• Title/Summary/Keyword: Gamma transmission

Search Result 171, Processing Time 0.028 seconds

On-line Gamma Monitoring System for Environmental Radiation Measurement around KAERI-site (KAERI 부지 주변의 환경선량 측정을 위한 온라인 감마선량 감시시스템)

  • Lee, Chang-Woo;Park, Doo-Won;Lee, Won-Yun;Choi, Yong-Ho;Hong, Kwang-Hee;Kim, Sam-Rang;Lee, Hyun-Duk;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.147-156
    • /
    • 1994
  • On-line gamma monitoring system around KAERI-site was set up to monitor the radiation fluctuations in environment. Data on gamma exposure rates measured by the ionication chamber in the monitoring posts are transmitted to a computer of central control station with. radio telemetry transmission modem and monitored in real time. Radio telemetry transmission system is economical and reliable on handling and storing of data. This monitroing system can triger an early warning system in the event of abnormal radiation levels.

  • PDF

VLC Wireless Data Transmission of High Luminance LED Irradiated by the High Dose-Rate Gamma-Ray (고 선량 감마선 조사에 따른 고휘도 LED의 가시광 무선 데이터 전송)

  • Cho, Jai-Wan;Choi, Young-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.996-1000
    • /
    • 2010
  • In order to apply VLC (visible light communication) in harsh environment of nuclear power plant in-containment building, the high luminance LEDs, which are key components of the VLC system, have been gamma irradiated at the dose rate of 4 kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced coloration effect in the high luminance LED bulb made of acryl or plastic material was observed. In the VLC wireless data transmission experiment using the high luminance LEDs irradiated by high dose rate gamma-ray, the radiation induced coloration effect of the high luminance LED bulb extended the communication distance compared to non-irradiated LEDs.

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

Influence of Atmospheric Turbulence Channel on a Ghost-imaging Transmission System

  • Wang, Kaimin;Wang, Zhaorui;Zhang, Leihong;Kang, Yi;Ye, Hualong;Hu, Jiafeng;Xu, Jiaming
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • We research a system of compressed-sensing computational ghost imaging (CSCGI) based on the intensity fluctuation brought by turbulence. In this system, we used the gamma-gamma intensity-fluctuation model, which is commonly used in transmission systems, to simulate the CSCGI system. By setting proper values of the parameters such as transmission distance, refractive-index structure parameter, and sampling rates, the peak signal-to-noise ratio (PSNR) performance and bit-error rate (BER) performance are obtained to evaluate the imaging quality, which provides a theoretical model to further research the ghost-imaging algorithm.

Feasibility Study of Gamma Ray Transmission Technique in Distillation Column Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 감마선 투과계측 증류탑 진단기술의 타당성 연구)

  • Moon, Jinho;Kim, Jongbum;Park, Jang Guen;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.115-119
    • /
    • 2013
  • The density profile measurement technology by gamma transmission has been widely used to diagnose processes in the field of refinery and petrochemical industry. This technology can reveal a clue and position of abnormal phenomenon of industrial processes during their operation. In this paper, the feasibility of the gamma transmission technology for detecting changes in the amount of fluid in a distillation column was evaluated by using Monte Carlo simulations. The simulations assumed that $^{60}Co$ (1.17, 1.33 MeV) sources and NaI (Tl) detectors (${\Phi}5{\times}5cm$) are located in opposite sides of a column and it concurrently moves in vertical direction. To determine the dependency of a spatial resolution on aperture size of a collimator, the simulation model for a tray in a column were simulated with the aperture sizes of 1 and 2 cm. The thickness of the high density area including a tray and fluid was 7.6 cm in the simulation. The spatial resolution of the tray was 8.2 and 8.5 cm, respectively. As a result, it was revealed that the conventional density profile measurement technique is not able to show the deviation of liquid level on a tray in a column.

A Study on the Precipitation Behavior of Disordered ${\gamma}$ Phase in an $L1_2$ Ordered ${\gamma}^{\prime}-Ni_3(Al,Ti)$ Phase ($L1_2$${\gamma}^{\prime}-Ni_3(Al,Ti)$ 규칙상 중에 불규칙 ${\gamma}$상의 석출거동에 관한 연구)

  • Han, Chang-Suk
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.19 no.5
    • /
    • pp.249-256
    • /
    • 2006
  • Structural studies have been performed on precipitation hardening found in $L1_2$ ordered ${\gamma}^{\prime}-Ni_3(Al,Ti)$ alloys using transmission electron microscopy. A uniform solid solution of ${\gamma}^{\prime}-L1_2$ ordered phase supersaturated with Ni can be obtained by solution annealing in a suitable temperature range. The ${\gamma}^{\prime}$ phase hardens appreciably by the fine precipitation of disordered ${\gamma}$. The shape of ${\gamma}$ precipitates formed during aging is initially spherical or round-cubic and grow into platelets as aging proceeds. High resolution electron microscopy revealed that the ${\gamma}$ precipitates are perfectly coherent with the matrix ${\gamma}^{\prime}$ as long as the ${\gamma}$-precipitates are plates. The loss of coherency initiates by the introduction of dislocations at the ${\gamma}/{\gamma}^{\prime}$ interface followed by the step formation at the dislocations. The ${\gamma}$ precipitates become globular after the loss of coherency. The strength of ${\gamma}^{\prime}-Ni_3(Al,Ti)$ increases over the temperature range of experiment by the precipitation of fine ${\gamma}$ particles. The peak temperature where a maximum strength was obtained shifted to higher temperature.

Mechanical properties and radiation shielding performance in concrete with electric arc furnace oxidizing slag aggregate

  • Lim, Hee Seob;Lee, Han Seung;Kwon, Seung Jun
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.4
    • /
    • pp.363-371
    • /
    • 2019
  • In this study, physical properties of normal concrete, magnetite concrete, EAF concrete, and EAF concrete with added iron powder were evaluated and a feasibility of radiation shielding is also evaluated through irradiation tests against X-rays and gamma-rays. While the unit weight of EAF concrete (3.21 t/㎥) appeared lower than that of magnetite concrete (3.50 t/㎥), the results in compressive strength of EAF concrete were greater than those in magnetite and normal concrete. While the radiation transmission rate of normal concrete reaches 26.0% in the X-ray irradiation test, only 6.0% and 9.0% of transmission rate were observed in magnetite concrete and linear relationship with unit volume weight and radiation shielding. In the gamma-ray irradiation test, the performance of EAF and magnetite concretes appeared to be similar. Through the results on the excellent physical properties and radiation shielding performance a potential applicability of EAF concrete to radiation shielding was verified.

Double Opportunistic Transmit Cooperative Relaying System with GSC in Rayleigh Fading Channels

  • Kim, Nam-Soo;Lee, Ye-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.270-275
    • /
    • 2010
  • In a conventional opportunistic transmit (COT) cooperative relaying system, only the relays that receive signal-to-noise ratio (SNR) from the source and that exceed the threshold transmit to the destination. The COT system, however, only considers the SNR of the source-relay (S-R) path regardless that the SNR of the relay-destination (R-D) path is the opportunistic transmission condition. For that reason, it is not guaranteed that all the transmitted signals from relays exceed the threshold at the destination. Therefore we propose a double opportunistic transmit (DOT) cooperative relaying system - when both of the received SNR from a source and from a destination exceed the threshold, the relay transmits to the destination. It is shown that the proposed DOT system reduces power consumption by 6.9, 20.9, 32.4, and 41.4 % for K =3, 5, 7, and 9, respectively under the given condition of $P_{out}=1{\times}10^{-3}$ and $\overline{\gamma}_{SR}/\Gamma_{SR}$=30 dB, compared to the COT system. We noticed that the performance of the DOT system is superior to that of the COT system for the identical number of active transmit relays under the same condition of the normalized average SNR of $\overline{\gamma}_{RD}/\Gamma_{RD}$.

A Study on the Strength Characteristics of $L1_{2}-Ni_{3}Al$ Intermetallic Compound ($L1_{2}-Ni_{3}Al$ 금속간화합물의 강도특성에 관한 연구)

  • Han, Chang-Suk;Chun, Chang-Hwan;Han, Seung-Oh
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • Structural studies have been performed on precipitation hardening found in $Ni_{3}Al$ based ordered alloys using transmission electron microscopy (TEM). Tilt experiments by the weak-beam method were made to obtain some information concerning the cross slip mechanism of the superlattice dislocation. The strength of ${\gamma}'-Ni_3$(Al,Ti) increases over the temperature range of experiment by the precipitation of fine $\gamma$ particles. The peak temperature where a maximum strength was obtained shifted to higher temperature. Over the whole temperature range, the interaction between dislocation and $\gamma$ precipitates is attractive. On the temperature range of 773 K to 973 K, the dislocations in ${\gamma}'$ matrix move on (111) primary slip plane. When the applied stress is removed, the dislocations make cross slip into (010) plane, while those in $\gamma$ precipitates remain on the (111) primary slip plane. The increase of high temperature strength in ${\gamma}'-Ni_3$(Al,Ti) containing $\gamma$ precipitates is due to the restraint of cross slip of dislocations from (111) to (010) by the dispersion of disordered $\gamma$ particles.

Determination of Lattice Parameters and Observation of Lattice Misfits on Rene 80 Cast Blades (Rene 80 주조블레이드에서 격자상수의 결정 및 격자어긋남의 관찰)

  • An, Seong-Uk
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.515-520
    • /
    • 1993
  • By the real use of Rene 80 cast blades at high temperature ${\gamma}^{\prime}$ precipitates in the matrix(${\gamma}$) mainly due to the operating temperature. These precipitates play main role for strenthening of the blades. Generally known that dislocation density increases due to ${\gamma}-{\gamma}^{\prime}$ mismatch by the generation and growth of the precipitates, because the lattice parameter of ${\gamma}^{\prime}$ is higher than that of ${\gamma}$. These lattice parameters of ${\gamma}$ and ${\gamma}^{\prime}$ are determined through the CBED(Convergent Beam Electron Diffraction) method by STEM(Scanning Transmission Electron Microscope) in this work. And also studied, whether and how much the dislocation density increases by the generation and growth of the precipitates.

  • PDF