• 제목/요약/키워드: Gas Condensate

검색결과 37건 처리시간 0.022초

Monitoring of the Content of Imidazoline-Containing Corrosion Inhibitor

  • Zadorozhny, P.A.;Sukhoverkhov, S.V.;Markin, A.N.;Savin, K.I.;Prokuda, N.A.
    • Corrosion Science and Technology
    • /
    • 제16권4호
    • /
    • pp.161-166
    • /
    • 2017
  • The qualitative composition of active components of the corrosion inhibitor CGW-85567 was studied. It was found that С18:2 and С18:1 imidazolines and the corresponding imidazolin-amides are the major components. The HPLC/MS technique was developed for their determination in the water solutions of monoethylene glycol (MEG). Industrial application of the inhibitor showed that MEG solution retained high concentration of the inhibitor for a long time after ceasing its addition into pipelines. Low values of the partition coefficients (0.010-0.014) of imidazolines in the system "water solution of MEG (concentration of MEG 62-85% v/v) - gas condensate" have allowed to pass on from the technology of continuous pumping of the inhibitor into protected pipelines to the periodic dosing technology. Taking into account a long time of circulation in the system and high temperatures during MEG regeneration process possible degradation products of the inhibitor were studied. N, N-dimethyl-dodecanamine-1, and N, N-dimethyl-tetradecanamine-1 were identified as major degradation products of the corrosion inhibitor CGW-85567.

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.104-104
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.

  • PDF

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.486-497
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate, A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side has a shape of annulus around vertical tube and the lost heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 11 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348∼3.282kg/hr, of inlet air mass fraction 11.8∼55.0%. The investigation of the flooding is preceded to find the upper limit of the reflux condensation. Onset of flooding is lower than that of Wallis' correlation. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the increase of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed by 165 data of the local heat transfer. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17.7% between the results by the experiment and by the correlation.

  • PDF

화산가스의 채취 및 분석에 대한 기술보고 (A Technical Note on Monitoring Methods for Volcanic Gases)

  • 이승열;이상철;양경희;정훈영
    • 암석학회지
    • /
    • 제21권4호
    • /
    • pp.415-429
    • /
    • 2012
  • 화산가스의 측정법은 크게 원격 측정법과 직접 채취법이 있다. 원격 측정법에서 COSPEC는 $SO_2$를, Li-COR는 $CO_2$를, FT-IR는 다양한 화산가스를 측정한다. 하지만 주변 수계의 영향으로 백두산의 화산가스 농도가 낮아 원격 측정법에 의한 화산가스의 분석은 불가능하다. 대신 직접 채취법은 화산체에서 분출하는 화산가스를 직접 채취해 분석하는 방법으로 화산가스의 농도가 낮은 백두산에 적용할 수 있다. 직접 채취법은 포집방법에 따라서 진공병법과 관류병법이 있으며, 포집용액에 따라 Giggenbach method, $NH_4OH$ method, acid condensate method로 나뉜다. 직접 채취법에 의해 얻은 시료는 전처리 과정을 거친 후 포집용액과 화산가스의 종류에 따라서 GC, IC, HPLC, 적정법, TOC-IC, ICP-MS 등을 이용해 분석한다. 최근 들어 백두산이 가까운 장래에 다시 분출할 것이라는 징후가 속속 보고되고 있다. 하지만, 현재 우리나라는 화산가스의 채취 및 분석법이 확립되지 않은 실정이다. 따라서 본 연구에서는 지금까지 보고된 다양한 화산가스의 측정법을 검토하고, 이들 중 백두산 화산가스의 측정에 활용 가능한 기법을 상술했다.

생활폐기물 매립장 침출수의 삼중수소 분포 (Tritium Distribution in Leachates from Domestic Solid Waste Landfills)

  • 박순달;김정석;조기수;김종구;김원호
    • 분석과학
    • /
    • 제17권3호
    • /
    • pp.251-262
    • /
    • 2004
  • 생활폐기물을 매립, 처리하는 위생매립장에서 발생된 침출수의 삼중수소 분포 특성을 조사하기 위해 침출원수, 처리수 및 메탄가스응축수의 삼중수소 농도를 측정하였다. 또한 침출수 및 처리수의 콜로이드 크기에 따른 삼중수소의 용존특성을 조사하였다. 침출수의 주요 무기물 오염성분은 Na, K, Ca, Mg, 암모니아성 질소 및 염소이온이었다. 연구대상 매립장중 2개 매립장을 제외한 나머지 매립장의 침출수에서 환경준위보다 수십 내지 수백 배 이상 높은 농도의 삼중수소가 검출되었으며, 조사기간중 침출수의 평균 삼중수소 농도분포는 17 ~ 1196 TU였다. 메탄가스응축수 및 침출수 처리공정을 거친 처리수에서도 침출수와 비슷한 수준의 삼중수소가 검출되었다. 이와 같은 삼중수소의 농도는 삼중수소의 음용수 기준에 비해 약 100배 이상 낮은 수준임을 확인할 수 있었다. 침출수중 삼중수소는 대부분 $0.45{\mu}m$ 이하의 용해성 콜로이드에 분포되어 있었나, 일부는 $0.45{\mu}m$ 이상의 콜로이드에 분포되어 있는 것으로 추정되었다. 침출수의 삼중수소와 총유기성탄소가 상대적으로 높은 상관성을 나타내었다. 그러나 침출수의 삼중수소 농도는 매립장의 규모, 수문학적 특성 및 매립연령 등과 특별한 상관성이 없는 것으로 나타났다.

테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes)

  • 이장호;김형대;김정배;김무환
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

외부 개질형 평판형 고체 산화물 연료전지 시스템 구성법에 따른 효율특성 (A Case Study of Different Configurations for the Performance Analysis of Solid Oxide Fuel Cells with External Reformers)

  • 이강훈;우현탁;이상민;이영덕;강상규;안국영;유상석
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.343-350
    • /
    • 2012
  • 본 연구에서는 외부 개질기에 열원을 공급하기 위한 시스템 내에 가용한 열에너지의 활용 및 확보에 대한 해석을 위해서 외부 개질기를 연계한 평판형 SOFC 시스템의 해석 모델을 구축하고자 한다. 이러한 해석을 위한 모델 구축을 위해 Matlab simulink$^{(R)}$ 기반의 ThermoLib module을 사용하였으며, 구축된 해석 모델을 통하여 시스템의 성능 향상을 위한 구성 기법에 대해서 연구를 하였다. 시스템 구성 방법은 기존 시스템의 layout을 바꾸기 위해 공기극 출구가스 재순환 및 외부개질기와 촉매연소기를 통합한 개질반응시스템 적용, 개질기에 공급되는 혼합연료의 예열, 연료극 출구가스의 응축을 통한 연료 농도 향상 등을 고려하였다. 시뮬레이션의 해석 결과에서는 SOFC 시스템에 있어서 일반 연소기를 적용한 기준 시스템에 비하여 촉매 연소기를 사용한 시스템의 전기 효율이 12.13% 향상되었으며, 연료극 출구 가스를 응축시켜 버너로 연소시킨 시스템에서는 열효율이 76.12%로 가장 높았다.