• Title/Summary/Keyword: Gas Condensate

Search Result 37, Processing Time 0.023 seconds

Monitoring of the Content of Imidazoline-Containing Corrosion Inhibitor

  • Zadorozhny, P.A.;Sukhoverkhov, S.V.;Markin, A.N.;Savin, K.I.;Prokuda, N.A.
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.161-166
    • /
    • 2017
  • The qualitative composition of active components of the corrosion inhibitor CGW-85567 was studied. It was found that С18:2 and С18:1 imidazolines and the corresponding imidazolin-amides are the major components. The HPLC/MS technique was developed for their determination in the water solutions of monoethylene glycol (MEG). Industrial application of the inhibitor showed that MEG solution retained high concentration of the inhibitor for a long time after ceasing its addition into pipelines. Low values of the partition coefficients (0.010-0.014) of imidazolines in the system "water solution of MEG (concentration of MEG 62-85% v/v) - gas condensate" have allowed to pass on from the technology of continuous pumping of the inhibitor into protected pipelines to the periodic dosing technology. Taking into account a long time of circulation in the system and high temperatures during MEG regeneration process possible degradation products of the inhibitor were studied. N, N-dimethyl-dodecanamine-1, and N, N-dimethyl-tetradecanamine-1 were identified as major degradation products of the corrosion inhibitor CGW-85567.

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.104-104
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.

  • PDF

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.486-497
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate, A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side has a shape of annulus around vertical tube and the lost heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 11 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348∼3.282kg/hr, of inlet air mass fraction 11.8∼55.0%. The investigation of the flooding is preceded to find the upper limit of the reflux condensation. Onset of flooding is lower than that of Wallis' correlation. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the increase of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed by 165 data of the local heat transfer. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17.7% between the results by the experiment and by the correlation.

  • PDF

A Technical Note on Monitoring Methods for Volcanic Gases (화산가스의 채취 및 분석에 대한 기술보고)

  • Lee, Seungyeol;Lee, Sangchul;Yang, Kyounghee;Jeong, Hoon Young
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.415-429
    • /
    • 2012
  • The monitoring methods for volcanic gases are divided into remote sensing and direct gas sampling approaches. In the remote sensing approach, COSPEC and Li-COR are used to measure $SO_2$ and $CO_2$, respectively, with FT-IR for detection of a range of volcanic gases. However, the remote sensing approach is not applicable to Mt. Baegdu, where the atmospheric contents of volcanic gases are very low as a result of the strong interaction of volcanic gases with the nearby surface water and groundwater. On the other hand, the direct gas sampling approach involves the collection of volcanic gases from volcanic vents or fumaroles and the subsequent laboratory analysis, thus making it possible to measure even very low levels of volcanic gases. The direct sampling approach can be subdivided into the evacuated bottle method and the flow-through bottle method. In applying both methods, sampling bottles typically contain reaction media to trap specific volcanic gases. For example, NaOH solution(Giggenbach bottle), $NH_4OH$ solution, and acid condensates have been experimented for volcanic gas sampling. Once taken from vents and fumaroles, the samples of volcanic gases are pretreated and subsequently analyzed for volcanic gases using GC, IC, HPLC, titrimetry, TOC-IC, or ICP-MS. Recently, there has been the increasing number of evidences on the potential volcanic activity of Mt. Baegdu. However, little technical development has been made for the sampling and analysis of volcanic gases in Korea. In the present work, we reviewed various volcanic gas monitoring methods, and provided the detailed information on the monitoring methods applied to Mt. Baegdu.

Tritium Distribution in Leachates from Domestic Solid Waste Landfills (생활폐기물 매립장 침출수의 삼중수소 분포)

  • Park, Soon Dal;Kim, Jung Suk;Joe, Kih Soo;Kim, Jong Gu;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.251-262
    • /
    • 2004
  • It is for the purpose of investigating the tritium distribution in the leachates, the raw and treated leachates and the condensates of the methane gas, which have occurred from domestic solid waste landfills. Also it aims to measure the tritium distribution level on the colloid size of the leachates, the raw and treated leachates. It was found that the major inorganic contaminants of the leachates were Na, K, Ca, Mg, $NH{_4}^+$-N and $Cl^-$. The mean tritium level of the raw leachates of the investigated 13 landfill sites for 6 months was 17 ~ 1196 TU. It corresponded to a several scores or hundreds of magnitude higher value than that of the normal environmental sample level except for two landfill sites. Also such a high concentration of the tritium was found in the treated leachates and methane gas condensates as well. Nevertheless it is important to emphasize that the tritium level which was found in this research is about 100 times lower than the tritium limit for the drinking water quality. And most of the tritium existed in the dissolved colloid of the leachate of which the colloid size is below $0.45{\mu}m$. Also, according to the tritium analysis results of the leachates after filtration with $0.45{\mu}m$ membrane filter for some landfills, it is likely that some tritium of the leachate would be distributed in a colloid size over $0.45{\mu}m$. In general the relationship between the tritium and other contaminants in the raw leachate was low, but it was relatively high between the tritium and TOC. However, the tritium content in the leachate had no meaningful relationship with the scale, hydrological characteristics and age of the landfill.

Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes (테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구)

  • Lee, Jang-Ho;Kim, Hyeong-Dae;Kim, Jung-Bae;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

A Case Study of Different Configurations for the Performance Analysis of Solid Oxide Fuel Cells with External Reformers (외부 개질형 평판형 고체 산화물 연료전지 시스템 구성법에 따른 효율특성)

  • Lee, Kang-Hun;Woo, Hyun-Tak;Lee, Sang-Min;Lee, Young-Duk;Kang, Sang-Gyu;Ahn, Kook-Young;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.343-350
    • /
    • 2012
  • A planar solid oxide fuel cell (PSOFC) is studied in its application in a high-temperature stationary power plant. Even though PSOFCs with external reformers are designed for application from the distributed power source to the central power plant, such PSOFCs may sacrifice more system efficiency than internally reformed SOFCs. In this study, modeling of the PSOFC with an external reformer was developed to analyze the feasibility of thermal energy utilization for the external reformer. The PSOFC system model includes the stack, reformer, burner, heat exchanger, blower, pump, PID controller, 3-way valve, reactor, mixer, and steam separator. The model was developed under the Matlab/Simulink environment with Thermolib$^{(R)}$ modules. The model was used to study the system performance according to its configuration. Three configurations of the SOFC system were selected for the comparison of the system performance. The system configuration considered the cathode recirculation, thermal sources for the external reformer, heat-up of operating gases, and condensate anode off-gas for the enhancement of the fuel concentration. The simulation results show that the magnitude of the electric efficiency of the PSOFC system for Case 2 is 12.13% higher than that for Case 1 (reference case), and the thermal efficiency of the PSOFC system for Case 3 is 76.12%, which is the highest of all the cases investigated.