• Title/Summary/Keyword: Gas Cooling

Search Result 1,091, Processing Time 0.03 seconds

Effect of Spray Angle of Water Mist Nozzle on Temperature Field of Compartment Fire (물분무노즐의 분사각이 화재실 내부의 온도장에 미치는 영향)

  • 김성찬;유홍선;박현태;방기영
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.28-33
    • /
    • 2003
  • The present study investigates the effect of injection angle of water mist on fire suppression characteristics by numerical simulation. In order to validate the temperature field by numerical simulation, the predicted results are compared with experimental data. It shows that the temperature difference between measurements and predictions are within $10^{\circ}C$. Numerical simulations of fire suppression are performed for 4 different injection angle($60^{\circ}$, $90^{\circ}$, $^120{\circ}$, and $180^{\circ}$). The global mean temperature over the fire compartment decrease with increasing of spray angle. The result shows that the heat transfer between droplets and gas phase are enhanced with the increasing of spray angle. Near the fire source, temperature field by the wide spray angle is slightly higher than that of narrow injection angle because of direct cooling of fire source.

Time Estimation of Forming and Extinguishing Arc in the dc Contactor at Opening Contacts (접점 개방시 직류 접촉기의 아크 형성과 소호 시간 예측법)

  • Cho Hyun-Kil;Lee Eun-Woong;Kim Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.788-790
    • /
    • 2004
  • This paper describes the phenomenon of the molten metal bridge theory of the arc discharge at opening contacts. And we analyze the magnetic force and drag force acting on the arc column in the DC magnetic contactor Arc cooling time by the force convection is calculated in the thermal dynamic equation using mean temperature method. Since arc gas lost conduction characteristics below a such temperature, it verify that the process of forming and extinguishing arc is able to analyze in terms of temperature characteristic by simulation and experiments of the 3 types arc extinction unit. It propose the practical simulation method to improve the electrical endurance of dc contactor.

  • PDF

A Study on the Improvement of Combustion Stability for SI Engine at Idle Operation (SI 기관의 공회전시 연소 안정성 향상에 관한 연구)

  • Lee, J.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.259-266
    • /
    • 1998
  • In the SI engine, the improvement of combustion stability is important not only for the fuel consumption rate but also for the emission control at idling of engine. Thus the engine speed fluctuation at idle operation mainly comes from cyclic variation of combustion in the SI engine. In this syudy, the improvement of combustion stability for the SI engine at idle condition by the cooling water temperature, duty ratio of ISC, spark ignition timing as well as the reducement of the harmful exhaust gas emission was discussed.

  • PDF

The Dielectric Characteristics of Low Density Polyethylene Film due to Thermal Treatment Effect (열처리효과에 따른 저밀도 폴리에틸렌 박막의 유전특성)

  • 김왕곤;가출현;이용우;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.1
    • /
    • pp.67-74
    • /
    • 1996
  • In order to investigate the effect and reliability coming up to properties of the matter due to the change of solid structure in dielectrics, the effect of dielectric characteristics for thermal treated LDPE film was made researches. Specimens of LDPE with thickness 100 [$\mu\textrm{m}$] were investigated into the change of solid structure by ageing. Thermal treated specimen were made, that were after applying heat at 100 [$^{\circ}C$] for 1 [hour] \circled1 air-cooled specimen slowly, \circled2 water-cooled specimen under the ,com temperature, \circled3 liquid nitrogen gas-cooled specimen rapidly. With specimen of thermal treated three types turn out and original, it was for dielectric characteristics to be experimented in the temperature range of 20~120 [$^{\circ}C$], frequency range of 30~1.5${\times}10^5/$[Hz], appling voltage from 300 to 1500[㎷]. Consequently, the degree of crystallinity was changed with 49~57 [%] according to the thermal treatment. In case of frequency, 100 [Hz], on the thermal dependance in dielectric characteristics, tan decreases due to cooling method.

  • PDF

The Design of Flat Linear Induction Pump for Transferring Reactor Coolant (원자로 냉각재 이송을 위한 평편형 리니어 유도펌프의 설계)

  • Jang, S.M.;Wu, J.S.;Kim, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.10-12
    • /
    • 1998
  • Pumping liquid metal in nuclear power plant application by conventional centrifugal pumps pose difficulties such as bearing wear out at high temperatures and leak proof sealing of the liquid metal. MHD machine is obtained by replacing solid conducting secondary of conventional motors with ionized gas or liquid metal. It is used for reactor cooling pump because of construction simplicity, perfect sealing and easy operation/maintenance MHD pump is complicated because it includes electromagnetic and hydrodynamic phenomena. The principle of MHD Pumps is described in this paper. We design small laboratory size Flat Linear Induction Pump(FLIP) for transferring sodium.

  • PDF

Performance Analysis of R-1270(Propylene) Refrigeration System Using Internal Heat Exchanger (내부 열교환기를 이용한 R-1270용 냉동시스템의 성능 분석)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.36-42
    • /
    • 2014
  • This paper considers the influence of internal heat exchangers on the efficiency of a refrigerating system using R-1270. These internal heat exchangers(liquid-gas or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed. The main results were summarized as follows : the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, and effectiveness have the influences on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. With a thorough grasp of it is possible to design the R-1270 compression refrigeration cycle using internal heat exchanger.

Performance of a Reciprocating Compressor Equipped with Auxiliary Port (보조 흡입구가 장착된 왕복동 압축기의 성능 분석)

  • Lee, Yong-Ho;Kim, Hyun-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.637-644
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

A study on the characteristics of a frozen start up for a variable conductance heat pipe (가변전열 히트파이프의 저온 시동특성에 관한 연구)

  • Hong, Sung-Eun;Kang, Hwan-Kook;Cho, Kwang-Cheal
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.339-345
    • /
    • 2006
  • This these was conducted to investigate tile characteristics of a frozen start up for a VCHP which has water as a working fluid and Nitrogen as a non-condensible gas. The tested heat pipe was made of a copper tube with the outer diameter of 12.7 mm, the length of 340 mm, and the sintered metal wick had the thickness of 0.7 mm. This experiment was conflicted under the thermal load, inclined angle and cooling conditions.

  • PDF

Study on Ventilation Performance of Multi-room in Apartment - Airflow and Ventilation Effectiveness in Multi-room - (공동주택의 환기방식별 다수실 환기 성능에 관한 연구 - 다수실의 환기경로 및 환기효율 -)

  • Kwon, Kyung-Woo;Cho, Si-Jin;Choi, Eui-Sung;Park, Jun-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.399-404
    • /
    • 2006
  • Heating and cooling load of ventilation is a very important part of building energy saving. Improving ventilation effectiveness can save building energy consume and supply fresh air to indoor efficiently. So this study measured mulity-zone aiflow and ventilation effectiveness according to ventilation types. Result of measurement show that ventilation effectiveness is depends on ventilation system design rather than ventilation types.

  • PDF

Vibronic Assignments of the $S_1 \rightarrow S_0$ Emission Spectrum of the Jet Cooled p-Fluorotoluene

  • 하영미;최익순;이상국
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.2
    • /
    • pp.202-206
    • /
    • 1998
  • The p-fluorotoluene was vibronically excited in a jet with a buffer gas He in a corona excited supersonic expansion. The vibronic emission spectrum of the jet cooled p-fluorotoluene in the transition of S1 → S0 has been recorded with a Fourier transform spectrometer in the uv region. The spectrum observed was analyzed to obtain accurate vibrational frequencies in the ground electronic state by comparing with those reported previously. The origin of the low frequency sequence bands observed in this work was discussed. Also, the absence of significant intensity of hot band resulting from the excited vibrational states in the spectrum suggests extensive vibrational cooling in the source.