Study of Magnetic Property of Fe-N Nanoparticle Using Mössbauer Spectroscopy (뫼스바우어 분광기법을 이용한 Fe-N 나노입자의 자기특성연구)

  • Oh, Sei-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.76-80
    • /
    • 2007
  • Three nano-sized Fe-N particle samples synthesized by Chemical Vapor Condensation (CVC) were analyzed using $M\"{o}ssbauer$ spectroscopy, XRD and BET. The synthesized nanoparticles consisted of ${\epsilon}-Fe_{2.12}N,\;{\gamma}'-Fe_4N,\;{\alpha}-Fe\;and\;{\gamma}-Fe.\;{\gamma}'-Fe_4N$ was mainly formed at the low decomposition temperature. With increasing decomposition temperature, the phase was changed to ${\gamma}-Fe$ via ${\epsilon}-Fe_{2.12}N$. For synthesizing Fe-N phases, this study implies that the low decomposition temperature is better than high temperature during Chemical Vapor Condensation.

Fabrication and Evaluation of Spectroscopic Grade Quasi-hemispherical CdZnTe Detector

  • Beomjun Park;Kyungeun Jung;Changsoo Kim
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.2
    • /
    • pp.85-90
    • /
    • 2024
  • Background: This study focuses on the fabrication and characterization of quasi-hemispherical Cd0.9Zn0.1Te (CZT) detector for gamma-ray spectroscopy applications, aiming to contribute to advancements in radiation measurement and research. Materials and Methods: A CZT ingot was grown using the vertical Bridgman technique, followed by proper fabrication processes including wafering, polishing, chemical etching, electrode deposition, and passivation. Response properties were evaluated under various external bias voltages using gamma-ray sources such as Co-57, Ba-133, and Cs-137. Results and Discussion: The fabricated quasi-hemispherical CZT detector demonstrated sufficient response properties across a wide range of gamma-ray energies, with sufficient energy resolution and peak distinguishability. Higher external bias voltages led to improved performance in terms of energy resolution and peak shape. However, further improvements in defect properties are necessary to enhance detector performance under low bias conditions. Conclusion: This study underscores the efficacy of quasi-hemispherical CZT detector for gamma-ray spectroscopy, providing valuable insights for enhancing their capabilities in radiation research field.

Study in Background Reduction for the Neutron Induced Prompt Gamma-ray Spectroscopy

  • Song, Byoung-Chul;Jee, Kwang-Yong;Park, Yong-Joon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.433-433
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system measures the prompt gamma-ray, emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many elements in either solid or liquid wastes. A NIPS facility has been developed in Nuclear Chemistry Research Division, at Korea Atomic Energy Research Institute (KAERI) with the aim of analyzing the major component elements in both aqueous and solid samples.(omitted)

  • PDF

Band gap energy and photocurrent splitting for CdIn2Te4 crystal by photocurrent spectroscopy ($CdIn_2Te_4$ 결정의 띠간격 에너지의 온도 의존성과 가전자대 갈라짐에 대한 연구)

  • Hong, Kwang-Joon;Kim, Do-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.121-122
    • /
    • 2006
  • Single crystal of $CdIn_2Te_4$ were grown by the Bridgman method without using seed crystals. From photocurrent measurements, its was found that three peaks, A, B, and C, correspond to the instrinsic transition from the valence band states of ${\Gamma}_7$(A), ${\Gamma}_6$(B), and ${\Gamma}_7$(C) to the conducton band states of ${\Gamma}_6$, respectively. Crystal field splitting and spin orbit splitting were found to be at 0.2360 eV and 0.1119 eV, respectively, from found to be photocurrent spectroscopy.

  • PDF

Neutron Induced Capture Gamma Spectroscopy Sonde Design and Response Analysis Based on Monte Carlo Simulation (Monte Carlo 시물레이션에 기초한 포획모드 중성자-감마 스펙트럼 존데 설계 및 반응 분석)

  • Won, Byeongho;Hwang, Seho;Shin, Jehyun;Kim, Jongman;Kim, Ki-Seog;Park, Chang Je
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.154-161
    • /
    • 2015
  • For efficiently designing neutron induced gamma spectroscopy sonde, Monte Carlo simulation is employed to understand a dominant location of thermal neutron and classify the formation elements from the energy peak of capture gamma spectrum. A pulsed neutron generator emitting 14 MeV neutron particles was used as a source, and flux of thermal neutron was calculated from the twelve detectors arranged at each 10 cm intervals from the source. Design for reducing borehole effects using shielding materials was also applied to numerical sonde model. Moreover, principal elements and quantities of numerical earth models were verified through the energy spectrum analysis of capture gamma detected from a gamma detector. These results can help to enhance the signal-to-noise ratio, and determine an optimal placement of capture gamma detectors of neutron induced gamma spectroscopy sonde.

Basic characterization of uranium by high-resolution gamma spectroscopy

  • Choi, Hee-Dong;Kim, Junhyuck
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.929-936
    • /
    • 2018
  • A basic characterization of uranium samples was performed using gamma- and X-ray spectroscopy. The studied uranium samples were eight types of certified reference materials with $^{235}U$ enrichments in the range of 1-97%, and the measurements were performed over 24 h using a high-resolution and high-purity planar germanium detector. A general peak analysis of the spectrum and the $XK_{\alpha}$ region of the uranium spectra was carried out by using HyperGam and HyperGam-U, respectively. The standard reference sources were used to calibrate the spectroscopy system. To obtain the absolute detection efficiency, an effective solid angle code, EXVol, was run for each sample. Hence, the peak activities and isotopic activities were determined, and then, the total U content and $^{234}U$, $^{235}U$, and $^{238}U$ isotopic contents were determined and compared with those of the certified reference values. A new method to determine the model age based on the ratio of the activities of $^{223}Ra$ and $^{235}U$ in the sample was studied, and the model age was compared with the known true age. In summary, the present study developed a method for basic characterization of uranium samples by nondestructive gamma-ray spectrometry in 24 h and to obtain information on the sample age.

Investigation of a novel on-site U concentration analysis method for UO2 pellets using gamma spectroscopy

  • Lee, Haneol;Park, Chan Jong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1955-1963
    • /
    • 2021
  • As the IAEA has applied integrated safeguards and a state level approach to member states, the importance of national inspection has increased. However, the requirements for national inspection for some member states are different from the IAEA safeguards. In particular, the national inspection for the ROK requires on-site U concentration analysis due to a domestic notification. This research proposes an on-site U concentration analysis (OUCA) method for UO2 pellets using gamma spectroscopy to satisfy the domestic notification requirement. The OUCA method calculates the U concentration of UO2 pellets using the measured net X-ray counts and declared 235U enrichment. This research demonstrates the feasibility of the OUCA method using both MCNP simulation and experiment. It simulated and measured the net X-ray counts of different UO2 pellets with different U concentrations and 235U enrichments. The simulated and measured net X-ray counts were fitted to polynomials as a function of U concentration and 235U enrichment. The goodness-of-fit results of both simulation and experiment demonstrated the feasibility of the OUCA method.

Detection of Iron Phases Presents in Archaeological Artifacts by Raman Spectroscopy

  • Barbosa, A.L.;Jimenez, C.;Mosquera, J.A.
    • Corrosion Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.60-67
    • /
    • 2018
  • The compounds associated with corrosion, in metallic archaeological samples of carbon steel of insular origin were evaluated to establish their degree of deterioration and structural damage against air pollution. The iron phases present in samples of archaeological artifacts were detected by Raman spectroscopy and confocal Raman microcopy. These samples mainly exhibited ing mainly ${\beta}$-FeO(OH) type goethite oxyhydroxides and small amounts of akaganeite ${\alpha}$-FeO(OH) lepidocrocite ${\gamma}$-FeO(OH) due to dominant chloride in a marine environment and non-stoichiometric oxyhydroxides Fe (II + / III +) as indicators of early corrosion. Some parts showed the presence of magnetic maghemite indicating high corrosion. ${\gamma}$-FeO(OH) is a precursor of phases associated with advanced marine corrosion. By studying its decomposition by Raman spectroscopy, it was synthesized with the following sequence: ${\gamma}-FeO(OH){\rightarrow}{\alpha}-FeO(OH)+{\gamma}-FeO(OH)$, ${\rightarrow}{\gamma}-Fe_2O_3+Fe_3O_4$. Ferric compounds provided evidence for the effect of intensity of laser on them, constituting a very useful input for the characterization of oxidation of iron in this type of artifacts. Thus, destructive analysis techniques should be avoided in addition to the use of small amounts of specimen.

Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy (LYSO 섬광체를 이용한 감마선 분광용 광섬유 방사선 센서의 개발)

  • Han, Ki-Tek;Yoo, Wook-Jae;Shin, Sang-Hun;Jeon, Da-Yeong;Park, Jang-Yeon;Park, Byung-Gi;Lee, Bong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.287-292
    • /
    • 2012
  • A fiber-optic radiation sensor was fabricated using a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer for gamma-ray spectroscopy. As an inorganic scintillator of the sensing probe, a LYSO crystal was used. In this study, we obtained the relationship between the photon counts of the fiber-optic radiation sensor and the activity of the radioactive isotope. In addition, the gamma-ray energy spectra were also measured using a fiber-optic radiation sensor to discriminate species of gamma-ray emitters.