• 제목/요약/키워드: Gap Sensor

검색결과 403건 처리시간 0.025초

AE센서를 이용한 유중 코로나방전점 위치 및 주파수 영역 검출 (Location and Frequency Domain Detection of Corona Discharge Point in Oil Using AE Sensor)

  • 이상우;김성훈;김인식;김기채;박원주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.127-131
    • /
    • 1999
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane electrode was analyzed to determine the proper ultrasonic sensor. We also examined the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] AC high-voltage in oil. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were found to be 130[kHz] by the fast fourier transform. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages. Also the detection of corona discharge point location by AE signals was found to be possible by using two sensors.

  • PDF

Micromagnetic Modeling of Spin-valve MR Head with Synthetic Antiferromagnet (SyAF)

  • Tahk, Y.W;Lee, K.J;Lee, T.D
    • Journal of Magnetics
    • /
    • 제7권2호
    • /
    • pp.55-58
    • /
    • 2002
  • MR transfer behaviors of the permanent magnet biased spin valve MR sensors with SyAF (synthetic antiferromagnet) layers were studied by micromagnetics modeling. For narrow track MR heads, various height to width ratios were considered together with strength of permanent magnets which stabilities the free layed As the MR sensor width is reduced to $0.12 \mu{m}$, sensor height less than 0.09 ${\mu}{\textrm}{m}$ is needed to show good linearity and the Mr.t of permanent magnets smaller than 0.2 memu/$cm^2$ is sufficient for the domain stabilization. The conditions for single domain behavior of the free layer were also investigated through optimizing the biasing strength of permanent magneto the shield gap and the aspect ratio of MR sensor.

Pt 및 Pt-$SnO_2$를 전극으로 하는 SiC 쇼트키 다이오드의 CO 가스 감응 특성 (A study on CO gas sensing Characteristics of Pt-SiC $SnO_2$-pt-SiC Schottky Diodes)

  • 김창교;노일호;양성준;이재홍;이주헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.805-808
    • /
    • 2002
  • A carbon monoxide gas sensor utilizing Pt-SiC, Pt-SnO2-SiC diode structure was fabricated. Since the operating temperature for silicon devices in limited to 200oC, sensor which employ the silicon substrate can not at high temperature. In this study, CO gas sensor operating at high temperature which utilize SiC semiconductor as a substrate was developed. Since the SiC is the semiconductor with wide band gap. the sensor at above $700^{\circ}C$. Carbon monoxide-sensing behavior of Pt-SiC, Pt-SnO2-SiC diode is systematically compared and analyzed as a function of carbon monoxide concentration and temperature by I-V and ${\Delta}$I-t method under steady-state and transient conditions.

  • PDF

센서 융합을 이용한 MAF 공정 특성 분석 (Characterization of Magnetic Abrasive Finishing Using Sensor Fusion)

  • 김설빔;안병운;이성환
    • 대한기계학회논문집A
    • /
    • 제33권5호
    • /
    • pp.514-520
    • /
    • 2009
  • In configuring an automated polishing system, a monitoring scheme to estimate the surface roughness is necessary. In this study, a precision polishing process, magnetic abrasive finishing (MAF), along with an in-process monitoring setup was investigated. A magnetic tooling is connected to a CNC machining to polish the surface of stavax(S136) die steel workpieces. During finishing experiments, both AE signals and force signals were sampled and analysed. The finishing results show that MAF has nano scale finishing capability (upto 8nm in surface roughness) and the sensor signals have strong correlations with the parameters such as gap between the tool and workpiece, feed rate and abrasive size. In addition, the signals were utilized as the input parameters of artificial neural networks to predict generated surface roughness. Among the three networks constructed -AE rms input, force input, AE+force input- the ANN with sensor fusion (AE+force) produced most stable results. From above, it has been shown that the proposed sensor fusion scheme is appropriate for the monitoring and prediction of the nano scale precision finishing process.

실시간 맥박 및 혈압 측정을 위한 폴리머 기판 압력센서 개발 (Development of Pressure Sensor on Polymer Substrate for Real-time Pulse and Blood Pressure Measurements)

  • 김진태;김성일;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제26권9호
    • /
    • pp.669-676
    • /
    • 2013
  • In this study, we introduce a polymer(polyimide) based pressure sensor to measure real-time heart beat and blood pressure. The sensor have been designed with consideration of skin compatibility of material, cost effectiveness, manufacturability and wireless detection. The designed sensor was composed of inductor coils and an air-gap capacitor which generate self-resonant frequency when electrical source is applied on the system. The sensor was obtained with metalization, etching, photolithography, polymer adhesive bonding and laser cutting. The fabricated sensor was shaped in circular type with 10mm diameter and 0.45 mm thickness to fit radial artery. Resonant frequencies of the fabricated sensors were in the range of 91~96 MHz on 760 mmHg pressurized environment. Also the sensor has good linearity without any pressure-frequency hysteresis. Sensitivity of the sensor was 145.5 kHz/mmHg and accuracy was less than 2 mmHg. Real-time heart beat measurement was executed with a developed hand-held measurement system. Possibility of real-time blood pressure measurement was showed with simulated artery system. After installation of the sensor on skin above radial artery, simple real blood pressure measurement was performed with 64 mmHg blood pressure variation.

무선 전력 구동 센서 태그 내장형 온도센서의 설계 (Design of a Wireless Self-Powered Temperature Sensor for UHF Sensor Tags)

  • 김현식;조정현;김시호
    • 대한전자공학회논문지SD
    • /
    • 제44권10호
    • /
    • pp.1-6
    • /
    • 2007
  • UHF RFID 태그에 내장하여, 유비쿼터스 센서 네트워크의 구성 기초 소자로 활용 가능한 온도센서 회로를 제안하였다. UHF RFID 내장을 위해 1.5 V 이하의 저전압, 5 uW의 동작 소비 전력소비, $0.1\;^{\circ}C/bit$의 해상도를 설계 목표로 하였다. 온도센서의 구성은 PTAT 전류 발생기, 기준 전류와 전압 발생 회로, 시그마 델타 변환기, 디지털 카운터로 구성되어 있다. 제안된 온도센서는 $0.1\;^{\circ}C/bit$의 해상도를 목표로 설계하였지만, 시뮬레이션에서는 11-bit 출력에서 최대 $0.23\;^{\circ}C/bit$의 해상도를 얻을 수 있었다. 0.25 um CMOS 공정을 설계 및 제작하였고, 전원 전압은 1.5 V, 칩의 면적은 $0.32\;{\times}\;0.22\;mm$이고 동작주파수는 2 MHz이다. 제작된 온도센서의 해상도를 측정한 결과 8-bit 출력에서 평균 $4\;^{\circ}C/bit$로 측정되었다.

스퍼터링 법으로 증착한 CdS 박막의 광전도도 특성 평가

  • 허성기;장동미;최명신;안준구;성낙진;윤순길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.81-81
    • /
    • 2008
  • Applications of CdS films in this study are to exhibit a high conductivity when they are exposed at light with visible wavelength and sequentially to show a low conductivity in dark state. For this purpose, CdS films should have a high photosensitivity, still maintaining a high conductivity at a visible light. In this study, CdS films were prepared at room temperature on glass substrates by rf magnetron sputtering. In order to increase the photo-conductivity in visible light, various defect levels should be located within the CdS band gap. In order to nucleate the defect sites within the CdS band gap, CdS films were deposited on glass substrates at room temperature using various $H_2$/(Ar+$H_2$) flow ratios by an rf magnetron sputtering. Through the investigation of the structural and photoconductive properties of CdS films by an addition of hydrogen, the relationship between photo- and dark-resistance in CdS films was investigated in detail. 200-nm-thick CdS films for photoconductive sensor applications were prepared at various $H_2$/(Ar+$H_2$) flow ratios on glass substrates at room temperature by rf magnetron sputtering. Sulfur concentration in CdS films crystallized at room temperature with (002) preferred orientation depends directly on the hydrogen atmosphere and the surface roughness of the films gradually increases with increasing hydrogen atmosphere. Films deposited at 8% of $H_2$/(Ar+$H_2$) exhibit an abrupt decrease of dark- and photo-resistance, showing a low photo-sensitivity ($R_{dark}/R_{photo}$). Onthe other hand, films deposited at a hydrogen atmosphere of 42% exhibit a photo-sensitivity of $5\times10^3$, maintaining a photo-resistance of an approximately $2\times10^4\Omega$/square. The dark- and photo-resistance values of CdS films were related with a composition, surface roughness, and defect sites within the band gap.

  • PDF

NOX 가스 검출 특성을 이용한 MWCNT/ZnO 복합체 필름 가스 센서의 메커니즘 분석 (The Analysis of Mechanism for the Gas Sensor of MWCNT/ZnO Composites Film Using the NOX Gas Detection Characteristics)

  • 손주형;김현수;박용서;장경욱
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.188-192
    • /
    • 2018
  • In this study, we fabricated an $NO_X$ gas sensor using a composite film of multi-walled carbon nanotubes (MWCNT)/zinc oxide (ZnO). Carbon nanotubes (CNTs) show good electronic conductivity and chemical-stability, and zinc oxide (ZnO) is a wide band gap semiconductor with a large exciton binding energy. Gas sensors require characteristics such as high speed, sensitivity, and selectivity. The fabricated gas sensor was used to detect $NO_X$ gas at different $NO_X$ concentrations. The sensitivity of the gas sensor increased with increasing gas concentrations. Additionally, while changing the temperature inside the chamber containing the MWCNT/ZnO gas sensor, we obtained the sensitivity and normalized responses for detecting $NO_X$ gas in comparison to ZnO and MWCNT film gas sensors. From the experimental results, we confirmed that the gas sensor sensing mechanism was enhanced in the composite-film gas-sensor and that the electronic interaction between MWCNT and ZnO contributed to the improved sensor performance.

무선센서네트워크 기반의 웨어러블 센서노드에서 3축 가속도 신호의 단채널 전송과 심전도 노이즈 제거에 대한 연구 (A Research for Removing ECG Noise and Transmitting 1-channel of 3-axis Accelerometer Signal in Wearable Sensor Node Based on WSN)

  • 이승철;정완영
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.137-144
    • /
    • 2011
  • Wireless sensor network(WSN) has the potential to greatly effect many aspects of u-healthcare. By outfitting the potential with WSN, wearable sensor node can collects real-time data on physiological status and transmits through base station to server PC. However, there is a significant gap between WSN and healthcare. WSN has the limited resource about computing capability and data transmission according to bio-sensor sampling rates and channels to apply healthcare system. If a wearable node transmits ECG and accelerometer data of 4 channel sampled at 100 Hz, these data may occur high loss packets for transmitting human activity and ECG to server PC. Therefore current wearable sensor nodes have to solve above mentioned problems to be suited for u-healthcare system. Most WSN based activity and ECG monitoring system have been implemented some algorithms which are applied for signal vector magnitude(SVM) algorithm and ECG noise algorithm in server PC. In this paper, A wearable sensor node using integrated ECG and 3-axial accelerometer based on wireless sensor network is designed and developed. It can form multi-hop network with relay nodes to extend network range in WSN. Our wearable nodes can transmit 1-channel activity data processed activity classification data vector using SVM algorithm to 3-channel accelerometer data. ECG signals are contaminated with high frequency noise such as power line interference and muscle artifact. Our wearable sensor nodes can remove high frequency noise to clear original ECG signal for healthcare monitoring.

MWCNT/ZnO 복합체 필름을 이용한 가스센서의 NOx가스 검출 특성 분석 (The Analysis of NOx Gas Detection Characteristics for the Gas Sensor Using the MWCNT/ZnO Composites Film)

  • 김현수;이원재;박용서;장경욱
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.312-316
    • /
    • 2016
  • In this study, we fabricated $NO_x$ gas sensor by using multi-walled carbon nanotubes(MWCNT)/zinc oxide(ZnO) composite film. Carbon nanotubes (CNTs) have good electronic, chemical-stability, and sensitivity characteristics. And zinc oxide (ZnO) is a wide band gap and large exciton binding energy semiconductor. In particular, gas sensors require characteristics such as high speed, sensitivity, and selectivity. The fabricated gas sensor was used to detect $NO_x$ gas for different values of the $NO_x$ gas concentrations. The gas sensor that absorbed$NO_x$ gas molecules showed a increasing in resistance. The sensitivity of the gas sensor was increased by increasing the gas concentrations. Additionally, while changing the temperature inside the chamber for the MWCNT/ZnO composite film gas sensor, we obtained the sensitivity. And the comparison analysis to ZnO film gas sensor for detecting $NO_x$ gas. From the experiment result, we confirmed improvement of $NO_x$ gas detection characteristics using the MWCNT/ZnO composite film.