and ozone oxygen therapy. For these purposes, simple, small, compact and efficient sources of ozone are needed. In this study, in order to increase the current-voltage range of the discharge and to avoid the overheating of the gas in the ozonizer we suggested ozonizer of injection needle and plate electrode type(INP Type) with the gas through the needle. A ozonizer of INP type have been investigated by focusing on ozone concentration and yield according to flow rates and Gap of two electrodes. The results of studies of ozone production for DC corona discharge in oxygen at atmospheric pressure about the ozonizer of INP type. The ozone concentration and the generation yield increased as the gap of two electrodes and gas flow were decreased. Also, when the gap of two electrodes and gas flow with no change, the ozone concentration and generation yield each have variation of direct proportion and inverse proportion with discharge voltage.

75톤급 액체로켓엔진 축소형 가스발생기 연소시험 결과 (Hot-firing Test Results of Subscale Gas Generator for 75 ton-class Liquid Rocket Engine)

  • 김문기;안규복;임병직;김종규;서성현;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.726-728
    • /
    • 2010
  • 75톤급 가스발생기 개발을 위한 분사기의 설계 변수에 따른 유량계수의 영향을 파악하기 위하여 축소형 가스발생기를 설계, 제작하였으며, 연소시험을 성공적으로 수행하였다. 연소시험 결과 연료 및 산화제 분사기의 유량계수는 혼합비와 연소압에 상관없이 거의 일정한 것으로 나타났으며, 산화제 분사기의 노즐 지름을 줄인 경우 분사기 차압이 줄어들어 유량계수가 증가하는 것을 확인하였다.

  • PDF