• Title/Summary/Keyword: Gamma scan

Search Result 105, Processing Time 0.026 seconds

The Analysis of radioactivity Concentration in drainage when using a radioactive Iodine (방사성옥소 사용 시 배수 중 방사능농도 분석)

  • Lee, Kyung-Jae;Sul, Jin-Hyung;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • Purpose With regard to the use of radioiodine in domestic medical institution, the case of exceeding the allowance of nuclear safety Act about radioactive concentration in drainage was found. Through understanding the cause of exceeding case and analyzing radioactive concentration in drainage, evaluating the relationship of the public waters in surroundings and usefulness. Materials and Methods From November 1, 2014 to April 30th, 2015, the research is aiming at domestic twenty hospitals for six months. By using a HPGe gamma-ray spectrometer(Canberra DSA-1000) and GENIE-2000 Analysis software for comparative analysis, measuring a radioactive concentration of radioiodine in drainage. Consequently, we confirm the excess of radioactive concentration of radioiodine in seven medical institutions. Results Conducting a survey of twenty hospitals and average radioactive concentration of radioiodine in drainage appears $42,100Bq/m^3$. The features of domestic hospitals where show a high radioactive concentration are a number of medical treatment patient when using radioactive iodine and the absence of private rest room. During I-131 whole body scan, the pretreatment procedure of urinating is considered emission of residual Iodine. In public waters, the cause of exceeding detect on radioactive concentration in drainage suppose a diagnostic radioactive iodine. Conclusion We confirm the importance of enhanced education, providing a safety control instructions and installing a private rest rooms for patients who injected a low capacity radioiodine. Also, constructing institutional and legal management system is considered about the Emission management standard in drainage.

Determination of radiolysis products in Tri-Octyl Amine by high performance liquid chromatography-mass spectrometer (HPLC-MS에 의한 Tri-Octyl Amine(TOA)의 방사선 분해산물 정량)

  • Yang, Han-Beom;Lee, Eil-Hee;Moon, Hyung-Sil
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.201-205
    • /
    • 2005
  • Tri-octyl amine (TOA) is used in solvent extraction process for radioactive waste. This compound may be degraded to di-octyl amine (DOA), mono-octyl amine (MOA) by radioactive materials. Amount of TOA, DOA and MOA in TOA must be monitored because they production of these compounds means degradation of which leads to a decrease in the extraction yield. Retention behavior for TOA, DOA and MOA are studied with Phenomenex LUNA-$C_{18}$ ($4.6mm{\times}25cm$) analytical column and $CH_3OH:H_2O$ (50 mmol $CH_3COONH_4$) eluent by liquid chromatography. Optimum condition for these compounds is $CH_3OH:H_2O$ (50 mmol $CH_3COONH_4$) = 85 : 15 ratio. TOA, DOA and MOA compounds is well separated within 20 minute. Dynamic range is $30{\sim}160{\mu}g/mL$ for TOA, $5{\sim}100{\mu}g/mL$ for DOA and $0.1{\sim}5{\mu}g/mL$ for MOA, respectively. The detection limit are $0.1{\mu}g/mL$ for TOA, $1{\mu}g/mL$ for DOA (in SCAN mode) and $0.1{\mu}g/mL$ for MOA (in SIM mode) in this system with $20{\mu}L$ sample loop.

A STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS BY USING OF POTENTIOSTATIC POLARIZATION METHOD (정전압 분극곡선법에 의한 아말감의 부식 거동에 관한 연구)

  • Shin, Dong-Hoon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.39-49
    • /
    • 1986
  • The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.

  • PDF

ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF DENTAL AMALGAM IN ARTIFICIAL SALIVA (인공타액에서 아말감의 부식거동에 관한 전기화학적 연구)

  • Kim, Yeoung-Nam;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.221-235
    • /
    • 1988
  • The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.

  • PDF

Quantitative Evaluation of the Remaining Hepatic Function after Surgery in Patients with Hepatic Cancer using Deconvolution Technique of Tc-99m DISIDA SCAN (Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 간암 환자의 수술 후 잔여 간 기능의 정량적 평가)

  • Kim, Deok-Won;Kim, Su-Chan;Yun, Seok-Jin;Lee, Jong-Du;Kim, Byeong-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.301-306
    • /
    • 1997
  • Surgical removal of hepatic cancerous tissues have been widely performed due to its early detection. However, a patient can not survive if excessive hepatic tissues were removed. Therefore, quantitative evaluation of remaining hepatic function after surgery is a really important factor for surgeon. the currently used ICG Rmax and Lidocaine clearance tests have disadvantages such as tedium, complexity, and inability to estimate remaining hepatic function after surgery. While HEF has advantages such as simplicity, quickness, nonivasiveness, and quantification, its reliability has been doubtful. Thus, the program for calculation of HEF has been developed from serial gamma camera image data. And we compared the reliability of HEF with ICG Rmax and Lidocaine clearance test using 6normal and 18 abnormal rabbits with damaged livers. The correlation coefficient of HEF to ICG Rmax and MEGX was 0.91, 0.94, respectively. I was also found that the HEFs of normal and abnormal hepatic tissues was higher than 100% and lower than 80%, respectively. Thus we confirmed that HEF can be a good indicator distinguishing between abnormal tissues and normal ones. Finally, we could conclude that patients would survive if both the pre-and the post-operative HEF were greater than 60%.

  • PDF

Total En Bloc Thoracic and Lumbar Spondylectomy for Non-Small Cell Lung Cancer with Favorable Prognostic Indicators : Is It Merely Indicated for Solitary Spinal Metastasis?

  • Park, Jong-Hwa;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.431-435
    • /
    • 2014
  • A fifty-year-old female non-smoker with no other specific medical history visited our institute. She complained of axial back pain with no other neurological deficit. Chest X-ray, chest computed tomography (CT) scan, CT-guided needle aspiration biopsy, whole-body positron emission tomography, spine CT and spine magnetic resonance image findings suggested NSCLC with epidermal growth factor receptor (EGFR) mutation, multiple brain metastases, and two isolated metastases to the T3 and L3 vertebral bodies. She underwent chemotherapy with gefitinib ($Iressa^{TM}$) for NSCLC and gamma knife surgery for multiple brain metastases. We performed a two-staged, total en bloc spondylectomy of the T3 and L3 vertebral bodies based on several good prognostic characteristics, such as the lack of metastases to the appendicular bone, good preoperative performance status, and being an excellent responder (Asian, never-smoker and adenocarcinoma histology) to EGFR inhibitors. Improved axial back pain after the surgery enabled her to walk with the aid of a thoracolumbosacral orthosis brace on the third postoperative day. Her Karnofsky performance status score (KPS) was 90 at the time of discharge and has been maintained to date 3 years after surgery. In selected NSCLC patients with good prognostic characteristics, we suggest that locally curative treatment such as total en bloc spondylectomy or radiosurgery should be emphasized to achieve longer term survival for the selected cases.

3D Reconstruction Using Segmentation of Myocardial SPECT Images (SPECT 심근영상의 영상분할을 이용한 3차원 재구성)

  • Jung, Jae-En;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.5-10
    • /
    • 2009
  • Myocardial imaging in SPECT (Single Photon Emission Computed tomography) scan of the gamma-ray emitting radiopharmaceuticals to patients after intravenous radiopharmaceuticals evenly spread in the heart region of interest by recording changes in the disease caused by a computer using the PSA test is to diagnose. Containing information on the functional myocardial perfusion imaging is a useful way to examine non-invasive heart disease, but the argument by noise and low resolution of the physical landscape that is difficult to give. For this paper, the level of myocardial imaging by using the three algorithms to split the video into 3-D implementation of the partitioned area to help you read the proposed plan. To solve the difficulty of reading level, interest in using the sheet set, partitioned area of the left ventricle was ranked the partitioned area was modeled as a 3-D images.

  • PDF

3D Reconstruction Using Segmentation of Myocardial SPECT (SPECT 심근영상의 영상분할을 이용한 3차원 재구성)

  • Jung, Jae-Eun;Lee, Jun-Haeng;Choi, Seok-Yoon;Lee, Sang-Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2240-2245
    • /
    • 2010
  • Myocardial imaging in SPECT (Single Photon Emission Computed tomography) scan of the gamma-ray emitting radiopharmaceuticals to patients after intravenous radiopharmaceuticals evenly spread in the heart region of interest by recording changes in the disease caused by a computer using the PSA test is to diagnose. Containing information on the functional myocardial perfusion imaging is a useful way to examine non-invasive heart disease, but the argument by noise and low resolution of the physical landscape that is difficult to give. For this paper, the level of myocardial imaging by using the three algorithms to split the video into 3-D implementation of the partitioned area to help you read the proposed plan. To solve the difficulty of reading level, interest in using the sheet set, partitioned area of the left ventricle was ranked the partitioned area was modeled as a 3-D images.

Design and Implementation of Hand-Held Inspection Device for High Performance Mobile TFT LCD/OLED Module (고성능 모바일 TFT LCD/OLED 모듈을 위한 헨드헬드 검사장비 설계 및 구현)

  • Moon, Seung-Jin;Kim, Hong-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.630-640
    • /
    • 2009
  • The thesis suggests hand-held equipment to overhaul for mobile TFT LCD/OLED module of high-performance. The established module equipment to overhaul could distinguish outputting video data to module for distinguishing flicker, but it is impossible with low system. In this thesis, supporting system could check the various supplement functions from bringing equipment to overhaul without changing design of FPGA or H/W the module various size for equipment to overhaul for module of high-performance coincidently. The system includes hand-held equipment to overhaul, test software embedded and software a base personal computer and have designed to output, save, and certify all contents of module test of hand-held equipment to overhaul to interface universal serial bus. Setting up 9 items that represent for efficient verification of the proposed system have been possible confirmation with TFT LCD/OLED module of high-performance, establishment scan time, creation gamma, changing register, supporting interface, and multi inch modules.

The effects of psychological factors on elderly of depression scale and Electroephalography

  • Kang, Byeong-Woo;Jung, Mi-Hyun;Cho, Byung-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.157-163
    • /
    • 2016
  • Purpose : This study purposed on the understanding of psychology in the elderly women using depression scale and electroephalography. The subjects were thirty elderly women in geriatric care hospital. All participants were elderly women over 65 years old. The subjects signed up with informed consent and they were divided into a normal elderly group, an exercise elderly group and a hospital elderly group. They were randomly assigned with 10 persons. Methods : The study instruments were Geriatric Depression Scale(GDS) and Poly-G-I. Brain wave activity was measured by 'power spectrum analysis' of TeleScan program. Statistic analysis consisted of average, standard deviation, One-way ANOVA and post-hoc Tukey using SPSS 21.0 version. The significance was set at .05. Results : Depression scale results showed that the exercise elderly group were $10.60{\pm}5.36$ points which was the lowest among the three groups. The Normal elderly group was $16.20{\pm}5.59$, and the hospitalized elderly group was $16.70{\pm}6.76$ points. There was no significant difference between the normal elderly group, exercise elderly group and hospitalized elderly group. The hospitalized group showed statistical difference in relative theta power in the area of Fp1, F3, F4, T3, P3 as compared to the normal elderly group and the exercise elderly groups. There was no significant difference between relative beta power and relative gamma power in three groups. Conclusion : Geriatric depressed scale showed no significant difference in each group. This is indicated in the mental problems associated with depression. This indicates a higher level of depression in the hospitalized elderly women, more than in the normal elderly women and exercise elderly women groups.