• Title/Summary/Keyword: Gamma-spectroscopy

Search Result 297, Processing Time 0.025 seconds

Status of Development of Pyroprocessing Safeguards at KAERI (한국원자력연구원 파이로 안전조치 기술개발 현황)

  • Park, Se-Hwan;Ahn, Seong-Kyu;Chang, Hong Lae;Han, Bo Young;Kim, Bong Young;Kim, Dongseon;Kim, Ho-Dong;Lee, Chaehun;Oh, Jong-Myeong;Seo, Hee;Shin, Hee-Sung;Won, Byung-Hee;Ku, Jeong-Hoe
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.191-197
    • /
    • 2017
  • The Korea Atomic Energy Research Institute (KAERI) has developed a safeguards technology for pyroprocessing based on the Safeguards-By-Design (SBD) concept. KAERI took part in a Member-State Support Program (MSSP) to establish a pyroprocessing safeguards approach. A Reference Engineering-scale Pyroprocessing Facility (REPF) concept was designed on which KAERI developed its safeguards system. Recently the REPF is being upgraded to the REPF+, a scaled-up facility. For assessment of the nuclear-material accountancy (NMA) system, KAERI has developed a simulation program named Pyroprocessing Material Flow and MUF Uncertainty Simulation (PYMUS). The PYMUS is currently being upgraded to include a Near-Real-Time Accountancy (NRTA) statistical analysis function. The Advanced Spent Fuel Conditioning Process Safeguards Neutron Counter (ASNC) has been updated as Non-Destructive Assay (NDA) equipment for input-material accountancy, and a Hybrid Induced-fission-based Pu-Accounting Instrument (HIPAI) has been developed for the NMA of uranium/transuranic (U/TRU) ingots. Currently, performance testing of Compton-suppressed Gamma-ray measurement, Laser-Induced Breakdown Spectroscopy (LIBS), and homogenization sampling are underway. These efforts will provide an essential basis for the realization of an advanced nuclear-fuel cycle in the ROK.

Detection Characteristics of TL, ESR and DNA Comet for Irradiated Peanuts by Origins (TL, ESR및 DNA Comet분석에 의한 원산지별 땅콩의 방사선 조사 검지 특성)

  • 이은영;정재영;조덕조;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.6
    • /
    • pp.1076-1081
    • /
    • 2001
  • Gamma-irradiated peanuts, Korean and Chinese origins, were investigated on detection properties by thermoluminescence (TL), electron spin resonance (ESR), and DNA comet assay (single cell gel electrophoresis). TL measurement showed that the non-irradiated sample revealed a glow curve with low intensity at about 25$0^{\circ}C$, while the irradiated samples showed higher intensity around at 18$0^{\circ}C$. TL ratio (TL$_1$/TL$_2$) of area for TL$_1$ glow curve to TL$_2$ was below 0.05 for the non-irradiated sample and 0.2 or more for the irradiated ones, thus identifying each other. ESR spectroscopy for the irradiated peanuts using outer skin showed negligible signals induced by irradiation, indicating ESR is little applicable to the detection of irradiated peanuts. In DNA comet assay, the non-sample had no or very short tails, whereas the irradiated samples revealed the cells with long tails. Significance in the increase of their lengths depending on irradiation dose (r=0.761/Korean, r=0.768/Chinese) was also found. There was no remarkable difference in detection properties by origins of samples in all determinations, It is concluded that TL analysis or DNA comet assay is suitable for detection of irradiated peanuts and a combined method is recommendable for enhancing the reliability of detection results.

  • PDF

Development of Simple and Rapid Radioactivity Analysis for Thorium Series in the Products Containing Naturally Occurring Radioactive Materials (NORM) (천연방사성물질(NORM)을 함유한 가공제품 내 토륨계열 방사능 평가를 위한 간단/신속 분석법 개발)

  • Yoo, Jaeryong;Park, Seyoung;Yoon, Seokwon;Ha, Wi-Ho;Lee, Jaekook;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • Background: It is necessary to analyze radioactivity of naturally occurring radioactive materials (NORM) in products to ensure radiological safety required by Natural Radiation Safety Management Act. The pretreatments for the existing analysis methods require high technology and time. Such destructive pretreatments including grinding and dissolution of samples make impossible to reuse products. We developed a rapid and simple procedure of radioactivity analysis for thorium series in the products containing NORM. Materials and Methods: The developed method requires non-destructive or minimized pretreatment. Radioactivity of the product without pretreatment is initially measured using gamma spectroscopy and then the measured radioactivity is adjusted by considering material composition, mass density, and geometrical shape of the product. The radioactivity adjustment can be made using scaling factors, which is derived by radiation transport Monte Carlo simulation. Necklace, bracelet, male health care product, and tile for health mat were selected as representative products for this study. The products are commonly used by the public and directly contacted with human body and thus resulting in high radiation exposure to the user. Results and Discussion: The scaling factors were derived using MCNPX code and the values ranged from 0.31 to 0.47. If radioactivity of the products is measured without pretreatment, the thorium series may be overestimated by up to 2.8 times. If scaling factors are applied, the difference in radioactivity estimates are reduced to 3-24%. Conclusion : The developed procedure in this study can be used for other products with various materials and shapes and thus ensuring radiological safety.

Detection Characteristics of Gamma-Irradiated Korean Medicinal Herbs by Using PSL, TL, and ESR (PSL, TL 및 ESR 분석에 의한 감마선 조사 한약재의 검지 특성)

  • Yang, Hee-Sun;Park, Yong-Dae;Jin, Chang-Hyun;Choi, Dae-Seong;Chung, Hyung-Wook;Byun, Myung-Woo;Jeong, Il-Yun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1529-1533
    • /
    • 2008
  • The detection characteristics of gamma-irradiated ($0{\sim}10.0\;kGy$) medicinal herbs (Platycodon grandiflorum, Acanthopanax chiisanensis) were investigated by photostimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR). The results of the PSL, a first screening method in comparison with the TL, showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples, while the non-irradiated samples yielded photon counts less than 700 counts/60 s (negative). The TL was also applied for the detection method of irradiated medicinal herbs and showed that the non-irradiated sample revealed a glow curve with a low intensity, while the irradiated samples showed a higher intensity. These results were normalized by re-irradiating the mineral grains with a irradiation dose of 1.0 kGy, and a second glow curve was recorded. The ratio of the intensity of the first glow curve ($TL_1$) to that after the normalization dose ($TL_2$) was determined and compared with the recommended threshold values. TL ratio ($TL_1/TL_2$) was below 0.007 for the non-irradiated sample and higher than 0.1 for all irradiated samples (above 1.0 kGy). ESR spectroscopy revealed specific signals (6.065 mT) derived from free radicals in cellulose containing irradiated medicinal herbs. The P. grandiflorum showed clearer signals than A. chiisanensis. From the results of our studies, the PSL, TL, and ESR determinations were found to be suitable for the detection of irradiated medicinal herbs such as P. grandiflorum and A. chiisanensis.

Removal Characteristic of Arsenic by Sand Media Coated with both Iron-oxide and Manganese-oxide (산화철 및 산화망간이 동시에 코팅된 모래 매질을 이용한 비소오염 제거특성 연구)

  • Kim, Byeong-Kwon;Min, Sang-Yoon;Chang, Yoon-Young;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.473-482
    • /
    • 2009
  • In this study, iron and manganese coated sand (IMCS) was prepared by mixing Joomoonjin sand with solutions having different molar ratio of manganese ($Mn^{2+}$) and iron ($Fe^{3+}$). Mineral type of IMCS was analyzed by X-ray diffraction spectroscopy. Removal efficiency of arsenic through As(III) oxidation and As(V) adsorption by IMCS having different ratio of Mn/Fe was evaluated. The coated amount of total Mn and Fe on all IMCS samples was less than that on sand coated with iron-oxide alone (ICS) or manganese-oxide alone (MCS). The mineral type of the manganese oxide on MCS and iron oxides on ICS were identified as ${\gamma}-MnO_2$ and mixture of goethite and magnetite, respectively. The same mineral type was appeared on IMCS. Removed amount As(V) by IMCS was greatly affected by the content of Fe rather than by the content of Mn. Adsorption of As(V) by IMCS was little affected by the presence of monovalent and divalent electrolytes. However a greatly reduced As(V) adsorption as observed in the presence of trivalent electrolyte such as $PO_4\;^{3-}$. As(III) oxidation efficiency by MCS in the presence of NaCl or $NaNO_3$ was two times greater than that in the presence of $PO_4\;^{3-}$. Meanwhile a greater As(III) oxidation efficiency was observed by IMCS in the presence of $PO_4\;^{3-}$. This was explained by the competitive adsorption between phosphate and arsenate on the surface of IMCS.

Nuclear Imaging Evaluation of Galactosylation of Chitosan (핵의학 영상을 이용한 chitosan의 galactosylation 효과에 대한 평가)

  • Jeong, Hwan-Jeong;Kim, Eun-Mi;Park, In-Kyu;Cho, Chong-Su;Kim, Chang-Guhn;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.253-258
    • /
    • 2004
  • Purpose: Chitosan has been studied as a non-viral gene delivery vector, drug delivery carrier, metal chelator, food additive, and radiopharmaceutical, among other things. Recently, galactose-graft chitosan was studied as a non-viral gene and drug delivery vector to target hepatocytes. The aim of this study was to investigate the usefulness of nuclear imaging for in vivo evaluation of targeting the hepatocyte by galactose grafting. Methods and Materials: Galactosyl methylated chitosan (GMC) was produced by methylation to lactobionic acid coupled chitosan. Cytotoxicity of $^{99m}Tc$-GMC was determined by MTT assay. Rabbits were injected via their auricular vein with $^{99m}Tc$-GMC and $^{99m}Tc$-methylated chitosan (MC), the latter of which does not contain a galactose group, and images were acquired with a gamma camera equipped with a parallel hole collimator. The composition of the galactose group in galactosylated chitosan (GC), as well as the tri-, di-, or mono-methylation of GMC, was confirmed by NMR spectroscopy. Results: The results of MTT assay indicated that $^{99m}Tc$-GMC was non-toxic. $^{99m}Tc$-GMC specifically accumulated in the liver within 10 minutes of injection and maintained high hepatic uptake. In contrast, $^{99m}Tc$-MC showed faint liver uptake. $^{99m}Tc$-GMC scintigraphy of rabbits showed that the galactose ligand principally targeted the liver while the chitosan functionalities led to excretion through the urinary system. Conclusion: Bioconjugation with a specific ligand endows some degree of targetability to an administered molecule or drug, as in the case of galactose for hepatocyte in vivo, and evaluating said targetabililty is a clear example of the great benefit proffered by nuclear imaging.

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.