• Title/Summary/Keyword: Gas Combustion

Search Result 3,050, Processing Time 0.034 seconds

Deep learning neural networks to decide whether to operate the 174K Liquefied Natural Gas Carrier's Gas Combustion Unit

  • Sungrok Kim;Qianfeng Lin;Jooyoung Son
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.383-384
    • /
    • 2022
  • Gas Combustion Unit (GCU) onboard liquefied natural gas carriers handles boil-off to stabilize tank pressure. There are many factors for LNG cargo operators to take into consideration to determine whether to use GCU or not. Gas consumption of main engine and re-liquefied gas through the Partial Re-Liquefaction System (PRS) are good examples of these factors. Human gas operators have decided the operation so far. In this paper, some deep learning neural network models were developed to provide human gas operators with a decision support system. The models consider various factors specially into GCU operation. A deep learning model with Sigmoid activation functions in input layer and hidden layers made the best performance among eight different deep learning models.

  • PDF

Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers (보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

An Experimental Study on the Effect of Mixture Distribution in the Constant Volume Combustion Chamber on the Combustion Characteristics (정적 연소실내 혼합기 분포가 연소특성에 미치는 영향에 관한 실험적 연구)

  • 이기형;이창희;안용흠
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.10-18
    • /
    • 2004
  • It is well known that the stratified charge combustion has many kind of advantages to combustion characteristics, such as higher thermal efficiency and less CO, NOx levels than conventional homogeneous mixture combustion. Although this combustion can be caused low fuel consumption, it is produced the high unburned hydrocarbon and soot levels because of different equivalence ratio in the combustion chamber. Moreover it has a lot of possibility of low output and misfire if the mixture gas would not be in existence around the spark plug. In this paper, fundamental studies for stratified combustion were carried out using a constant volume combustion chamber. The effect of locally mixture gas distribution according to control the direct injection and premixed injection in the chamber were examined experimentally. In addition, the effects of turbulence on stratified charge combustion process were observed by schlieren photography.

An Experimental Study on the Combustion Behavior of Single Coal-Water Slurry Droplet (석탄-물 혼합물 단일액적의 연소 특성에 관한 실험적 연구)

  • 채재우;조용철;전영남;한영수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2159-2168
    • /
    • 1992
  • Coal-water slurry is considered to have the potential for displacing petroleum used in the existing oil-fired industrial and utility boilers. The combustion of coal-water slurry(CWS) is a complex process and little is known about the detailed mechanism. In this paper the combustion behavior of a single suspended droplet of CWS in hot gas stream was investigated. The effect of coal particle size, water content in droplet, initial droplet size, ambient temperature and oxygen fraction in ambient gas were studied. The results are as follows; (1) Increasing the oxygen fraction in ambient gas considerably reduced the char combustion time. (2) The variation of water content and coal particle size in droplet showed little effect on the combustion behavior. (3) In the relatively high temperature ambient gas, the water evaporation time became shorter and the combustion process was stable.

Start of Combustion Detection Method for Gasoline Homogeneous Charge Compression Ignition Engine (가솔린 균일 예혼합 압축착화 엔진의 착화시점 검출)

  • Choe, Doo-Won;Lee, Min-Kwang;SunWoo, Myoung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.151-158
    • /
    • 2008
  • Gasoline Homogeneous Charge Compression Ignition (HCCI) combustion is a new combustion concept. Unlike the conventional internal combustion engine, the premixed fuel mixture with high residual gas rate is auto-ignited and burned without flame propagation. There are several operating factors which affect HCCI combustion such as start of combustion (SOC), residual gas fraction, engine rpm, etc. Among these factors SOC is a critical factor in the combustion because it affects exhaust gas emissions, engine power, fuel economy and combustion characteristics. Therefore SOC of gasoline HCCI should be controlled precisely, and SOC detection should be preceded SOC control. This paper presents a control oriented SOC detection method using 50 percent normalized difference pressure. Normalized difference pressure is defined as the normalized value of difference pressure and difference pressure is difference between the in-cylinder firing pressure and the motoring pressure. These methods were verified through the HCCI combustion experiments. The SOC detection method using difference pressure provides a fast and precise SOC detection.

Numerical Study on Spontaneous Combustion in Coal Stockpile (저탄장에서의 석탄 자연발화에 관한 수치 해석적 연구)

  • HONG, JINPYO;KIM, JAEKWAN;CHI, JUNHWA;PARK, SUKWOON;SEO, DONGGYUN;LEE, JINHYANG
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.6
    • /
    • pp.721-728
    • /
    • 2017
  • In this work, an one-dimensional analysis on spontaneous combustion in a coal stockpile was conducted using a commercial software $gPROMS^{(R)}$ based on assumption suggested by Arioy and Akgun. According to them, it is assumed that there is temperature difference between the surface of coal particle and the gas surrounded around the particle, and it is also assumed that the velocity of the gas is constant and thus oxygen is fed to the stockpile with same velocity. The higher temperature zone is formed to the surface of the coal stockpile at the initial phase and it became deepen as time is taken. Finally it was found that the temperature difference between coal particle and the gas was calculated as $57^{\circ}C$ and spontaneous combustion have not been occurred during 6 months since coal was piled in the stock.

A Study on Dynamic Characteristics of Gas Centered Swirl Coaxial Injector with Acoustic Excitation by Varying Momentum Flux Ratio (운동량 플럭스 비의 변화에 따른 기체 중심 스월 동축형 분사기의 기체 가진 동특성 연구)

  • Lee, Jungho;Park, Gujeong;Yoon, Youngbin
    • Journal of ILASS-Korea
    • /
    • v.20 no.3
    • /
    • pp.168-174
    • /
    • 2015
  • Combustion instability is critical problem in developing liquid rocket engine. There have been many efforts to solve this problem. In this study, the method was sought through the injector as part of these efforts to suppress combustion instability. If the injector can suppress the disturbance coming from the supply line as a kind of buffer it will serve to reduce combustion instability. Especially we target at gas propellant oscillation in gas-centered swirl coaxial injector. The phenomenon is simulated with acoustic excitation of speaker. The film thickness response at injector exit was measured by using a liquid film electrode. Also the response of spray to the disturbance was observed by high-speed photography. Gas-liquid momentum flux ratio and the frequency of feeding gas oscillation were changed to investigate the effect of these experimental parameters. The trend of response by varying these parameters and the cause of weak points was studied to suggest the better design of injector for suppressing combustion instability.

An Investigation of Combustion Emission Characteristics of Kerosene Fan Heater with Addition of Water Droplets by Ultrasonic Atomizer (초음파 수첨가 연소에 의한 석유 홴 히터의 배기가스 특성 고찰)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.44-53
    • /
    • 1999
  • This study is concerned with the emission characteristics of kerosene fan heater, which is burned with kerosene and water droplets simultaneously in the burner, in order to prohibit the emissions of harmful exhaust gas and reduce smell caused by incomplete combustion, and the addition of water droplets to the conventional kerosene fan heater was performed by ultrasonic atomizer. For the investigation of this study, the measurement of exhaust gas components and exhaust gas temperature was carried out by using an automatic combustion gas analyser and $NO_x$ analyser, and the measurement of consumption weight of oil and water was obtained by using electric digital balance. Consequently, according as the water percent weight ratio of about $21{\sim}23%$ was supplied for this study, it was found that the combustion-generated $NO_x$ and CO emissions were reduced very largely, but the emissions of $O_2\;and\;CO_2$ and the temperature of exhaust gas were not changed.

  • PDF

A Study on the Combustion Characteristics over Pd/cordierite Catalyst (Pd/cordierite 촉매상에서 메탄의 연소 특성 고찰)

  • Cho, Won-Ihl;Oh, Young-Sam;Park, Dal-Ryung;Baek, Young-Soon;Pang, Hyo-Sun;Mok, Young-Il
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.34-40
    • /
    • 1997
  • This study aims to investigate the application possibility on natural gas in relation to the catalytic combustion of methane on Pd/cordierite catalyst which is currently used as an automobile converter catalyst. The surface area of the catalyst tested was determined to be about 18.7㎡/g and to keep stable condition in structure at mid-high temperatures. The activation energy for methane combustion reaction was estimated to be 19.2 kcal/mol and a hysterisis on the catalyst activity was observed in terms of the catalyst deactivation as the reaction temperature was varied for the methane combustion. On Pd/cordierite catalyst, The characteristics of methane combustion were studied as functions of space velocity and air/fuel ratios below 700$^{\circ}C$.

  • PDF

Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler (가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF