• 제목/요약/키워드: Gap sensor

검색결과 403건 처리시간 0.027초

SOI 슬롯 광 도파로 기반 단일 및 삽입-분기 채널 링-공진형 바이오·케미컬 집적광학 센서의 제원에 대한 감도 해석 (Sensitivity Analysis for Specifications of Silicon-on-Insulator (SOI) Slot Optical Waveguide-based Single and Add-drop Channel Ring-resonant Biochemical Integrated Optical Sensors)

  • 장재식;정홍식
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.107-114
    • /
    • 2022
  • The effects of ring radius and coupling spacing on the free spectral range (FSR), full width at half maximum (FWHM), quality factor, and sensitivity of single-channel and add-drop channel slot ring resonators were systematically investigated using FIMMPROP and PICWAVE numerical software. The single-channel ring resonator exhibited better characteristics, namely, a wider FSR and narrower FWHM compared with the add-drop structure; thus, it was evaluated to be more suitable for biochemical sensors. The FSR, FWHM, quality factor, and sensitivity for a single channel ring resonator with a radius of 59.4 ㎛ and coupling gap of 0.5 ㎛ were 2.4 nm, 0.087 nm, 17677, and 550 [nm/RIU], respectively.

End-point control of a flexible arm under base fluctuation

  • Chonan, Seiji;Sato, Hidehiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.600-605
    • /
    • 1989
  • A theoretical study is presented for the end-point holding control of a one-link flexible arm, whose base is subjected to a lateral fluctuation. The arm is clamped on a rigid hub mounted directly on the shaft of d.c. servomoter. The tip position is measured by a gap sensor fixed in space isolated from the system vibration. The arm is controlled so as to make the end point stay precisely at its initial position even if the base is fluctuated.

  • PDF

Numerical Investigation on Bottom Gap of Micro Flow Sensor

  • Abdullah Mohd Zulkiefly;Kouta T.;Kamijo Takuma;Yamamoto Makoto;Honami Shinji;Kamiunten Shouji
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.103-104
    • /
    • 2003
  • PDF

스핀들회전오차 종합적성능평가 기술에 관한 연구 (Combined Error Performance of Machine Tool spindle)

  • 신현장;이석원;박희재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.333-337
    • /
    • 1996
  • The spindle directly affects parts accuracy during machining, or work piece in machine tools. In this paper a comprehensive study is performed combined mr performance of machine tool spindle. The developed methology has been practically applied to a spindle of machine tools.

  • PDF

Embodiment of all-optical switching phenomena on a GaAs waveguide

  • 이상재
    • 센서학회지
    • /
    • 제5권5호
    • /
    • pp.85-95
    • /
    • 1996
  • Based on the transmission of coupled gap solitons in nonlinear periodic media, we present an all-optical switching scheme which has a novel architecture and principle. The proposed switch with an extremely small switching element can be realized on a semiconductor waveguide. We here investigate the switching performance with a GaAs waveguide in order to give criteria for the experimental realization of the all-optical switching phenomena. We also suggest a variation of an index-matching scheme to solve the technical problem such as the input-energy coupling into a periodic waveguide.

  • PDF

병렬판구조를 이용한 소형 6축 힘/토크센서의 설계 및 특성평가 (Design and evaluation of small size six-axis force/torque sensor using parallel plate sturcture)

  • 주진원;나기수;김갑순
    • 대한기계학회논문집A
    • /
    • 제22권2호
    • /
    • pp.353-364
    • /
    • 1998
  • This paper describes the design processes and evaluation results of a small-sized six-axis force/torque sensor. The new six-axis force/torque sensor including S-type structure has been developed using a parallel plate structure as a basic sensing element. In order tominimize coupling errors, the location of strain gages has been determined based on the finite element analysis and the connections of strain gages have been made such that the bridge circuit with 4 strain gages becomes balanced. Several design modifications result in a similar strain sensitivity for six-axis forces and moments, and the reduced coupling errors of 2.6% FS between each forces and moments. Calibration test results show that the six-axis load cell developed which has light weight of 135g and the maximum capacities of 196 N in forces and 19.6 N.m in moments is estimated to be within 7.1% FS in coupling error.

VCM(voice coil motor)를 이용한 3차원 나노 형상 측정 시스템 (3-D Nano Topology Measurement using VCM)

  • 정종규;염우섭;박기환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1439-1443
    • /
    • 2007
  • In this paper, vibration reduction techniques of a voice coil motor (VCM) actuator are presented for AFM imaging system. The damping coefficient of the actuator driven by VCM with a flexure hinge is quite low and it cause the about 30dB peak amplitude response at the resonance frequency. To decrease this peak response, we design and apply elliptical band-stop filters to xy and z axis VCM actuator. Frequency response of each actuator with filter is measured to verify the effect of the filters. As a sensor, capacitive sensor is used. Vibration reduction rate of the xy actuator with the filter is also measured while real AFM scanning condition. As another method, closed loop control with the capacitive sensor is applied to the xy axis actuator to add an electrical damping effect and vibration reduction rate measured. These vibration reduction rates with each method are compared. In the case of z axis actuator, the frequency response of force (gap) control loop is measured. For comparison, the frequency response using a conventional PID controller is also obtained. Finally, the AFM image of a standard grid sample is measured with the designed controller to analyze the effect in the AFM imaging.

  • PDF

탄소섬유의 게이지 계수 측정 및 센서 응용 (Measurement of a gauge factor of a carbon fiber and its application to sensors)

  • 김지관;박창신;이동원
    • 센서학회지
    • /
    • 제17권3호
    • /
    • pp.162-167
    • /
    • 2008
  • In this paper we report on the electrical properties of carbon fiber which is an attractive material for strain gauges and can also be applied to resonating micro sensors. The carbon fibers used in this research was manufactured from polyactylonitrile (PAN). The fabricated carbon fibers had about $10\;{\mu}m$ in length and several centimeters in length. We employed a micro structure to measure electrical properties of the carbon fiber. The measured electrical resistivity of the carbon fibers were about $3{\times}10^{-3}{\Omega}{\cdot}cm$ A gauge factor of the carbon fiber is also observed with the same system and it was about 400, depending on the structure of the carbon fiber. For the sensor applications of the carbon fiber, it is selectively placed between the gap of Al electrodes using a dielectrophoresis method. When the carbon fiber is resonated by a piezoelectric ceramic, resistance change at a variety of resonance mode was observed through an electrical system.

Effect of the Calcination Temperature and Li(I) Doping on Ethanol Sensing Properties in p-Type CuO Thin Films

  • Choi, Yun-Hyuk
    • 한국재료학회지
    • /
    • 제29권12호
    • /
    • pp.764-773
    • /
    • 2019
  • The gas response characteristic toward C2H5OH has been demonstrated in terms of copper-vacancy concentration, hole density, and microstructural factors for undoped/Li(I)-doped CuO thin films prepared by sol-gel method. For the films, both concentrations of intrinsic copper vacancies and electronic holes decrease with increasing calcination temperature from 400 to 500 to 600 ℃. Li(I) doping into CuO leads to the reduction of copper-vacancy concentration and the enhancement of hole density. The increase of calcination temperature or Li(I) doping concentration in the film increases both optical band gap energy and Cu2p binding energy, which are characterized by UV-vis-NIR and X-ray photoelectron spectroscopy, respectively. The overall hole density of the film is determined by the offset effect of intrinsic and extrinsic hole densities, which depend on the calcination temperature and the Li(I) doping amount, respectively. The apparent resistance of the film is determined by the concentration of the structural defects such as copper vacancies, Li(I) dopants, and grain boundaries, as well as by the hole density. As a result, it is found that the gas response value of the film sensor is directly proportional to the apparent sensor resistance.

후판의 자동 다층용접을 위한 아크센서 시스템 개발에 관한 연구 (A Study on Development of Arc Sensor System for Automatic Multi-pass Welding of Thick Plate)

  • 문현준;김종희;최주호;김형식
    • Journal of Welding and Joining
    • /
    • 제13권4호
    • /
    • pp.122-131
    • /
    • 1995
  • An automatic welding equipment for thick plates requires the capability of the seam tracking of the weld line which often includes misalignment of the workpiece and variation of groove width. In this study, an automatic welding equipment and control algorithms based on the arc sensor were proposed for the GMA welding of thick plates which had misalignment and gap variation. The developed system being constituted with 5 axis can be automatically controlled by computer and also automnatically set the welding conditions such as welding current, and voltage. The proposed algorithms for the seam tracking in multi-pass welding of the thick plates were constituted as follows : the detection of weaving-end point for findng the variation of groove width, the control of welding velocity for acquiring a constant thickness deposition of weld metal, and the calculation of groove width and height of an arbitrary pass in the multi-pass weld. As results of the application of the system, it was revealed that the system had a good capability in seam tracking and made an excellent weld quality in V groove butt joint.

  • PDF